DON'T WANT TO MISS A THING?

Certification Exam Passing Tips

Latest exam news and discount info

Curated and up-to-date by our experts

Yes, send me the newsletter

Latest VMware 5V0-21.21 Exam Questions and Answers, 2025 Update | SPOTO

SPOTO's latest exam dumps on the homepage, with a 100% pass rate! SPOTO delivers authentic Cisco CCNA, CCNP study materials, CCIE Lab solutions, PMP, CISA, CISM, AWS, and Palo Alto exam dumps. Our comprehensive study materials are meticulously aligned with the latest exam objectives. With a proven track record, we have enabled thousands of candidates worldwide to pass their IT certifications on their first attempt. Over the past 20+ years, SPOTO has successfully placed numerous IT professionals in Fortune 500 companies.
Take other online exams

Question #1
During planned maintenance of a four-node vSAN cluster, an outsourced IT contractor accidentally removed a 2.5" SSD cache disk from one of the vSAN nodes. The storage policy has been configured with FTT=1 RAID 1, and the disk management UI marked the disk group as absent. Which remediation steps should the administrator select to ensure VMs become compliant with the storage policy as soon as possible?
A. replace the SSD cache disk > rescan > add disk back in disk group
B. enter host in maintenance > remove from disk group > shutdown host > replace disk > power on host
C. remove disk group > enter host in maintenance > fully evacuate all data > exit maintenance
D. vSAN Health Check > retest > object health > repair objects immediately
View answer
Correct Answer: A
Question #2
What is the purpose of slack space in vSAN?
A. Increases overall vSAN capacity
B. Allows for maintenance and failure operations
C. Stores vSphere HA heartbeats
D. Provides vSAN analytic data
View answer
Correct Answer: B
Question #3
An architect is tasked to design a VMware Horizon Solution with vSAN. The architect needs to use a solution to host the user’s profile shares in a highly available manner, and it must be guest OS independent Which solution will match these requirements?
A. Cluster out of the box
B. Cluster in a box
C. NFS on vSAN
D. iSCSI on vSAN
View answer
Correct Answer: C
Question #4
An administrator has an absent capacity disk. Which action, if any, should the administrator take to resolve the problem?
A. Wait, and vSAN will rebuild it
B. Replace the faulty disk
C. Replace the faulty host
D. Verify the host is not isolated
View answer
Correct Answer: B
Question #5
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client. Why is this behavior being seen?
A. vSAN network diagnostic mode is not enabled
B. vSAN proactive tests haven?€?t been run yet
C. vSAN performance service is turned off
D. vSAN performance verbose mode is not enabled
View answer
Correct Answer: C
Question #6
A failed storage controller has two vSAN disk groups attached. The components contained on the drives in those disk groups are marked Degraded. vSAN reports that some objects do not comply with their assigned storage policy. How is the compliance issue resolved?
A. Initiate a proactive rebalance to force component repairs
B. Degraded components are repaired after CLOM Repair Delay Timer expires
C. Rebuilding of the degraded components starts immediately
D. Storage policies must be reapplied to all affected objects
View answer
Correct Answer: C
Question #7
A vSAN cluster has this configuration: -4 hosts with 1 disk group per host -Each disk group contains 1 cache device and 7 capacity devices What are two ways to increase the vSAN datastore storage capacity? (Choose two.)
A. Add a host to the cluster
B. Add a cache device to each disk group
C. Add a capacity drive to each disk group
D. Replace a cache device with a larger cache device
E. Add a disk group to each host
View answer
Correct Answer: AE
Question #8
An All-Flash vSAN cluster has 4 nodes with this disk group composition on each host: ? 1 ?— 800 GB SAS SSD ? 6 ?— 3.84 TB SATA SSD An administrator observes that in an All-Flash cluster, the Write Buffer Free Percentage is consistently low. As a result, there is increased latency experienced by the workloads. Which remediation steps will resolve this issue?
A. Add a second disk group with a new cache device and distribute the capacity disks equally
B. Add a second cache device to the same disk group to increase the caching size
C. Modify advanced vSAN configuration parameters to utilize the complete 800 GB for caching
D. Replace the existing cache device with a larger cache device
View answer
Correct Answer: C
Question #9
What is a benefit of using vSphere Distributed Switches in a vSAN network?
A. Simplifies network abstraction
B. Enables network redundancy
C. Supports faster network adapters
D. Provides the ability to adjust the MTU
View answer
Correct Answer: D
Question #10
An administrator is setting up vSAN file services on a vSAN cluster. Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)
A. Forged Transmits
B. Promiscuous Mode
C. DVFiltering
D. Jumbo Frames
E. MacLearning
View answer
Correct Answer: AB
Question #11
Which must be configured by a Kubernetes user allow for dynamic provisioning of container volumes in vSAN using storage policies?
A. ReplicaSet
B. Pod
C. StorageClass
D. ReplicationController
View answer
Correct Answer: C
Question #12
An architect is working with vSAN and setting the fault domains to support FTT=1. How many fault domains will be needed?
A. 2
B. 3
C. 4
D. 1
View answer
Correct Answer: B
Question #13
After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management TraffiC. rather than vmk1 (vSAN TraffiC.. Which step should be taken to resolve this issue?
A. Configure vmk0 with IP address on the same range as that of vmk1
B. Tag the vmk0 for vSAN traffic
C. Configure vmk1 with IP address on the different network than that of vmk0
D. Tag the vmk1 for Witness traffic
View answer
Correct Answer: C
Question #14
Upon checking the latency goal under vSAN performance diagnostics, the vSAN Administrator sees this message displayed: The increase in latency in the vSAN stack might be beyond expected limits. Which two root causes can be identified to help remediate the issue? (Choose two.)
A. vSAN VMKemel portgroup is configured with the “Route based on IP hash” teaming policy
B. vSAN encryption is enabled
C. Large packet losses and retransmissions on the network layer
D. Incorrect sizing of the disk groups capacity disks
E. One or more disk groups are congested
View answer
Correct Answer: CE
Question #15
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?
A. SFTT = 0
B. SFTT = 1
C. PFTT = 1
D. PFTT = 0
View answer
Correct Answer: A
Question #16
An administrator is setting up vSAN file services on a vSAN cluster. Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)
A. Forged Transmits
B. Promiscuous Mode
C. DVFiltering
D. Jumbo Frames
E. MacLearning
View answer
Correct Answer: AB
Question #17
An administrator receives an alert for vCenter being unavailable. With vCenter running on vSAN, the administrator wants to know if any other VMs are impacted. What command can an administrator run to determine the overall health of the vSAN objects?
A. esxcli vsan storage list
B. esxcli vsan cmmds timemachine get
C. esxcli vsan cluster get
D. esxcli vsan health cluster list
View answer
Correct Answer: C

View The Updated Vmware Exam Questions

SPOTO Provides 100% Real Vmware Exam Questions for You to Pass Your Vmware Exam!

View Answers after Submission

Please submit your email and WhatsApp to get the answers of questions.

Note: Please make sure your email ID and Whatsapp are valid so that you can get the correct exam results.

Email:
Whatsapp/phone number: