السؤال #1
Users in an office lost access to a file server following a short power outage. The server administrator noticed the server was powered off. Which of the following should the administrator do to prevent this situation in the future?
A. Connect the server to a KVM
B. Use cable management
C. Connect the server to a redundant network
D. Connect the server to a UPS
عرض الإجابة
اجابة صحيحة: D
السؤال #2
A server is reporting a hard drive S.M.A.R.T. error. When a technician checks on the drive, however, it appears that all drives in the server are functioning normally. Which of the following is the reason for this issue?
A. A S
B. A S
C. A S
D. A S
عرض الإجابة
اجابة صحيحة: C
السؤال #3
A server administrator has noticed that the storage utilization on a file server is growing faster than planned. The administrator wants to ensure that, in the future, there is a more direct relationship between the number of users using the server and the amount of space that might be used. Which of the following would BEST enable this correlation?
A. Partitioning
B. Deduplication
C. Disk quotas
D. Compression
عرض الإجابة
اجابة صحيحة: AD
السؤال #4
A systems administrator is performing maintenance on 12 Windows servers that are in different racks at a large datacenter. Which of the following would allow the administrator to perform maintenance on all 12 servers without having to physically be at each server? (Choose two.)
A. Remote desktop
B. IP KVM
C. A console connection
D. A virtual administration console
E. Remote drive access
F. A crash cart
عرض الإجابة
اجابة صحيحة: B
السؤال #5
A technician is connecting a server’s secondary NIC to a separate network. The technician connects the cable to the switch but then does not see any link lights on the NIC. The technician confirms there is nothing wrong on the network or with the physical connection. Which of the following should the technician perform NEXT?
A. Restart the server
B. Configure the network on the server
C. Enable the port on the server
D. Check the DHCP configuration
عرض الإجابة
اجابة صحيحة: D
السؤال #6
Which of the following DR testing scenarios is described as verbally walking through each step of the DR plan in the context of a meeting?
A. Live failover
B. Simulated failover
C. Asynchronous
D. Tabletop
عرض الإجابة
اجابة صحيحة: AC
السؤال #7
A server in a remote datacenter is no longer responsive. Which of the following is the BEST solution to investigate this failure?
A. Remote desktop
B. Access via a crash cart
C. Out-of-band management
D. A Secure Shell connection
عرض الإجابة
اجابة صحيحة: D
السؤال #8
A server technician has received reports of database update errors. The technician checks the server logs and determines the database is experiencing synchronization errors. To attempt to correct the errors, the technician should FIRST ensure:
A. the correct firewall zone is active
B. the latest firmware was applied
C. NTP is running on the database system
D. the correct dependencies are installed
عرض الإجابة
اجابة صحيحة: A
السؤال #9
A server administrator was asked to build a storage array with the highest possible capacity. Which of the following RAID levels should the administrator choose?
A. RAID 0
B. RAID 1C
D. RAID 6
عرض الإجابة
اجابة صحيحة: B
السؤال #10
Which of the following can be BEST described as the amount of time a company can afford to be down during recovery from an outage?
A. SLA
B. MTBF
C. RTO
D. MTTR
عرض الإجابة
اجابة صحيحة: D
السؤال #11
A server administrator is experiencing difficulty configuring MySQL on a Linux server. The administrator issues the getenforce command and receives the following output: ># Enforcing Which of the following commands should the administrator issue to configure MySQL successfully?
A. setenforce 0
B. setenforce permissive
C. setenforce 1
D. setenforce disabled
عرض الإجابة
اجابة صحيحة: A
السؤال #12
A datacenter technician is attempting to troubleshoot a server that keeps crashing. The server runs normally for approximately five minutes, but then it crashes. After restoring the server to operation, the same cycle repeats. The technician confirms none of the configurations have changed, and the load on the server is steady from power-on until the crash. Which of the following will MOST likely resolve the issue?
A. Reseating any expansion cards in the server
B. Replacing the failing hard drive
C. Reinstalling the heat sink with new thermal paste
D. Restoring the server from the latest full backup
عرض الإجابة
اجابة صحيحة: A
السؤال #13
Which of the following describes the installation of an OS contained entirely within another OS installation?
A. Host
B. Bridge
C. Hypervisor
D. Guest
عرض الإجابة
اجابة صحيحة: A

عرض الإجابات بعد التقديم