{"id":24599,"date":"2026-11-17T17:20:24","date_gmt":"2026-11-17T09:20:24","guid":{"rendered":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html"},"modified":"2026-11-17T17:20:24","modified_gmt":"2026-11-17T09:20:24","slug":"how-to-check-power-supply-status-on-cisco-switch","status":"publish","type":"post","link":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html","title":{"rendered":"How to Check Power Supply Status on Cisco Switch"},"content":{"rendered":"<p>Maintaining uninterrupted network uptime requires verifying that both primary and redundant power supply units (PSUs) are healthy, properly seated, and receiving stable AC or DC input power. Whether you are auditing dual-power redundancy before a maintenance window, calculating rack power draw, or investigating a syslog alarm, Cisco switches provide detailed environmental telemetry through the command-line interface (CLI) and Simple Network Management Protocol (SNMP).<\/p>\n<p>Because command syntax and output fields vary across hardware families\u2014and because engineers frequently confuse chassis power health with Power over Ethernet (PoE) port budgets\u2014knowing the exact commands for your platform is essential. This guide covers the distinction between system and PoE power commands, platform-specific CLI templates for Cisco Catalyst (IOS\/IOS-XE) and Cisco Nexus (NX-OS) switches, step-by-step hardware troubleshooting, SNMP monitoring OIDs, and official command reference specifications.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_17 counter-hierarchy counter-decimal ez-toc-light-blue\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" style=\"display: none;\"><i class=\"ez-toc-glyphicon ez-toc-icon-toggle\"><\/i><\/a><\/span><\/div>\n<nav><ul class=\"ez-toc-list ez-toc-list-level-1\"><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#System_Power_vs_PoE_Power_Commands_and_Status_Definitions\" title=\"System Power vs. PoE Power Commands and Status Definitions\">System Power vs. PoE Power Commands and Status Definitions<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Checking_Power_Supply_Status_on_Cisco_Catalyst_Switches_IOS_and_IOS-XE\" title=\"Checking Power Supply Status on Cisco Catalyst Switches (IOS and IOS-XE)\">Checking Power Supply Status on Cisco Catalyst Switches (IOS and IOS-XE)<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Checking_Power_Supply_Status_and_Wattage_on_Cisco_Nexus_Switches_NX-OS\" title=\"Checking Power Supply Status and Wattage on Cisco Nexus Switches (NX-OS)\">Checking Power Supply Status and Wattage on Cisco Nexus Switches (NX-OS)<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Troubleshooting_Faulty_Bad_or_No_Input_Power_Supply_States\" title=\"Troubleshooting Faulty, Bad, or No Input Power Supply States\">Troubleshooting Faulty, Bad, or No Input Power Supply States<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Step_1_Check_CLI_Administrative_State_and_Syslog_History\" title=\"Step 1: Check CLI Administrative State and Syslog History\">Step 1: Check CLI Administrative State and Syslog History<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Step_2_Inspect_PSU_Fan_and_Temperature_Sensors\" title=\"Step 2: Inspect PSU Fan and Temperature Sensors\">Step 2: Inspect PSU Fan and Temperature Sensors<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Step_3_Verify_Physical_PSU_LED_Indicators\" title=\"Step 3: Verify Physical PSU LED Indicators\">Step 3: Verify Physical PSU LED Indicators<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Step_4_Isolate_Upstream_Cords_PDUs_and_Brownout_Lockups\" title=\"Step 4: Isolate Upstream Cords, PDUs, and Brownout Lockups\">Step 4: Isolate Upstream Cords, PDUs, and Brownout Lockups<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Step_5_Confirm_Hardware_Detection_for_RMA_show_inventory\" title=\"Step 5: Confirm Hardware Detection for RMA (show inventory)\">Step 5: Confirm Hardware Detection for RMA (show inventory)<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Monitoring_Cisco_Switch_Power_Supplies_via_SNMP_OIDs_and_Traps\" title=\"Monitoring Cisco Switch Power Supplies via SNMP OIDs and Traps\">Monitoring Cisco Switch Power Supplies via SNMP OIDs and Traps<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Official_Cisco_Command_Reference_and_Hardware_Documentation_Specifications\" title=\"Official Cisco Command Reference and Hardware Documentation Specifications\">Official Cisco Command Reference and Hardware Documentation Specifications<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"System_Power_vs_PoE_Power_Commands_and_Status_Definitions\"><\/span>System Power vs. PoE Power Commands and Status Definitions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When auditing power on a Cisco switch, you must distinguish between <strong>chassis hardware power<\/strong> (the physical AC\/DC power supply modules feeding the switch backplane) and <strong>Power over Ethernet (PoE) allocation<\/strong> (the DC power delivered over RJ-45 ports to endpoints like IP phones, wireless access points, and cameras). <\/p>\n<p>The following comparison outlines which command family to use based on the layer of power delivery you need to inspect:<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Criteria<\/th>\n<th style=\"text-align: left;\"><code>show env power<\/code> \/ <code>show environment power<\/code><\/th>\n<th style=\"text-align: left;\"><code>show power inline<\/code><\/th>\n<th style=\"text-align: left;\"><code>show power detail<\/code> \/ <code>show stack-power<\/code><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Primary Purpose<\/strong><\/td>\n<td style=\"text-align: left;\">Verifies the physical health and operational state of internal\/replaceable PSUs.<\/td>\n<td style=\"text-align: left;\">Monitors PoE power allocation and draw on individual switch interfaces.<\/td>\n<td style=\"text-align: left;\">Displays chassis power budgets, module consumption, and StackPower pooling.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Target Component<\/strong><\/td>\n<td style=\"text-align: left;\">Power supply bays (<code>1A<\/code>, <code>1B<\/code>, <code>PS1<\/code>, <code>PS2<\/code>) and internal PSU fans.<\/td>\n<td style=\"text-align: left;\">RJ-45 Ethernet ports (<code>Gi1\/0\/1<\/code>, <code>Te1\/0\/1<\/code>, etc.) and powered devices (PDs).<\/td>\n<td style=\"text-align: left;\">Switch backplane, supervisor engines, line cards, fan trays, and power stacks.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Key Metrics Displayed<\/strong><\/td>\n<td style=\"text-align: left;\">PSU Part ID (PID), Serial Number, Status, System Power, PoE Power, Rated Wattage.<\/td>\n<td style=\"text-align: left;\">Available\/Used\/Remaining PoE Watts, Port Admin\/Oper state, Device Class.<\/td>\n<td style=\"text-align: left;\">Instantaneous\/Peak power, budgeted system power, and PSU redundancy mode.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Wattage Meaning<\/strong><\/td>\n<td style=\"text-align: left;\">Rated maximum capacity of the PSU (e.g., <code>715W<\/code> or <code>1100W<\/code>), not live consumption on most Catalyst models.<\/td>\n<td style=\"text-align: left;\">Live or class-allocated wattage drawn by connected PoE endpoints.<\/td>\n<td style=\"text-align: left;\">Actual system draw vs. reserved hardware power budgets.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Typical Use Case<\/strong><\/td>\n<td style=\"text-align: left;\">Confirming dual-PSU redundancy or diagnosing a failed power cord\/PSU.<\/td>\n<td style=\"text-align: left;\">Troubleshooting an access point or IP phone that fails to power on.<\/td>\n<td style=\"text-align: left;\">Capacity planning for modular chassis or Catalyst StackPower rings.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>When interpreting the output of these commands, the switch reports specific operational states for both physical power supplies and PoE interfaces:<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Command Scope<\/th>\n<th style=\"text-align: left;\">Status Value<\/th>\n<th style=\"text-align: left;\">Meaning and Operational Impact<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Chassis PSU (<code>show env power<\/code>)<\/strong><\/td>\n<td style=\"text-align: left;\"><code>OK<\/code> \/ <code>Good<\/code><\/td>\n<td style=\"text-align: left;\">The power supply is detected, receiving valid input voltage, and delivering healthy output power.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Chassis PSU (<code>show env power<\/code>)<\/strong><\/td>\n<td style=\"text-align: left;\"><code>Not Present<\/code><\/td>\n<td style=\"text-align: left;\">The power supply slot is empty (either unpopulated by design or the module cannot be read by the backplane).<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Chassis PSU (<code>show env power<\/code>)<\/strong><\/td>\n<td style=\"text-align: left;\"><code>No Input Power<\/code><\/td>\n<td style=\"text-align: left;\">A PSU is physically inserted in the slot, but no AC\/DC voltage is detected on its power cord.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Chassis PSU (<code>show env power<\/code>)<\/strong><\/td>\n<td style=\"text-align: left;\"><code>Disabled<\/code><\/td>\n<td style=\"text-align: left;\">The PSU is present and has input power, but it has been administratively turned off via the CLI.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Chassis PSU (<code>show env power<\/code>)<\/strong><\/td>\n<td style=\"text-align: left;\"><code>Bad<\/code> \/ <code>Faulty<\/code><\/td>\n<td style=\"text-align: left;\">The power supply is unrecognizable or has suffered an internal hardware fault.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Chassis PSU (<code>show env power<\/code>)<\/strong><\/td>\n<td style=\"text-align: left;\"><code>Fan Faulty<\/code><\/td>\n<td style=\"text-align: left;\">The PSU is generating power, but its internal cooling fan has failed, risking thermal shutdown.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>PoE Port (<code>show power inline<\/code>)<\/strong><\/td>\n<td style=\"text-align: left;\"><code>on<\/code> \/ <code>off<\/code><\/td>\n<td style=\"text-align: left;\"><code>on<\/code> indicates PoE is actively delivered to a connected device; <code>off<\/code> indicates no PoE device is active.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>PoE Port (<code>show power inline<\/code>)<\/strong><\/td>\n<td style=\"text-align: left;\"><code>fault<\/code> \/ <code>power-deny<\/code><\/td>\n<td style=\"text-align: left;\"><code>fault<\/code> indicates a short circuit or IEEE discovery error; <code>power-deny<\/code> means the switch lacks sufficient remaining PoE budget to power the port.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Takeaway:<\/strong> Always use <code>show env power<\/code> (or <code>show environment power<\/code>) to validate physical PSU hardware and redundancy, and reserve <code>show power inline<\/code> for port-level PoE budget checks.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Checking_Power_Supply_Status_on_Cisco_Catalyst_Switches_IOS_and_IOS-XE\"><\/span>Checking Power Supply Status on Cisco Catalyst Switches (IOS and IOS-XE)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>With the distinction between chassis power and PoE established, you can run platform-specific CLI commands to inspect PSU slots on Cisco Catalyst switches. On stackable access switches (such as the Catalyst 2960-X, 3850, 9200, and 9300 series), power supply slots are labeled by switch member number and bay letter (<code>1A<\/code> for Switch 1 Slot A, <code>1B<\/code> for Switch 1 Slot B).<\/p>\n<p>Use the following read-only CLI commands in privileged EXEC mode (<code>Switch#<\/code>) to check power supply health across fixed, stacked, and modular Catalyst platforms:<\/p>\n<pre><code class=\"language-ios\">! 1. Check PSU status on a standalone Catalyst switch or active stack views\nSwitch# show env power\nSW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts\n--  ------------------  ----------  ---------------  -------  -------  -----\n1A  PWR-C1-715WAC       LIT221010UE OK               Good     Good     715\n1B  PWR-C1-715WAC       LIT221010UF OK               Good     Good     715\n\n! 2. Check all PSU slots across every member in a Catalyst 9200\/9300 stack\nSwitch# show environment power all\nSW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts\n--  ------------------  ----------  ---------------  -------  -------  -----\n1A  PWR-C1-1100WAC      DCC2401A112 OK               Good     Good     1100\n1B  Not Present\n2A  PWR-C1-1100WAC      DCC2401A119 OK               Good     Good     1100\n2B  PWR-C1-1100WAC      DCC2401A120 No Input Power   Bad      Bad      1100\n\n! 3. Narrow the output to a specific switch member in a stack (e.g., Member 2)\nSwitch# show environment power switch 2\n\n! 4. Verify StackPower pooling and redundancy mode on Catalyst 9300\/3850\nSwitch# show stack-power detail\n\n! 5. Check PSU status, fan tray draw, and live wattage on modular\/core Catalyst 9400\/9500\/9600\nSwitch# show environment status\nSwitch# show power detail\n<\/code><\/pre>\n<p>When reviewing the Catalyst CLI output above:<br \/>\n* <strong>Slot Identifiers (<code>1A<\/code>, <code>1B<\/code>):<\/strong> Confirm that both <code>A<\/code> and <code>B<\/code> slots show <code>OK<\/code> and <code>Good<\/code> if the switch is designed for dual-PSU redundancy. Slot <code>B<\/code> is physically located closest to the outer edge of the chassis on Catalyst 9300 switches.<br \/>\n* <strong>Rated vs. Live Wattage:<\/strong> On Catalyst 9200 and 9300 series switches, the <code>Watts<\/code> column in <code>show env power<\/code> displays the <strong>rated capacity<\/strong> of the power supply, not live power draw. To view live input\/output consumption on supported IOS-XE releases (17.8.1 and later) or Catalyst 9400\/9500\/9600 switches, use <code>show power detail<\/code> or <code>show environment all<\/code>.<\/p>\n<p><strong>Takeaway:<\/strong> Run <code>show environment power all<\/code> on stackable Catalyst switches to audit every member&#8217;s primary and redundant PSU slots in a single view.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Checking_Power_Supply_Status_and_Wattage_on_Cisco_Nexus_Switches_NX-OS\"><\/span>Checking Power Supply Status and Wattage on Cisco Nexus Switches (NX-OS)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Unlike fixed Catalyst switches that primarily display rated PSU capacity in their basic environment tables, data center Cisco Nexus switches (such as the Nexus 9000, 7000, and 3000 series running NX-OS) report both <strong>Actual Output<\/strong>, <strong>Actual Input<\/strong>, and <strong>Total Capacity<\/strong> alongside the configured vs. operational power redundancy modes in a single command.<\/p>\n<p>Use the following NX-OS CLI commands to inspect PSU health, live power consumption, and redundancy states:<\/p>\n<pre><code class=\"language-nxos\">! 1. View PSU status, live input\/output wattage, and redundancy mode on NX-OS\nnexus-9300# show environment power\nPower Supply:\nVoltage: 12 Volts\nPower                             Actual      Actual        Total\nSupply    Model                   Output      Input      Capacity    Status\n                                 (Watts )    (Watts )     (Watts )\n-------  -------------------  ----------  ----------  ----------  --------------\n1        NXA-PAC-650W-PE          92 W       104 W        650 W      Ok\n2        NXA-PAC-650W-PE          94 W       104 W        650 W      Ok\n\nPower Usage Summary:\n--------------------\nPower Supply redundancy mode (configured)                PS-Redundant\nPower Supply redundancy mode (operational)               PS-Redundant\n\nTotal Power Capacity (based on configured mode)             650.00 W\nTotal Power of all Inputs (cumulative)                     1300.00 W\nTotal Power Output (actual draw)                            186.00 W\nTotal Power Input (actual draw)                             208.00 W\nTotal Power Allocated (budget)                                N\/A\nTotal Power Available for additional modules                  N\/A\n\n! 2. View granular PSU sensor details and hardware thresholds\nnexus-9300# show environment power detail\n\n! 3. Configure PSU redundancy mode (if operational mode does not match design)\nnexus-9300# configure terminal\nnexus-9300(config)# power redundancy-mode ps-redundant\nnexus-9300(config)# copy running-config startup-config\n<\/code><\/pre>\n<p>Key fields to verify on Nexus switches include:<br \/>\n* <strong>Configured vs. Operational Redundancy Mode:<\/strong> Ensure both lines match (e.g., <code>PS-Redundant<\/code> for N+1 PSU protection, <code>Insrc-Redundant<\/code> for grid\/input source redundancy, or <code>Combined<\/code> for full non-redundant capacity). If configured is <code>PS-Redundant<\/code> but operational drops to <code>Non-Redundant<\/code>, one PSU has failed or total chassis load has exceeded a single PSU&#8217;s capacity.<br \/>\n* <strong>Actual Input vs. Actual Output:<\/strong> <code>Actual Input<\/code> reflects the AC\/DC power drawn from the rack PDU, while <code>Actual Output<\/code> reflects the 12V DC power delivered to the switch backplane; the difference represents normal PSU conversion inefficiency (typically 10% to 17%).<\/p>\n<p><strong>Takeaway:<\/strong> On Cisco Nexus switches, always verify that the operational redundancy mode matches the configured mode and that live <code>Total Power Output<\/code> remains below the single-PSU capacity threshold (<code>Total Power Capacity based on configured mode<\/code>).<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Troubleshooting_Faulty_Bad_or_No_Input_Power_Supply_States\"><\/span>Troubleshooting Faulty, Bad, or No Input Power Supply States<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When a CLI check reveals a non-normal state\u2014such as <code>No Input Power<\/code>, <code>Bad<\/code>, <code>Disabled<\/code>, or <code>None<\/code>\u2014follow this sequential diagnostic workflow to isolate whether the failure lies in the CLI configuration, upstream rack power, thermal sensors, or the PSU hardware itself.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Check_CLI_Administrative_State_and_Syslog_History\"><\/span>Step 1: Check CLI Administrative State and Syslog History<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>On Catalyst switches, a power supply slot can be administratively disabled in software even when physically plugged in. Check recent environmental syslog events (<code>%PLATFORM_ENV<\/code> on IOS-XE or <code>%PLATFORM-4-PFM_PS<\/code> on NX-OS) and re-enable the slot if it shows <code>Disabled<\/code>:<br \/>\n* Check logs: <code>show logging | include ENV|POWER|FRU|PFM_PS<\/code><br \/>\n* Re-enable an IOS-XE PSU slot: <code>power supply &lt;switch-number&gt; slot {A | B} on<\/code> (e.g., <code>power supply 1 slot B on<\/code>).<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Inspect_PSU_Fan_and_Temperature_Sensors\"><\/span>Step 2: Inspect PSU Fan and Temperature Sensors<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A power supply will automatically shut down to protect the chassis if its internal blower fails or ambient intake temperatures exceed critical thresholds.<br \/>\n* Run <code>show env fan<\/code> and <code>show env temperature<\/code> (or <code>show environment all<\/code> on IOS-XE; <code>show environment fan<\/code> and <code>show environment temperature<\/code> on NX-OS).<br \/>\n* If the status reads <code>Fan Faulty<\/code> or a thermal sensor is in a <code>CRITICAL<\/code>\/<code>SHUTDOWN<\/code> state, clear any airflow obstructions at the rack exhaust\/intake and prepare to replace the PSU.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Verify_Physical_PSU_LED_Indicators\"><\/span>Step 3: Verify Physical PSU LED Indicators<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Before pulling any cables, inspect the physical LEDs on the faceplate of the power supply module:<br \/>\n* <strong>Solid Green (OK \/ AC OK):<\/strong> Input power is within valid voltage range and the PSU is operating normally.<br \/>\n* <strong>Off:<\/strong> No AC\/DC input power is reaching the supply, or the entire switch is unpowered.<br \/>\n* <strong>Blinking Amber \/ Blinking Red:<\/strong> On a dual-PSU switch, this typically indicates that one PSU has lost input power while the second PSU is actively powering the chassis, or the supply is administratively disabled.<br \/>\n* <strong>Solid Amber \/ Solid Red (Fault):<\/strong> The PSU has experienced an internal hardware fault, over-voltage, over-current, or over-temperature shutdown and requires replacement.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_4_Isolate_Upstream_Cords_PDUs_and_Brownout_Lockups\"><\/span>Step 4: Isolate Upstream Cords, PDUs, and Brownout Lockups<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If the CLI reports <code>No Input Power<\/code> (or <code>Shutdown<\/code>\/<code>None<\/code> on NX-OS):<br \/>\n1. Ensure the power cord retention clip is secure and the C13\/C15\/C19 connector is fully seated in the PSU inlet.<br \/>\n2. Swap the power cord to a known-good outlet on the rack PDU to rule out a tripped circuit breaker or dead PDU receptacle.<br \/>\n3. <strong>Reseat the PSU module:<\/strong> On certain Cisco Nexus 9000 (e.g., <code>NXA-PAC-650W<\/code> under CSCwi62100) and Catalyst platforms, a brief upstream voltage brownout can cause a PSU to report as <code>None<\/code> or <code>Bad<\/code> in the CLI even while its physical LED remains green. Unplug the power cable, unlatch and slide the PSU out of the bay for 15 seconds, firmly reseat it until the latch clicks, and reconnect the power cord.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_5_Confirm_Hardware_Detection_for_RMA_show_inventory\"><\/span>Step 5: Confirm Hardware Detection for RMA (<code>show inventory<\/code>)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If reseating the unit and verifying AC\/DC input voltage does not clear a <code>Bad<\/code>, <code>Faulty<\/code>, or unexpected <code>Not Present<\/code> state, run <code>show inventory<\/code>. If the PSU&#8217;s PID and Serial Number fail to populate in <code>show inventory<\/code> while seated in a known-good slot, open a Cisco TAC case for an RMA replacement.<\/p>\n<p><strong>Takeaway:<\/strong> Correlate CLI status messages with physical PSU LEDs and power cord checks before replacing hardware, as <code>No Input Power<\/code> and brownout-induced <code>None<\/code> states are most often resolved by restoring upstream feed or reseating the module.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Monitoring_Cisco_Switch_Power_Supplies_via_SNMP_OIDs_and_Traps\"><\/span>Monitoring Cisco Switch Power Supplies via SNMP OIDs and Traps<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Rather than relying on manual CLI checks, network engineers should poll PSU status continuously and enable automated SNMP traps in monitoring platforms (such as SolarWinds, PRTG, Zabbix, Nagios, or LibreNMS). Cisco switches expose power supply health primarily through <code>CISCO-ENVMON-MIB<\/code> (for fixed\/stackable switches) and <code>CISCO-ENTITY-FRU-CONTROL-MIB<\/code> (for modular Catalyst and Nexus switches).<\/p>\n<p>Use the following SNMP OIDs, <code>snmpwalk<\/code> commands, and switch configuration templates to set up automated alerting:<\/p>\n<pre><code class=\"language-bash\"># 1. Poll CISCO-ENVMON-MIB Power Supply Description &amp; Operational State\n# ciscoEnvMonSupplyStatusDescr: .1.3.6.1.4.1.9.9.13.1.5.1.2\nsnmpwalk -v2c -c &lt;COMMUNITY_STRING&gt; &lt;SWITCH_IP&gt; 1.3.6.1.4.1.9.9.13.1.5.1.2\n\n# ciscoEnvMonSupplyState: .1.3.6.1.4.1.9.9.13.1.5.1.3\n# Returns CiscoEnvMonState Integer:\n# 1 = normal | 2 = warning | 3 = critical | 4 = shutdown | 5 = notPresent | 6 = notFunctioning\nsnmpwalk -v2c -c &lt;COMMUNITY_STRING&gt; &lt;SWITCH_IP&gt; 1.3.6.1.4.1.9.9.13.1.5.1.3\n\n# ciscoEnvMonSupplySource: .1.3.6.1.4.1.9.9.13.1.5.1.4\n# Returns: 1 = unknown | 2 = ac | 3 = dc | 4 = externalPowerSupply | 5 = internalRedundant\nsnmpwalk -v2c -c &lt;COMMUNITY_STRING&gt; &lt;SWITCH_IP&gt; 1.3.6.1.4.1.9.9.13.1.5.1.4\n\n# 2. Poll CISCO-ENTITY-FRU-CONTROL-MIB (Modular Catalyst 9400\/9600 &amp; Nexus NX-OS)\n# cefcFRUPowerOperStatus: .1.3.6.1.4.1.9.9.117.1.1.2.1.2\n# Returns PowerOperType Integer (e.g., 1 = offEnvOther, 2 = on, 3 = offAdmin, 4 = offDenied, 5 = offEnvPower)\nsnmpbulkwalk -v2c -c &lt;COMMUNITY_STRING&gt; &lt;SWITCH_IP&gt; 1.3.6.1.4.1.9.9.117.1.1.2.1.2\n<\/code><\/pre>\n<p>To ensure the switch immediately pushes an alert when a redundant PSU fails or loses input power, apply this configuration template on the switch:<\/p>\n<pre><code class=\"language-ios\">! Enable SNMP environmental and FRU power supply traps on Cisco IOS \/ IOS-XE\nSwitch(config)# snmp-server enable traps envmon supply fan temperature\nSwitch(config)# snmp-server enable traps fru-ctrl\nSwitch(config)# snmp-server host &lt;NMS_SERVER_IP&gt; version 2c &lt;COMMUNITY_STRING&gt; envmon fru-ctrl\n<\/code><\/pre>\n<p><strong>Takeaway:<\/strong> Configure your NMS to poll <code>1.3.6.1.4.1.9.9.13.1.5.1.3<\/code> (<code>ciscoEnvMonSupplyState<\/code>) and trigger a high-priority alert whenever the returned integer deviates from <code>1<\/code> (<code>normal<\/code>).<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Official_Cisco_Command_Reference_and_Hardware_Documentation_Specifications\"><\/span>Official Cisco Command Reference and Hardware Documentation Specifications<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For formal syntax verification, release-specific MIB behavior, and physical chassis specifications, consult the following command reference definitions and official Cisco documentation manuals:<\/p>\n<ul>\n<li><strong>Command Syntax (Cisco IOS \/ IOS-XE):<\/strong><br \/>\n  <code>show environment power [all | switch switch-number]<\/code><\/li>\n<li><strong>Syntax Description:<\/strong>\n<ul>\n<li><code>all<\/code> \u2014 <em>(Optional)<\/em> Displays the internal power supply status for all switches in a StackWise or StackWise Virtual ring.<\/li>\n<li><code>switch switch-number<\/code> \u2014 <em>(Optional)<\/em> Displays the internal power supply status only for the specified stack member. Valid range is <code>1<\/code> to <code>9<\/code> (or <code>1<\/code> to <code>16<\/code> depending on platform architecture).<\/li>\n<\/ul>\n<\/li>\n<li><strong>Command Mode:<\/strong> User EXEC (<code>Switch&gt;<\/code>) or Privileged EXEC (<code>Switch#<\/code>).<\/li>\n<li><strong>Command Syntax (Cisco NX-OS):<\/strong><br \/>\n  <code>show environment power [detail]<\/code><\/li>\n<li><strong>Syntax Description:<\/strong>\n<ul>\n<li><code>detail<\/code> \u2014 <em>(Optional)<\/em> Displays extended hardware telemetry, including cord connectivity, voltage\/current sensor thresholds, and internal PSU temperature.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Command Mode:<\/strong> Any command mode (<code>switch#<\/code>).<\/li>\n<li><strong>Primary Official Documentation References:<\/strong><\/li>\n<li><em>Cisco Catalyst 9300 Series Switches Hardware Installation Guide<\/em> \u2014 Contains physical PSU installation procedures, AC\/DC input voltage requirements, acoustic\/thermal specifications, and front\/rear PSU LED state tables.<\/li>\n<li><em>System Management Configuration Guide, Cisco IOS XE<\/em> (&#8220;Configuring Internal Power Supplies&#8221; module) \u2014 Details CLI administration of internal PSUs (<code>power supply switch-number slot {A | B} {on | off}<\/code>) and <code>show env power<\/code> field definitions.<\/li>\n<li><em>Cisco Nexus 9000 Series NX-OS Fundamentals and Environment Command Reference<\/em> \u2014 Defines NX-API and CLI outputs for <code>show environment power<\/code>, power usage summary calculations, and redundancy mode configurations.<\/li>\n<\/ul>\n<p><strong>Takeaway:<\/strong> Match your switch&#8217;s exact PID and software train against Cisco&#8217;s Hardware Installation Guide and System Management Command Reference to verify model-specific sensor support.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Checking power supply status on a Cisco switch is a straightforward process once you pair the right command with your hardware platform. Use <code>show environment power all<\/code> on stackable Catalyst switches and <code>show environment power<\/code> on Nexus switches to audit physical PSU health, input\/output wattage, and redundancy modes, while keeping <code>show power inline<\/code> dedicated to port-level PoE diagnostics. By combining routine CLI verification with physical LED checks and proactive SNMP polling on <code>ciscoEnvMonSupplyState<\/code>, you can detect single-feed failures early and prevent unexpected network outages.<\/p>\n<div class='sfsi_Sicons' style='width: 100%; display: inline-block; vertical-align: middle; text-align:left'><div style='margin:0px 8px 0px 0px; line-height: 24px'><span>Please follow and like us:<\/span><\/div><div class='sfsi_socialwpr'><div class='sf_fb_share sf_icon' style='text-align:left;vertical-align: middle;'><a href='https:\/\/www.facebook.com\/sharer\/sharer.php?u=https%3A%2F%2Fcciedump.spoto.net%2Fblog%2Fhow-to-check-power-supply-status-on-cisco-switch_24599.html' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Facebook Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/fbshare_bck.png'  \/><\/a><\/div><div class='sf_twiter sf_icon' style='display: inline-block;vertical-align: middle;width: auto;margin-left: 7px;'>\r\n\t\t\t\t\t\t<a target='_blank' href='https:\/\/twitter.com\/intent\/tweet?text=How+to+Check+Power+Supply+Status+on+Cisco+Switch+https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html'style='display:inline-block' >\r\n\t\t\t\t\t\t\t<img data-pin-nopin= true width='auto' class='sfsi_wicon' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/en_US_Tweet.svg' alt='Tweet' title='Tweet' >\r\n\t\t\t\t\t\t<\/a>\r\n\t\t\t\t\t<\/div><div class='sf_pinit sf_icon' style='text-align:left;vertical-align: middle;float:left;line-height: 33px;width:auto;margin: 0 -2px;'><a href='#'  onclick='sfsi_pinterest_modal_images(event,\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\",\"How to Check Power Supply Status on Cisco Switch\")' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Pin Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/share_icons\/Pinterest_Save\/en_US_save.svg'  \/><\/a><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Maintaining uninterrupted network uptime requires verifying that both primary and redundant power supply units (PSUs) are healthy, properly seated, and receiving stable AC or DC input power. Whether you are auditing dual-power redundancy before a maintenance window, calculating rack power draw, or investigating a syslog alarm, Cisco switches provide detailed environmental telemetry through the command-line&#8230; &raquo; <a class=\"read-more-link\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\">read more<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,608],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Check Power Supply Status on Cisco Switch - SPOTO Official Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Check Power Supply Status on Cisco Switch - SPOTO Official Blog\" \/>\n<meta property=\"og:description\" content=\"Maintaining uninterrupted network uptime requires verifying that both primary and redundant power supply units (PSUs) are healthy, properly seated, and receiving stable AC or DC input power. Whether you are auditing dual-power redundancy before a maintenance window, calculating rack power draw, or investigating a syslog alarm, Cisco switches provide detailed environmental telemetry through the command-line... &raquo; read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\" \/>\n<meta property=\"og:site_name\" content=\"SPOTO Official Blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T09:20:24+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"SPOTO \u7f16\u8f91\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\",\"name\":\"SPOTO Club\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"caption\":\"SPOTO Club\"},\"logo\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\"},\"description\":\"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205\",\"sameAs\":[\"https:\/\/cciedump.spoto.net\/\"]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/\",\"name\":\"SPOTO Official Blog\",\"description\":\"Focus on Online IT Training for 20+ Years\",\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#webpage\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\",\"name\":\"How to Check Power Supply Status on Cisco Switch - SPOTO Official Blog\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\"},\"datePublished\":\"2026-11-17T09:20:24+00:00\",\"dateModified\":\"2026-11-17T09:20:24+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cciedump.spoto.net\/blog\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Check Power Supply Status on Cisco Switch\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#article\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#webpage\"},\"author\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\"},\"headline\":\"How to Check Power Supply Status on Cisco Switch\",\"datePublished\":\"2026-11-17T09:20:24+00:00\",\"dateModified\":\"2026-11-17T09:20:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#webpage\"},\"wordCount\":1834,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"articleSection\":[\"CCNA Certification\",\"Cisco Certification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\",\"name\":\"SPOTO \u7f16\u8f91\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"caption\":\"SPOTO \u7f16\u8f91\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Check Power Supply Status on Cisco Switch - SPOTO Official Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html","og_locale":"en_US","og_type":"article","og_title":"How to Check Power Supply Status on Cisco Switch - SPOTO Official Blog","og_description":"Maintaining uninterrupted network uptime requires verifying that both primary and redundant power supply units (PSUs) are healthy, properly seated, and receiving stable AC or DC input power. Whether you are auditing dual-power redundancy before a maintenance window, calculating rack power draw, or investigating a syslog alarm, Cisco switches provide detailed environmental telemetry through the command-line... &raquo; read more","og_url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html","og_site_name":"SPOTO Official Blog","article_published_time":"2026-11-17T09:20:24+00:00","twitter_card":"summary_large_image","twitter_misc":{"Written by":"SPOTO \u7f16\u8f91","Est. reading time":"13 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Person","Organization"],"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638","name":"SPOTO Club","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","caption":"SPOTO Club"},"logo":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo"},"description":"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205","sameAs":["https:\/\/cciedump.spoto.net\/"]},{"@type":"WebSite","@id":"https:\/\/cciedump.spoto.net\/blog\/#website","url":"https:\/\/cciedump.spoto.net\/blog\/","name":"SPOTO Official Blog","description":"Focus on Online IT Training for 20+ Years","publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#webpage","url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html","name":"How to Check Power Supply Status on Cisco Switch - SPOTO Official Blog","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#website"},"datePublished":"2026-11-17T09:20:24+00:00","dateModified":"2026-11-17T09:20:24+00:00","breadcrumb":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cciedump.spoto.net\/blog"},{"@type":"ListItem","position":2,"name":"How to Check Power Supply Status on Cisco Switch"}]},{"@type":"Article","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#article","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#webpage"},"author":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1"},"headline":"How to Check Power Supply Status on Cisco Switch","datePublished":"2026-11-17T09:20:24+00:00","dateModified":"2026-11-17T09:20:24+00:00","mainEntityOfPage":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#webpage"},"wordCount":1834,"commentCount":0,"publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"articleSection":["CCNA Certification","Cisco Certification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-power-supply-status-on-cisco-switch_24599.html#respond"]}]},{"@type":"Person","@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1","name":"SPOTO \u7f16\u8f91","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","caption":"SPOTO \u7f16\u8f91"}}]}},"_links":{"self":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24599"}],"collection":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/comments?post=24599"}],"version-history":[{"count":0,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24599\/revisions"}],"wp:attachment":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/media?parent=24599"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/categories?post=24599"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/tags?post=24599"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}