{"id":24595,"date":"2026-11-17T17:13:49","date_gmt":"2026-11-17T09:13:49","guid":{"rendered":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html"},"modified":"2026-11-17T17:13:49","modified_gmt":"2026-11-17T09:13:49","slug":"how-to-check-poe-port-on-cisco-switch","status":"publish","type":"post","link":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html","title":{"rendered":"How to Check PoE Port on Cisco Switch"},"content":{"rendered":"<p>Verifying whether a Cisco switch port is actively delivering Power over Ethernet (PoE)\u2014and how much wattage remains in the switch&#8217;s overall power budget\u2014is a routine task when deploying or troubleshooting IP phones, wireless access points, and security cameras. Whether you manage enterprise Catalyst switches via the command-line interface (CLI) or monitor Cisco Business and Meraki switches through a web browser, Cisco provides detailed telemetry down to the milliwatt level. Before inspecting individual port metrics, however, it helps to confirm that your switch hardware supports inline power and that its PoE standard matches your connected devices&#8217; requirements.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_17 counter-hierarchy counter-decimal ez-toc-light-blue\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" style=\"display: none;\"><i class=\"ez-toc-glyphicon ez-toc-icon-toggle\"><\/i><\/a><\/span><\/div>\n<nav><ul class=\"ez-toc-list ez-toc-list-level-1\"><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#How_to_Tell_If_a_Cisco_Switch_Supports_PoE\" title=\"How to Tell If a Cisco Switch Supports PoE\">How to Tell If a Cisco Switch Supports PoE<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Cisco_PoE_Standards_Classes_and_Per-Port_Wattage_Limits\" title=\"Cisco PoE Standards, Classes, and Per-Port Wattage Limits\">Cisco PoE Standards, Classes, and Per-Port Wattage Limits<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#How_to_Check_PoE_Port_Status_and_Power_Budget_via_Cisco_CLI\" title=\"How to Check PoE Port Status and Power Budget via Cisco CLI\">How to Check PoE Port Status and Power Budget via Cisco CLI<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Step_1_Check_the_Switch-Wide_PoE_Summary_and_Port_Table\" title=\"Step 1: Check the Switch-Wide PoE Summary and Port Table\">Step 1: Check the Switch-Wide PoE Summary and Port Table<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Step_2_Inspect_Detailed_PoE_Metrics_on_a_Single_Port\" title=\"Step 2: Inspect Detailed PoE Metrics on a Single Port\">Step 2: Inspect Detailed PoE Metrics on a Single Port<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Step_3_Check_Per-Switch_PoE_Budgets_in_a_Stack\" title=\"Step 3: Check Per-Switch PoE Budgets in a Stack\">Step 3: Check Per-Switch PoE Budgets in a Stack<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#How_to_Check_PoE_Port_Status_via_the_Cisco_Web_GUI\" title=\"How to Check PoE Port Status via the Cisco Web GUI\">How to Check PoE Port Status via the Cisco Web GUI<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#1_Cisco_Catalyst_IOS_XE_WebUI_Catalyst_9000_1000_Series\" title=\"1. Cisco Catalyst IOS XE WebUI (Catalyst 9000 &amp; 1000 Series)\">1. Cisco Catalyst IOS XE WebUI (Catalyst 9000 &amp; 1000 Series)<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#2_Cisco_Business_CBS250CBS350_Catalyst_12001300_Web_GUI\" title=\"2. Cisco Business (CBS250\/CBS350) &amp; Catalyst 1200\/1300 Web GUI\">2. Cisco Business (CBS250\/CBS350) &amp; Catalyst 1200\/1300 Web GUI<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#3_Cisco_Meraki_Cloud_Dashboard_MS_Cloud-Managed_Catalyst_Switches\" title=\"3. Cisco Meraki Cloud Dashboard (MS &amp; Cloud-Managed Catalyst Switches)\">3. Cisco Meraki Cloud Dashboard (MS &amp; Cloud-Managed Catalyst Switches)<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Troubleshooting_a_Cisco_PoE_Port_Not_Providing_Power\" title=\"Troubleshooting a Cisco PoE Port Not Providing Power\">Troubleshooting a Cisco PoE Port Not Providing Power<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Step_1_Verify_PoE_Is_Administratively_Enabled_on_the_Port\" title=\"Step 1: Verify PoE Is Administratively Enabled on the Port\">Step 1: Verify PoE Is Administratively Enabled on the Port<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Step_2_Reset_Bounce_PoE_Power_on_a_Hung_Device\" title=\"Step 2: Reset (Bounce) PoE Power on a Hung Device\">Step 2: Reset (Bounce) PoE Power on a Hung Device<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Step_3_Clear_ilpower_Err-Disabled_States_and_Check_Logs\" title=\"Step 3: Clear ilpower Err-Disabled States and Check Logs\">Step 3: Clear ilpower Err-Disabled States and Check Logs<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Step_4_Resolve_power-deny_and_High-Wattage_Negotiation_Failures\" title=\"Step 4: Resolve power-deny and High-Wattage Negotiation Failures\">Step 4: Resolve power-deny and High-Wattage Negotiation Failures<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Cisco_Catalyst_PoE_Command_Reference_and_Official_Documentation\" title=\"Cisco Catalyst PoE Command Reference and Official Documentation\">Cisco Catalyst PoE Command Reference and Official Documentation<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Core_Cisco_IOS_IOS_XE_PoE_Command_Summary\" title=\"Core Cisco IOS \/ IOS XE PoE Command Summary\">Core Cisco IOS \/ IOS XE PoE Command Summary<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Locating_Official_Cisco_Platform_Documentation\" title=\"Locating Official Cisco Platform Documentation\">Locating Official Cisco Platform Documentation<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Tell_If_a_Cisco_Switch_Supports_PoE\"><\/span>How to Tell If a Cisco Switch Supports PoE<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Before running diagnostic commands on an unresponsive port, confirm that the switch chassis and installed power supplies are physically capable of delivering inline power.<\/p>\n<p><strong>How can I tell if my Cisco switch model supports PoE from the part number?<\/strong><br \/>\nCisco encodes PoE capability directly into the switch Stock Keeping Unit (SKU) or Product ID (PID), typically using a letter suffix immediately following the port count:<br \/>\n* <strong>Data-Only (Non-PoE):<\/strong> Suffixes such as <strong><code>T<\/code><\/strong> (Catalyst 9000\/1000 series, e.g., <code>C9300-24T<\/code> or <code>C1000-24T-4G-L<\/code>) or <strong><code>TS<\/code> \/ <code>S<\/code><\/strong> (legacy Catalyst 2960-X\/3850 series, e.g., <code>WS-C2960X-24TS-L<\/code>) indicate data-only ports with no PoE hardware.<br \/>\n* <strong>PoE+ (Up to 30W per port):<\/strong> Suffixes containing <strong><code>P<\/code><\/strong>, <strong><code>LP<\/code><\/strong>, or <strong><code>FP<\/code><\/strong> indicate IEEE 802.3at PoE+ support. Examples include <code>C9300-24P<\/code>, <code>C9200L-48P-4G<\/code>, <code>CBS350-24P-4G<\/code>, and Meraki <code>MS225-48FP<\/code> (<code>LP<\/code> and <code>FP<\/code> denote Lite\/Partial PoE vs. Full PoE budget across all ports).<br \/>\n* <strong>Cisco UPOE (Up to 60W per port):<\/strong> A <strong><code>U<\/code><\/strong> or <strong><code>UP<\/code><\/strong> suffix indicates universal power over Ethernet across all four twisted pairs (e.g., <code>C9300-24U<\/code>, <code>WS-C3850-48U<\/code>, or Meraki <code>MS390-24UX<\/code>).<br \/>\n* <strong>Cisco UPOE+ (Up to 90W per port):<\/strong> An <strong><code>H<\/code><\/strong> suffix on modular and fixed Catalyst 9000 switches (such as <code>C9300-48H<\/code>) denotes IEEE 802.3bt Type 4 high-power capability.<\/p>\n<p><strong>How do I verify PoE capability on the physical switch front panel?<\/strong><br \/>\nInspect the LED cluster near the <strong>Mode<\/strong> button on the left side of the switch faceplate. PoE-capable Catalyst switches feature a dedicated <strong>PoE<\/strong> status indicator alongside <code>STAT<\/code>, <code>DUPLX<\/code>, <code>SPEED<\/code>, and <code>STACK<\/code>. Pressing the Mode button until the PoE LED illuminates changes the behavior of the individual RJ-45 port LEDs:<br \/>\n* <strong>Solid Green:<\/strong> PoE is active and delivering power to a connected Powered Device (PD).<br \/>\n* <strong>Off:<\/strong> No PD is detected, or PoE is administratively disabled on the port.<br \/>\n* <strong>Alternating Green and Amber:<\/strong> PoE is denied because the switch&#8217;s total inline power budget has been exhausted.<br \/>\n* <strong>Blinking Amber:<\/strong> PoE has been shut down on the port due to a fault, short circuit, or overcurrent condition.<\/p>\n<p><strong>How can I check if a switch has PoE hardware via the CLI without checking the physical chassis?<\/strong><br \/>\nRun <code>show version<\/code> or <code>show inventory<\/code> in EXEC mode to retrieve the exact chassis PID and installed power supply modules. Additionally, attempting to run <code>show power inline<\/code> on a data-only switch will either return an <code>% Invalid input detected at '^' marker<\/code> syntax error or display an empty output with <code>0.0<\/code> Available Watts.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Cisco_PoE_Standards_Classes_and_Per-Port_Wattage_Limits\"><\/span>Cisco PoE Standards, Classes, and Per-Port Wattage Limits<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Once you confirm your switch supports PoE, you must ensure the port&#8217;s PoE tier can supply enough power for the connected endpoint. High-draw devices like pan-tilt-zoom (PTZ) cameras or tri-band Wi-Fi 6E\/7 access points will fail to boot if connected to a standard 15.4W PoE port.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Cisco PoE Tier<\/th>\n<th style=\"text-align: left;\">IEEE Standard<\/th>\n<th style=\"text-align: left;\">PoE Class<\/th>\n<th style=\"text-align: left;\">Max Power at Switch Port (PSE)<\/th>\n<th style=\"text-align: left;\">Assured Power at Device (PD)<\/th>\n<th style=\"text-align: left;\">Active Wire Pairs<\/th>\n<th style=\"text-align: left;\">Typical Powered Devices<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco Legacy Inline Power<\/strong><\/td>\n<td style=\"text-align: left;\">Pre-standard (Cisco Proprietary)<\/td>\n<td style=\"text-align: left;\">N\/A<\/td>\n<td style=\"text-align: left;\">7.0 W<\/td>\n<td style=\"text-align: left;\">~6.3 W<\/td>\n<td style=\"text-align: left;\">2 pairs<\/td>\n<td style=\"text-align: left;\">Legacy Cisco 7900 series IP phones, early Aironet APs<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>PoE (Type 1)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3af<\/td>\n<td style=\"text-align: left;\">Class 0 (Default)<\/td>\n<td style=\"text-align: left;\">15.4 W<\/td>\n<td style=\"text-align: left;\">12.95 W<\/td>\n<td style=\"text-align: left;\">2 pairs<\/td>\n<td style=\"text-align: left;\">Standard VoIP phones, fixed indoor IP cameras<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>PoE (Type 1)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3af<\/td>\n<td style=\"text-align: left;\">Class 1<\/td>\n<td style=\"text-align: left;\">4.0 W<\/td>\n<td style=\"text-align: left;\">3.84 W<\/td>\n<td style=\"text-align: left;\">2 pairs<\/td>\n<td style=\"text-align: left;\">Low-power IoT sensors, basic wall phones<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>PoE (Type 1)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3af<\/td>\n<td style=\"text-align: left;\">Class 2<\/td>\n<td style=\"text-align: left;\">7.0 W<\/td>\n<td style=\"text-align: left;\">6.49 W<\/td>\n<td style=\"text-align: left;\">2 pairs<\/td>\n<td style=\"text-align: left;\">Entry-level IP phones, simple badge readers<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>PoE (Type 1)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3af<\/td>\n<td style=\"text-align: left;\">Class 3<\/td>\n<td style=\"text-align: left;\">15.4 W<\/td>\n<td style=\"text-align: left;\">12.95 W<\/td>\n<td style=\"text-align: left;\">2 pairs<\/td>\n<td style=\"text-align: left;\">Dual-band 802.11ac APs, standard VoIP desk phones<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>PoE+ (Type 2)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3at<\/td>\n<td style=\"text-align: left;\">Class 4<\/td>\n<td style=\"text-align: left;\">30.0 W<\/td>\n<td style=\"text-align: left;\">25.5 W<\/td>\n<td style=\"text-align: left;\">2 pairs<\/td>\n<td style=\"text-align: left;\">Video IP phones, Wi-Fi 6 APs, indoor PTZ cameras<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco UPOE (Type 3)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3bt \/ Cisco UPOE<\/td>\n<td style=\"text-align: left;\">Class 5<\/td>\n<td style=\"text-align: left;\">45.0 W<\/td>\n<td style=\"text-align: left;\">40.0 W<\/td>\n<td style=\"text-align: left;\">4 pairs<\/td>\n<td style=\"text-align: left;\">High-density Wi-Fi 6E APs, outdoor cameras with blowers<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco UPOE (Type 3)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3bt \/ Cisco UPOE<\/td>\n<td style=\"text-align: left;\">Class 6<\/td>\n<td style=\"text-align: left;\">60.0 W<\/td>\n<td style=\"text-align: left;\">51.0 W<\/td>\n<td style=\"text-align: left;\">4 pairs<\/td>\n<td style=\"text-align: left;\">Compact PoE-powered switches, VDI thin clients, multi-radio APs<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco UPOE+ (Type 4)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3bt<\/td>\n<td style=\"text-align: left;\">Class 7<\/td>\n<td style=\"text-align: left;\">75.0 W<\/td>\n<td style=\"text-align: left;\">62.0 W<\/td>\n<td style=\"text-align: left;\">4 pairs<\/td>\n<td style=\"text-align: left;\">Enterprise Wi-Fi 7 APs, smart building PoE lighting controllers<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco UPOE+ (Type 4)<\/strong><\/td>\n<td style=\"text-align: left;\">IEEE 802.3bt<\/td>\n<td style=\"text-align: left;\">Class 8<\/td>\n<td style=\"text-align: left;\">90.0 W<\/td>\n<td style=\"text-align: left;\">71.3 W<\/td>\n<td style=\"text-align: left;\">4 pairs<\/td>\n<td style=\"text-align: left;\">Daisy-chained PoE passthrough switches, digital signage displays<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote>\n<p><strong>Key Takeaway:<\/strong> Always account for cable power loss over Cat5e\/Cat6 runs (up to 100 meters). While a Class 4 PoE+ switch port allocates up to 30.0W at the switch (Power Sourcing Equipment, or PSE), only 25.5W is guaranteed to reach the Powered Device (PD).<\/p>\n<\/blockquote>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Check_PoE_Port_Status_and_Power_Budget_via_Cisco_CLI\"><\/span>How to Check PoE Port Status and Power Budget via Cisco CLI<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Knowing the hardware capabilities and wattage tiers sets the stage for live diagnostics. On Cisco Catalyst switches running Cisco IOS or IOS XE, the <code>show power inline<\/code> command family provides real-time visibility into global power budgets and per-interface consumption.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Check_the_Switch-Wide_PoE_Summary_and_Port_Table\"><\/span>Step 1: Check the Switch-Wide PoE Summary and Port Table<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Log in to the switch CLI and run <code>show power inline<\/code> from User EXEC or Privileged EXEC mode to view both the chassis power budget and the status of every PoE-capable port:<\/p>\n<pre><code class=\"language-text\">Switch# show power inline\nAvailable: 715.0(w)  Used: 68.2(w)  Remaining: 646.8(w)\n\nInterface Admin  Oper       Power   Device              Class Max\n                            (Watts)                            \n--------- ------ ---------- ------- ------------------- ----- ----\nGi1\/0\/1   auto   on         15.4    AIR-AP2802I-B-K9    3     30.0\nGi1\/0\/2   auto   on         26.8    C9130AXI-B          4     30.0\nGi1\/0\/3   auto   off        0.0     n\/a                 n\/a   30.0\nGi1\/0\/4   static on         30.0    IP Camera           4     30.0\nGi1\/0\/5   off    off        0.0     n\/a                 n\/a   30.0\nGi1\/0\/6   auto   power-deny 0.0     n\/a                 n\/a   30.0\n<\/code><\/pre>\n<p>Understand each field in the output:<br \/>\n* <strong>Top Summary (<code>Available \/ Used \/ Remaining<\/code>):<\/strong> Shows the total inline wattage supplied by the switch&#8217;s power supplies, the sum of power currently allocated to active ports, and the remaining wattage available for new devices.<br \/>\n* <strong>Admin:<\/strong> The configured PoE mode on the interface:<br \/>\n  * <code>auto<\/code>: Automatically detects a PD and allocates power up to the negotiated class limit.<br \/>\n  * <code>static<\/code>: Pre-allocates the maximum configured wattage to the port from the switch budget, even if no device is plugged in.<br \/>\n  * <code>off<\/code>: Inline power is administratively disabled (<code>power inline never<\/code>).<br \/>\n* <strong>Oper:<\/strong> The real-time operational state of the port:<br \/>\n  * <code>on<\/code>: Power is actively flowing to the connected device.<br \/>\n  * <code>off<\/code>: No PoE device is connected, or PoE is disabled.<br \/>\n  * <code>power-deny<\/code>: A valid PD was detected, but the switch lacks sufficient <code>Remaining<\/code> wattage in its budget (or the device requested more than the port&#8217;s <code>Max<\/code> limit).<br \/>\n  * <code>faulty<\/code> or <code>err-disable<\/code>: The port shut down due to an overcurrent draw or hardware short circuit.<br \/>\n* <strong>Power (Watts):<\/strong> The power currently allocated to or measured on the port. (Depending on your switch platform and CDP\/LLDP state, this shows either the class cutoff allocation or real-time consumption).<br \/>\n* <strong>Device:<\/strong> The hardware model string reported via CDP or LLDP (<code>Ieee PD<\/code> appears if the device does not advertise a Layer 2 discovery name).<br \/>\n* <strong>Class:<\/strong> The IEEE 802.3 PoE class (<code>0<\/code> through <code>8<\/code>) negotiated during physical layer detection (as covered in the comparison table above).<br \/>\n* <strong>Max:<\/strong> The maximum wattage ceiling permitted on the port.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Inspect_Detailed_PoE_Metrics_on_a_Single_Port\"><\/span>Step 2: Inspect Detailed PoE Metrics on a Single Port<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>To diagnose why a specific port is drawing unexpected wattage or failing negotiation, append the interface ID and the <code>detail<\/code> keyword:<\/p>\n<pre><code class=\"language-text\">Switch# show power inline gigabitethernet 1\/0\/2 detail\n Interface: Gi1\/0\/2\n Inline Power Mode: auto\n Operational status: on\n Device Detected: yes\n Device Type: C9130AXI-B\n IEEE Class: 4\n Discovery mechanism used\/configured: Ieee and Cisco\n Police: on\n\n Power Allocated \n Admin Value: 30.0\n Power drawn from the source: 26.8\n Power available to the device: 25.5\n\n Actual consumption\n Measured at the port: 14.2\n Maximum Power drawn by the device since powered on: 24.9\n\n Absent Counter: 0\n Over Current Counter: 0\n Short Current Counter: 0\n Invalid Signature Counter: 0\n Power Denied Counter: 0\n<\/code><\/pre>\n<p>Pay close attention to the difference between <strong>Power drawn from the source<\/strong> (<code>26.8W<\/code>, which is reserved against your switch&#8217;s PoE budget via IEEE Class or CDP\/LLDP negotiation) and <strong>Measured at the port<\/strong> (<code>14.2W<\/code>, the actual electrical load at that exact second). Reviewing the <strong>Maximum Power drawn by the device since powered on<\/strong> and the fault counters (<code>Over Current<\/code>, <code>Short Current<\/code>, <code>Invalid Signature<\/code>) helps pinpoint intermittent cabling or hardware problems.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Check_Per-Switch_PoE_Budgets_in_a_Stack\"><\/span>Step 3: Check Per-Switch PoE Budgets in a Stack<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>In a Cisco StackWise deployment, check the power budget for a specific stack member or inspect how power supplies are pooled using:<\/p>\n<pre><code class=\"language-text\">Switch# show power inline module 2\nSwitch# show env power all\n<\/code><\/pre>\n<p><code>show env power all<\/code> verifies that all installed power supplies are operational (<code>OK<\/code>) and displays how much wattage is reserved for the switch system versus the PoE pool.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Check_PoE_Port_Status_via_the_Cisco_Web_GUI\"><\/span>How to Check PoE Port Status via the Cisco Web GUI<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>If you prefer visual dashboards over the CLI\u2014or if you manage cloud-native or small-business switches\u2014you can check PoE consumption and port states through Cisco&#8217;s graphical interfaces.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"1_Cisco_Catalyst_IOS_XE_WebUI_Catalyst_9000_1000_Series\"><\/span>1. Cisco Catalyst IOS XE WebUI (Catalyst 9000 &amp; 1000 Series)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ol>\n<li>Open a browser and log in to the switch&#8217;s management IP address via <code>https:\/\/&lt;switch-ip&gt;<\/code>.<\/li>\n<li>On the main <strong>Dashboard<\/strong>, locate the <strong>PoE<\/strong> summary widget to view a gauge of Total, Used, and Remaining wattage.<\/li>\n<li>For per-port telemetry, navigate to <strong>Monitoring &gt; System &gt; PoE<\/strong> in the left-hand menu.<\/li>\n<li>Review the interface table, which lists each port&#8217;s <strong>Admin State<\/strong>, <strong>Oper Status<\/strong>, <strong>Allocated Power (W)<\/strong>, <strong>Device Type<\/strong>, and <strong>PoE Class<\/strong>.<\/li>\n<li>To modify a port&#8217;s inline power settings, go to <strong>Configuration &gt; Interface &gt; Ethernet<\/strong>, click the target port, and select the <strong>PoE<\/strong> tab.<\/li>\n<\/ol>\n<h3><span class=\"ez-toc-section\" id=\"2_Cisco_Business_CBS250CBS350_Catalyst_12001300_Web_GUI\"><\/span>2. Cisco Business (CBS250\/CBS350) &amp; Catalyst 1200\/1300 Web GUI<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ol>\n<li>Log in to the switch web administration page. In the top-right corner, change the <strong>Display Mode<\/strong> dropdown from <strong>Basic<\/strong> to <strong>Advanced<\/strong> (if applicable).<\/li>\n<li>In the left navigation pane, go to <strong>Port Management &gt; PoE &gt; Properties<\/strong> (or <strong>Status and Statistics &gt; PoE<\/strong> on newer firmware).<\/li>\n<li>At the top of the page, check the <strong>System Power Status<\/strong> table to see <strong>Nominal Power<\/strong> (total budget), <strong>Consumed Power<\/strong> (real-time draw), and <strong>Allocated Power<\/strong>.<\/li>\n<li>Scroll down to the <strong>Port Power Table<\/strong> to inspect individual interfaces. Here you can view whether PoE is Enabled, the Operational Status (<code>Delivering Power<\/code>, <code>Searching<\/code>, <code>Disabled<\/code>, or <code>Fault<\/code>), the <strong>Power Allocation (mW)<\/strong>, and real-time <strong>Power Consumption (mW)<\/strong>.<\/li>\n<\/ol>\n<h3><span class=\"ez-toc-section\" id=\"3_Cisco_Meraki_Cloud_Dashboard_MS_Cloud-Managed_Catalyst_Switches\"><\/span>3. Cisco Meraki Cloud Dashboard (MS &amp; Cloud-Managed Catalyst Switches)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ol>\n<li>Sign in to <code>dashboard.meraki.com<\/code> and navigate to <strong>Switching &gt; Monitor &gt; Switches<\/strong>.<\/li>\n<li>Click the target switch from your inventory list.<\/li>\n<li>Near the top of the switch status page, check the <strong>Power<\/strong> bar (for example, <code>182W \/ 740W<\/code>) to verify total PoE draw over the past 24 hours.<\/li>\n<li>Click the <strong>Ports<\/strong> tab (or click the port directly on the virtual switch faceplate graphic).<\/li>\n<li>Inside the port detail view, check the <strong>PoE<\/strong> line under the Status section to see if it reports <code>Active<\/code> along with the exact real-time wattage draw (e.g., <code>11.4 W<\/code>). To see all ports at once, return to the multi-port list view, click the <strong>+<\/strong> (column configuration) icon on the right, and enable the <strong>PoE<\/strong> and <strong>Power draw<\/strong> columns.<\/li>\n<\/ol>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Troubleshooting_a_Cisco_PoE_Port_Not_Providing_Power\"><\/span>Troubleshooting a Cisco PoE Port Not Providing Power<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When the CLI or Web GUI reveals that a port is stuck in <code>off<\/code>, <code>power-deny<\/code>, or <code>err-disabled<\/code> despite a connected device, follow this sequential workflow to restore power.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Verify_PoE_Is_Administratively_Enabled_on_the_Port\"><\/span>Step 1: Verify PoE Is Administratively Enabled on the Port<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If <code>show power inline<\/code> lists <code>Admin<\/code> as <code>off<\/code>, someone previously disabled inline power on that port. Re-enable automatic PoE detection:<\/p>\n<pre><code class=\"language-text\">Switch# configure terminal\nSwitch(config)# interface gigabitethernet 1\/0\/5\nSwitch(config-if)# power inline auto\nSwitch(config-if)# end\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Reset_Bounce_PoE_Power_on_a_Hung_Device\"><\/span>Step 2: Reset (Bounce) PoE Power on a Hung Device<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If an IP camera or wireless access point is frozen (<code>Oper<\/code> shows <code>on<\/code>, but the device is unresponsive on the network), you can remotely power-cycle the physical port without unplugging the patch cable:<\/p>\n<pre><code class=\"language-text\">Switch# configure terminal\nSwitch(config)# interface gigabitethernet 1\/0\/1\nSwitch(config-if)# power inline never\n! Wait 5 to 10 seconds for the device's internal capacitors to fully discharge\nSwitch(config-if)# power inline auto\nSwitch(config-if)# end\n<\/code><\/pre>\n<p><em>(Note: On newer IOS XE releases, you can also run <code>hw-module beacon slot &lt;number&gt; port &lt;number&gt;<\/code> to identify the port or bounce the interface directly with <code>shutdown<\/code> \/ <code>no shutdown<\/code>, though toggling <code>power inline<\/code> specifically forces the PoE controller to drop and renegotiate voltage).<\/em><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Clear_ilpower_Err-Disabled_States_and_Check_Logs\"><\/span>Step 3: Clear <code>ilpower<\/code> Err-Disabled States and Check Logs<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>When a connected device draws more power than its negotiated cutoff limit\u2014or if a damaged Ethernet cable causes a pin short\u2014the switch&#8217;s PoE policing engine shuts down the port and places it into an <code>ilpower<\/code> error-disabled state.<br \/>\n1. Check for error-disabled ports and inspect the system log:<br \/>\n   <code>text<br \/>\n   Switch# show interfaces status err-disabled<br \/>\n   Switch# show logging | include ILPOWER<\/code><br \/>\n   Look for messages such as <code>%ILPOWER-3-CONTROLLER_PORT_ERR<\/code> (often caused by bad cabling or a faulty PD) or <code>%ILPOWER-5-ILPOWER_POWER_DENY<\/code>.<br \/>\n2. After replacing a suspect patch cord or verifying the device&#8217;s wattage requirements, reset the port out of <code>err-disabled<\/code> by cycling the interface:<br \/>\n   <code>text<br \/>\n   Switch# configure terminal<br \/>\n   Switch(config)# interface gigabitethernet 1\/0\/6<br \/>\n   Switch(config-if)# shutdown<br \/>\n   Switch(config-if)# no shutdown<br \/>\n   Switch(config-if)# end<\/code><br \/>\n3. Optionally, configure the switch to automatically recover from PoE faults after a timeout interval:<br \/>\n   <code>text<br \/>\n   Switch(config)# errdisable recovery cause ilpower<br \/>\n   Switch(config)# errdisable recovery interval 300<\/code><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_4_Resolve_power-deny_and_High-Wattage_Negotiation_Failures\"><\/span>Step 4: Resolve <code>power-deny<\/code> and High-Wattage Negotiation Failures<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If a port displays <code>power-deny<\/code> or a Wi-Fi 6\/7 access point boots in low-power degraded mode (disabling its 5 GHz or 6 GHz radios), check three common configuration limits:<br \/>\n* <strong>Port Max Wattage Cap:<\/strong> Check if a manual cap was configured on the interface (<code>power inline auto max &lt;milliwatts&gt;<\/code>). Remove any restrictive cap by running <code>default power inline<\/code> under the interface configuration.<br \/>\n* <strong>Layer 2 Power Negotiation (CDP\/LLDP):<\/strong> Many Class 4 (30W) and Class 6\/8 (60W\u201390W) devices initially classify at a lower IEEE physical tier and rely on CDP or LLDP to request their full operational power. Ensure both protocols are active on the port:<br \/>\n  <code>text<br \/>\n  Switch(config-if)# cdp enable<br \/>\n  Switch(config-if)# lldp transmit<br \/>\n  Switch(config-if)# lldp receive<\/code><br \/>\n* <strong>Four-Pair \/ UPOE Activation:<\/strong> On UPOE-capable switches powering 60W+ devices, verify that four-pair power delivery is enabled on the interface (<code>power inline four-pair forced<\/code> on older IOS XE releases, or verify IEEE 802.3bt negotiation on newer releases) and ensure the switch&#8217;s global power budget has enough <code>Remaining<\/code> watts. For mission-critical endpoints on a heavily loaded switch, assign high PoE priority (<code>power inline port priority high<\/code>) so those ports retain power if a power supply fails.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Cisco_Catalyst_PoE_Command_Reference_and_Official_Documentation\"><\/span>Cisco Catalyst PoE Command Reference and Official Documentation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For platform-specific syntax nuances, MIB definitions, and hardware release notes, consult the command reference summary and official Cisco documentation hierarchy below.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Core_Cisco_IOS_IOS_XE_PoE_Command_Summary\"><\/span>Core Cisco IOS \/ IOS XE PoE Command Summary<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Command Syntax<\/th>\n<th style=\"text-align: left;\">Command Mode<\/th>\n<th style=\"text-align: left;\">Function and Usage<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><code>show power inline [interface-id] [detail]<\/code><\/td>\n<td style=\"text-align: left;\">User EXEC (<code>&gt;<\/code>) or Privileged EXEC (<code>#<\/code>)<\/td>\n<td style=\"text-align: left;\">Displays global inline power budget (<code>Available<\/code>, <code>Used<\/code>, <code>Remaining<\/code>) and per-port PoE operational states, classes, and measured wattage.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><code>show power inline police [interface-id]<\/code><\/td>\n<td style=\"text-align: left;\">Privileged EXEC (<code>#<\/code>)<\/td>\n<td style=\"text-align: left;\">Displays real-time power policing thresholds, cutoff values, and overcurrent action configurations (<code>errdisable<\/code> vs. <code>log<\/code>).<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><code>show power inline priority [interface-id]<\/code><\/td>\n<td style=\"text-align: left;\">Privileged EXEC (<code>#<\/code>)<\/td>\n<td style=\"text-align: left;\">Displays port power priority assignments (<code>low<\/code>, <code>high<\/code>, <code>critical<\/code>) used during power supply budget brownouts.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><code>power inline {auto [max max-wattage] \\| never \\| static [max max-wattage]}<\/code><\/td>\n<td style=\"text-align: left;\">Interface Configuration (<code>config-if#<\/code>)<\/td>\n<td style=\"text-align: left;\">Sets the administrative PoE mode on an interface. <code>max-wattage<\/code> is specified in milliwatts (e.g., <code>4000<\/code> to <code>30000<\/code> for PoE+, up to <code>60000<\/code> or <code>90000<\/code> on UPOE\/UPOE+ ports).<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><code>power inline consumption default milli-watts<\/code><\/td>\n<td style=\"text-align: left;\">Global (<code>config#<\/code>) or Interface (<code>config-if#<\/code>)<\/td>\n<td style=\"text-align: left;\">Overrides class-based power reservation and allocates a fixed milliwatt value from the switch budget (use with caution to avoid oversubscribing the PSU).<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><code>power inline police [action {errdisable \\| log}]<\/code><\/td>\n<td style=\"text-align: left;\">Interface Configuration (<code>config-if#<\/code>)<\/td>\n<td style=\"text-align: left;\">Enables real-time hardware monitoring of actual port power draw against the cutoff threshold and defines the violation action.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><code>power inline port priority {high \\| low}<\/code><\/td>\n<td style=\"text-align: left;\">Interface Configuration (<code>config-if#<\/code>)<\/td>\n<td style=\"text-align: left;\">Prioritizes specific interfaces so they continue receiving power if a redundant PSU fails and total chassis capacity drops below demand.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span class=\"ez-toc-section\" id=\"Locating_Official_Cisco_Platform_Documentation\"><\/span>Locating Official Cisco Platform Documentation<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cisco structures its PoE configuration manuals by switch family and IOS XE release train on <code>cisco.com<\/code>:<br \/>\n* <strong>Catalyst 9000 Series (9200, 9300, 9400):<\/strong> Navigate to <em>Cisco Support &gt; Switches &gt; Catalyst 9300 Series Switches &gt; Configuration Guides<\/em>, select your installed <strong>Cisco IOS XE Release<\/strong> (e.g., IOS XE Dublin 17.12.x or IOS XE 17.15.x), and open the <strong>Interface and Hardware Components Configuration Guide &gt; Configuring Power over Ethernet<\/strong>. This document covers Fast PoE, Perpetual PoE (which maintains inline power across switch warm reloads), and IEEE 802.3bt Type 4 UPOE+ behavior.<br \/>\n* <strong>Catalyst 1000 and Classic IOS (2960-X\/XR):<\/strong> Refer to the <em>Interface and Hardware Components Configuration Guide<\/em> for Cisco IOS Release 15.2(7)E, specifically the chapter titled <strong>Configuring PoE<\/strong> and the <strong>EnergyWise \/ PoE Command Reference<\/strong>.<br \/>\n* <strong>Cisco Business (CBS250\/350) and Catalyst 1200\/1300:<\/strong> Consult the <em>Administration Guide<\/em> and <em>CLI Guide<\/em> for your specific model series under <em>Small Business Support<\/em>, which details the simplified OS syntax (<code>show power inline<\/code> and <code>power inline {auto | never | limit}<\/code>).<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Checking a PoE port on a Cisco switch begins with confirming your hardware SKU and PoE class limits, followed by running <code>show power inline<\/code> and <code>show power inline &lt;interface&gt; detail<\/code> (or inspecting the PoE dashboard in the WebUI) to compare allocated versus actual wattage draw. By combining real-time port telemetry with targeted troubleshooting\u2014such as enabling CDP\/LLDP negotiation, clearing <code>ilpower<\/code> error-disabled states, and monitoring your chassis power budget\u2014you can quickly isolate cabling faults and keep all powered endpoints running reliably.<\/p>\n<div class='sfsi_Sicons' style='width: 100%; display: inline-block; vertical-align: middle; text-align:left'><div style='margin:0px 8px 0px 0px; line-height: 24px'><span>Please follow and like us:<\/span><\/div><div class='sfsi_socialwpr'><div class='sf_fb_share sf_icon' style='text-align:left;vertical-align: middle;'><a href='https:\/\/www.facebook.com\/sharer\/sharer.php?u=https%3A%2F%2Fcciedump.spoto.net%2Fblog%2Fhow-to-check-poe-port-on-cisco-switch_24595.html' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Facebook Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/fbshare_bck.png'  \/><\/a><\/div><div class='sf_twiter sf_icon' style='display: inline-block;vertical-align: middle;width: auto;margin-left: 7px;'>\r\n\t\t\t\t\t\t<a target='_blank' href='https:\/\/twitter.com\/intent\/tweet?text=How+to+Check+PoE+Port+on+Cisco+Switch+https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html'style='display:inline-block' >\r\n\t\t\t\t\t\t\t<img data-pin-nopin= true width='auto' class='sfsi_wicon' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/en_US_Tweet.svg' alt='Tweet' title='Tweet' >\r\n\t\t\t\t\t\t<\/a>\r\n\t\t\t\t\t<\/div><div class='sf_pinit sf_icon' style='text-align:left;vertical-align: middle;float:left;line-height: 33px;width:auto;margin: 0 -2px;'><a href='#'  onclick='sfsi_pinterest_modal_images(event,\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\",\"How to Check PoE Port on Cisco Switch\")' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Pin Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/share_icons\/Pinterest_Save\/en_US_save.svg'  \/><\/a><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Verifying whether a Cisco switch port is actively delivering Power over Ethernet (PoE)\u2014and how much wattage remains in the switch&#8217;s overall power budget\u2014is a routine task when deploying or troubleshooting IP phones, wireless access points, and security cameras. Whether you manage enterprise Catalyst switches via the command-line interface (CLI) or monitor Cisco Business and Meraki&#8230; &raquo; <a class=\"read-more-link\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\">read more<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,608],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Check PoE Port on Cisco Switch - SPOTO Official Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Check PoE Port on Cisco Switch - SPOTO Official Blog\" \/>\n<meta property=\"og:description\" content=\"Verifying whether a Cisco switch port is actively delivering Power over Ethernet (PoE)\u2014and how much wattage remains in the switch&#8217;s overall power budget\u2014is a routine task when deploying or troubleshooting IP phones, wireless access points, and security cameras. Whether you manage enterprise Catalyst switches via the command-line interface (CLI) or monitor Cisco Business and Meraki... &raquo; read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\" \/>\n<meta property=\"og:site_name\" content=\"SPOTO Official Blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T09:13:49+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"SPOTO \u7f16\u8f91\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\",\"name\":\"SPOTO Club\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"caption\":\"SPOTO Club\"},\"logo\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\"},\"description\":\"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205\",\"sameAs\":[\"https:\/\/cciedump.spoto.net\/\"]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/\",\"name\":\"SPOTO Official Blog\",\"description\":\"Focus on Online IT Training for 20+ Years\",\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#webpage\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\",\"name\":\"How to Check PoE Port on Cisco Switch - SPOTO Official Blog\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\"},\"datePublished\":\"2026-11-17T09:13:49+00:00\",\"dateModified\":\"2026-11-17T09:13:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cciedump.spoto.net\/blog\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Check PoE Port on Cisco Switch\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#article\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#webpage\"},\"author\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\"},\"headline\":\"How to Check PoE Port on Cisco Switch\",\"datePublished\":\"2026-11-17T09:13:49+00:00\",\"dateModified\":\"2026-11-17T09:13:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#webpage\"},\"wordCount\":2361,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"articleSection\":[\"CCNA Certification\",\"Cisco Certification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\",\"name\":\"SPOTO \u7f16\u8f91\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"caption\":\"SPOTO \u7f16\u8f91\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Check PoE Port on Cisco Switch - SPOTO Official Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html","og_locale":"en_US","og_type":"article","og_title":"How to Check PoE Port on Cisco Switch - SPOTO Official Blog","og_description":"Verifying whether a Cisco switch port is actively delivering Power over Ethernet (PoE)\u2014and how much wattage remains in the switch&#8217;s overall power budget\u2014is a routine task when deploying or troubleshooting IP phones, wireless access points, and security cameras. Whether you manage enterprise Catalyst switches via the command-line interface (CLI) or monitor Cisco Business and Meraki... &raquo; read more","og_url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html","og_site_name":"SPOTO Official Blog","article_published_time":"2026-11-17T09:13:49+00:00","twitter_card":"summary_large_image","twitter_misc":{"Written by":"SPOTO \u7f16\u8f91","Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Person","Organization"],"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638","name":"SPOTO Club","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","caption":"SPOTO Club"},"logo":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo"},"description":"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205","sameAs":["https:\/\/cciedump.spoto.net\/"]},{"@type":"WebSite","@id":"https:\/\/cciedump.spoto.net\/blog\/#website","url":"https:\/\/cciedump.spoto.net\/blog\/","name":"SPOTO Official Blog","description":"Focus on Online IT Training for 20+ Years","publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#webpage","url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html","name":"How to Check PoE Port on Cisco Switch - SPOTO Official Blog","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#website"},"datePublished":"2026-11-17T09:13:49+00:00","dateModified":"2026-11-17T09:13:49+00:00","breadcrumb":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cciedump.spoto.net\/blog"},{"@type":"ListItem","position":2,"name":"How to Check PoE Port on Cisco Switch"}]},{"@type":"Article","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#article","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#webpage"},"author":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1"},"headline":"How to Check PoE Port on Cisco Switch","datePublished":"2026-11-17T09:13:49+00:00","dateModified":"2026-11-17T09:13:49+00:00","mainEntityOfPage":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#webpage"},"wordCount":2361,"commentCount":0,"publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"articleSection":["CCNA Certification","Cisco Certification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-port-on-cisco-switch_24595.html#respond"]}]},{"@type":"Person","@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1","name":"SPOTO \u7f16\u8f91","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","caption":"SPOTO \u7f16\u8f91"}}]}},"_links":{"self":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24595"}],"collection":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/comments?post=24595"}],"version-history":[{"count":0,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24595\/revisions"}],"wp:attachment":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/media?parent=24595"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/categories?post=24595"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/tags?post=24595"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}