لا تريد أن تفوت شيئا؟

نصائح اجتياز امتحان الشهادة

آخر أخبار الامتحانات ومعلومات الخصم

برعاية وحديثة من قبل خبرائنا

نعم، أرسل لي النشرة الإخبارية

خذ اختبارات أخرى عبر الإنترنت

السؤال #1
An engineer troubleshoots a Cisco UCS B-Series environment and discovers that the status of the CNA is degraded in the CLI and the Cisco UCS Manager GUI. What should be done to resolve the issue?
A. nstall the adapter firmware version that is compatible with Cisco UCs Manager
B. eat the blade server correctly in the chassis
C. se the supported adapter on that server model
D. nstall the server air baffles correctly
عرض الإجابة
اجابة صحيحة: A
السؤال #2
After an upgrade, the standby supervisor of the Cisco N9K-C9504 Series Switch fails to boot and displays the message SYSMGR-2-STANDBY_BOOT_FAILED. Which action resolves the issue?
A. eload the standby supervisor from the TFTP server
B. eload the active supervisor from the bootflash
C. eload the active supervisor from the TFTP server
D. eload the standby supervisor from the bootflash
عرض الإجابة
اجابة صحيحة: D
السؤال #3
An engineer is upgrading the Cisco UCS C240 M5 server's firmware using the Non-Interactive Host Upgrade Utility (NIHUU) tool and the Python script. The ISO mapping is configured as CIFS and the mount option parameter is specified in the NIHU configuration file. However, the NIHUU fails to upgrade due to the ISO mapping error. Which action resolves the issue?
A. nter BIOS setup and change the admin password
B. nable TLS 1
C. pdate and activate Cisco IMC firmware using XML API
D. ownload the software from USB flash drive
عرض الإجابة
اجابة صحيحة: B
السؤال #4
A Cisco UCS B-Series Blade Server is configured to boot a VMware ESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected, but the server fails to boot from the SAN. Which action resolves the problem?
A. et the same WWNN pools for vHBA adapters
B. et the same WWPN pools for vHBA adapters
C. et the boot LUN to the highest LUN ID in the storage array
D. et the boot LUN to the lowest LUN ID in the storage array
عرض الإجابة
اجابة صحيحة: D
السؤال #5
Cisco UCS Manager raises a critical error message that indicates that the system has overlapping Ethernet and FCoE VLANs. All of the Ethernet traffic on the overlapping VLANs drops. Which action resolves the issue?
A. odify the VLAN assignment to vNICs
B. hange the PIN groups on the vHBAs
C. odify the FCoE VLAN
D. et the FCoE VLAN as the native VLAN on server uplinks
عرض الإجابة
اجابة صحيحة: C
السؤال #6
An engineer configures role-based access control for the Cisco UCS Manager. UserA must be allowed read-only access to the system. These events occur after the system is implemented:UserA attempts to log in but receives an "Authentication Failed" message.UserB successfully logs in by using an administrator role.Both users use valid LDAP passwords.Which action resolves the issue?
A. nable primary group rules for LDAP providers
B. dd locales to the LDAP group map of UserB
C. ssign a default role policy for remote users
D. dd locales to the LDAP group map of UserB
عرض الإجابة
اجابة صحيحة: C
السؤال #7
A network engineer troubleshoots an issue at a Cisco data center environment with these conditions:The data center has Cisco Nexus 9000 Series Switches running the vPC setup.The gateway of the servers is an HSRP IP address between the VLAN interfaces configured on both Cisco Nexus switches.Some of the client application servers are implementing fast-path forwarding for the return traffic.Those servers are sending the return traffic to the VLAN interface MAC address instead of the HSRP MAC address.The networ
A. eer-gateway
B. rp synchronize
C. eer-switch
D. panning-tre
عرض الإجابة
اجابة صحيحة: A
السؤال #8
An engineer deploys a Cisco fabric network based on spine-leaf architecture. Cisco DCNM has been integrated to support the automation of a virtual network service of a firewall. After integration, the engineer observes that the host traffic does not reach the firewall node. Which action resolves the issue?
A. pdate the host node IP address in DCNM
B. elete the service node IP address in DCNM
C. omplete the service configuration parameters
D. onfigure the required profile for the host network
عرض الإجابة
اجابة صحيحة: D
السؤال #9
An engineer performs a Cisco B-Series firmware upgrade using a host firmware pack and AutoInstall server feature on an adapter. The adapter activation stops at the pending-next-boot state. The issue occurs at the adapter activation stage during the BIOS and adapter update process. Which set of actions resolves the issue?
A. et the Activate status on the adapter to Ready
B. og in to Cisco UCS Manager
C. isable the fabric services
D. evert the BIOS to the prior working version
E. eboot the operating syste
عرض الإجابة
اجابة صحيحة: A
السؤال #10
A network engineer must configure SNMP monitoring on the Cisco Nexus 5000 Series Switch. The engineer issues the SNMP-server user testuser enforcePriv command but receives this message: "Unable to update CLI users database" Which change to permissions for testuser resolves the issue?
A. dd read permission
B. estrict read permission
C. dd write permission
D. estrict write permissio
عرض الإجابة
اجابة صحيحة: C
السؤال #11
A network engineer is implementing the Cisco ACI Fabric and notices that the Leaf-1 switch is registered has an assigned name, but is displayed as inactive in the APIC. After further investigation, it became clear that the leaf switch was recently moved from another Cisco ACI environment. Which action resolves the problem?
A. efine the new TEP address for Leaf-1
B. lean reload the Leaf-1 switch
C. hange the clock offset from low to high between apic1 and Leaf-1
D. odify the ISIS interface peering IP address between apic1 and Leaf-1
عرض الإجابة
اجابة صحيحة: B
السؤال #12
An engineer configures FCoE between a set of ESXi hosts and a Cisco Nexus 5000 Series Switch. The Converged Network Adapter of the host fails to receive the response from the Cisco Nexus device. Also, the VFC interface is in a down state, and the FIP adapter fails to receive 802.1q tagged frames. The host interface is configured for VLAN trunking. Which action resolves the issue?
A. et the bound Ethernet trunk interface to non-FCoE native VLAN
B. ctivate the reception of Xoff pause frames from the server
C. nable the active STP port state on the bound Ethernet interface
D. onfigure the UF link as a spanning-tree edge port
عرض الإجابة
اجابة صحيحة: A
السؤال #13
An engineer troubleshoots a Cisco UCS B-Series environment and discovers that the status of the CNA is degraded in the CLI and the Cisco UCS Manager GUI. What should be done to resolve the issue?
A. nstall the adapter firmware version that is compatible with Cisco UCs Manager
B. eat the blade server correctly in the chassis
C. se the supported adapter on that server model
D. nstall the server air baffles correctly
عرض الإجابة
اجابة صحيحة: A
السؤال #14
After an upgrade, the standby supervisor of the Cisco N9K-C9504 Series Switch fails to boot and displays the message SYSMGR-2-STANDBY_BOOT_FAILED. Which action resolves the issue?
A. eload the standby supervisor from the TFTP server
B. eload the active supervisor from the bootflash
C. eload the active supervisor from the TFTP server
D. eload the standby supervisor from the bootflash
عرض الإجابة
اجابة صحيحة: D
السؤال #15
An engineer is upgrading the Cisco UCS C240 M5 server's firmware using the Non-Interactive Host Upgrade Utility (NIHUU) tool and the Python script. The ISO mapping is configured as CIFS and the mount option parameter is specified in the NIHU configuration file. However, the NIHUU fails to upgrade due to the ISO mapping error. Which action resolves the issue?
A. nter BIOS setup and change the admin password
B. nable TLS 1
C. pdate and activate Cisco IMC firmware using XML API
D. ownload the software from USB flash drive
عرض الإجابة
اجابة صحيحة: B
السؤال #16
A Cisco UCS B-Series Blade Server is configured to boot a VMware ESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected, but the server fails to boot from the SAN. Which action resolves the problem?
A. et the same WWNN pools for vHBA adapters
B. et the same WWPN pools for vHBA adapters
C. et the boot LUN to the highest LUN ID in the storage array
D. et the boot LUN to the lowest LUN ID in the storage array
عرض الإجابة
اجابة صحيحة: D
السؤال #17
Cisco UCS Manager raises a critical error message that indicates that the system has overlapping Ethernet and FCoE VLANs. All of the Ethernet traffic on the overlapping VLANs drops. Which action resolves the issue?
A. odify the VLAN assignment to vNICs
B. hange the PIN groups on the vHBAs
C. odify the FCoE VLAN
D. et the FCoE VLAN as the native VLAN on server uplinks
عرض الإجابة
اجابة صحيحة: C
السؤال #18
An engineer configures role-based access control for the Cisco UCS Manager. UserA must be allowed read-only access to the system. These events occur after the system is implemented:UserA attempts to log in but receives an "Authentication Failed" message.UserB successfully logs in by using an administrator role.Both users use valid LDAP passwords.Which action resolves the issue?
A. nable primary group rules for LDAP providers
B. dd locales to the LDAP group map of UserB
C. ssign a default role policy for remote users
D. dd locales to the LDAP group map of UserB
عرض الإجابة
اجابة صحيحة: C
السؤال #19
An engineer upgrades Cisco UCS firmware from release 3.1(2) to release 3.1(3) using AutoInstall. Both fabric interconnects go offline during the software upgrade installation and issue multiple FSM retries in the DeployPollActivate stage. Which set of actions resolves the issue?
A. cknowledge the error and reboot the primary fabric interconnect
B. lear the startup version of the default infrastructure and server pack
C. pgrade with the Force attribute through AutoInstall
D. nable the management interface monitoring policy on the fabric interconnects
E. ommit the pending fabric interconnect reboot activity
F. ix the rights to 666 with the debug plugin on the primary fabric interconnect
G. ontinue the upgrade on both fabric interconnects
عرض الإجابة
اجابة صحيحة: B
السؤال #20
A network engineer troubleshoots an issue at a Cisco data center environment with these conditions:The data center has Cisco Nexus 9000 Series Switches running the vPC setup.The gateway of the servers is an HSRP IP address between the VLAN interfaces configured on both Cisco Nexus switches.Some of the client application servers are implementing fast-path forwarding for the return traffic.Those servers are sending the return traffic to the VLAN interface MAC address instead of the HSRP MAC address.The networ
A. eer-gateway
B. rp synchronize
C. eer-switch
D. panning-tre
عرض الإجابة
اجابة صحيحة: A

عرض الإجابات بعد التقديم

يرجى إرسال البريد الإلكتروني الخاص بك والواتس اب للحصول على إجابات الأسئلة.

ملحوظة: يرجى التأكد من صلاحية معرف البريد الإلكتروني وWhatsApp حتى تتمكن من الحصول على نتائج الاختبار الصحيحة.

بريد إلكتروني:
رقم الواتس اب/الهاتف: