 Some Successful CCIE Wireless Lab Exam Strategies You Need Know
images

1.1 Same as peter. bidir missing on 7k1, sh no sh lo254 on 7k2 to test rp good

1.2 the same, ping the other 3 devices to test. Ran show run all | sec system on 7Ks and the system QoS was there.

1.3 same When you configure the NVE interface on 5K1 you will get an error. No worries it will be fixed after you configure the other 5K.

1.4 same Allowed VLANs 101-103

1.5 same I Added VLANs name in 5Ks and Bridge domains names in 7Ks

1.6 same 

1.7 same, Ping worked quickly, no int vlan 100 afterward. Vlan Name was OTV-Extension for vlan 100.

S5

same as videos, input BGP peer, extepg subnets. missing IMPORT, /29 OSPF routed int, hello timer,

all of which are well-documented mistakes.

5.3 Same. I did not use the label method. SSH worked fine

5.4 Same.

5.5 Same

5.6 Same

S2 

5.1 ASAv routed mode so no ping tests.

began by fixing bds. I unclicked limit IP to sumnet in bd-inside.

then asav device asso with the VM,

the VM is special and has your own number on it. 

Checked Funtion profile.

Checked interfaces assing in VMware for ASAv

2.2 Changed IPV4 for IP in the filter. After that, the ports were set to nothing. I fixed them.

Put subnet advertised ext in bd-outside, L3out DC1, DC1extepg consume apptodb. Good to go.

DHCP, SPAN all pre config created, just straight to make DHCP relay and span DST/src grps.

DHCP client took the IP after sytemcrl restart network.

S3

same as videos, KVM booted up at speed of light once FSM 100%.

S4

same as videos

dom.attach(vlanpool)

MAXVLANs = 251

for i in range(201,MAXVLANs):

epg.descr=descr[epgname]['epg_descr']

str(i)

dom.infradomain XXXXXXX move

l2int2 set rearrange good

physdomain - vlanpool need manual attaching. note this check it in fabric/pools/domains

cloud center nothing special, just be carefull not to log in the wrong acc

HTTPS was enable in apic.

Note: in the exam, it was mentioned check tenant 100 % and no fault with EPG ( but I got a fault with EPG ) 

to make tenant health 98 to 100 % done this : 

go to fabric > fabric policy > monitoring policy > common policy >

Health score evaluation policy > check: ignore acknowledged faults 

! then acknowledge all the faults tenant score will become 100 % 

Advice:

Read all feedbacks from other mates that already passed. 

I exam do not go fast. Read all questions carefully and especially the naming. 

Do not take anything for granted. Once you finish the exam and even if you feel you do everything well, go back

over all the configuration and checked again. I founded a couple of mistakes while I was double-checking. 

Try to keep until the end of the time exam reviewing.

Thanks to all of those that helped me and I wish you good luck. God bless you. 

Note: There are some candidates from SPOTO passing the CCIE wireless lab certification exam, and our dumps are completely stable. if you are preparing for the exam or have any questions, and you can enquire directly.

More Recommended Articles

1. What Are Some CCIE Lab Boot Camps in 2019?

2. What is the CCIE Data Center Lab? Which Would Be the Best Website to Prepare for It?

3. CCIE Lab Preparation And Soft Skills You Should Master

4. After Experiencing in Cisco Changes in Exam, I Finally Got the CCIE Certified.

5. Which Part of CCIE Lab Exam Version Changes?