{"id":24592,"date":"2026-11-17T17:02:06","date_gmt":"2026-11-17T09:02:06","guid":{"rendered":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html"},"modified":"2026-11-17T17:02:06","modified_gmt":"2026-11-17T09:02:06","slug":"how-to-check-poe-on-cisco-switch","status":"publish","type":"post","link":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html","title":{"rendered":"How to Check PoE on Cisco Switch"},"content":{"rendered":"<p>Managing wireless access points, IP phones, and security cameras requires clear visibility into how much electrical power your network switches are supplying. Whether you are planning new device deployments or diagnosing why a connected device refuses to boot, knowing how to check Power over Ethernet (PoE) on a Cisco switch allows you to track per-port wattage, verify remaining power budgets, and isolate hardware faults before you overload a power supply.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_17 counter-hierarchy counter-decimal ez-toc-light-blue\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" style=\"display: none;\"><i class=\"ez-toc-glyphicon ez-toc-icon-toggle\"><\/i><\/a><\/span><\/div>\n<nav><ul class=\"ez-toc-list ez-toc-list-level-1\"><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#How_to_Tell_If_a_Cisco_Switch_Supports_PoE_PoE_or_UPOE\" title=\"How to Tell If a Cisco Switch Supports PoE, PoE+, or UPOE\">How to Tell If a Cisco Switch Supports PoE, PoE+, or UPOE<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Checking_Cisco_Switch_PoE_Status_and_Power_Budget_via_CLI\" title=\"Checking Cisco Switch PoE Status and Power Budget via CLI\">Checking Cisco Switch PoE Status and Power Budget via CLI<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Checking_PoE_Status_via_Web_GUI_and_Cisco_Meraki_Dashboard\" title=\"Checking PoE Status via Web GUI and Cisco Meraki Dashboard\">Checking PoE Status via Web GUI and Cisco Meraki Dashboard<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#1_Cisco_Catalyst_IOS_XE_Web_UI_Catalyst_9000_Series\" title=\"1. Cisco Catalyst IOS XE Web UI (Catalyst 9000 Series)\">1. Cisco Catalyst IOS XE Web UI (Catalyst 9000 Series)<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#2_Cisco_Business_CBS_250350_and_Catalyst_12001300_Web_GUI\" title=\"2. Cisco Business (CBS 250\/350) and Catalyst 1200\/1300 Web GUI\">2. Cisco Business (CBS 250\/350) and Catalyst 1200\/1300 Web GUI<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#3_Cisco_Meraki_Dashboard_MS_and_Cloud-Managed_Catalyst_Switches\" title=\"3. Cisco Meraki Dashboard (MS and Cloud-Managed Catalyst Switches)\">3. Cisco Meraki Dashboard (MS and Cloud-Managed Catalyst Switches)<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#How_to_Troubleshoot_and_Reset_PoE_on_a_Cisco_Switch_Port\" title=\"How to Troubleshoot and Reset PoE on a Cisco Switch Port\">How to Troubleshoot and Reset PoE on a Cisco Switch Port<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Step_1_Power_Cycle_Reset_PoE_on_a_Single_Port\" title=\"Step 1: Power Cycle (Reset) PoE on a Single Port\">Step 1: Power Cycle (Reset) PoE on a Single Port<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Step_2_Clear_a_PoE_err-disabled_inline-power_Port_State\" title=\"Step 2: Clear a PoE err-disabled (inline-power) Port State\">Step 2: Clear a PoE err-disabled (inline-power) Port State<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Step_3_Resolve_PoE_and_UPOE_Negotiation_Issues\" title=\"Step 3: Resolve PoE+ and UPOE Negotiation Issues\">Step 3: Resolve PoE+ and UPOE Negotiation Issues<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Cisco_IOS_and_IOS_XE_PoE_Command_Reference_and_Platform_Defaults\" title=\"Cisco IOS and IOS XE PoE Command Reference and Platform Defaults\">Cisco IOS and IOS XE PoE Command Reference and Platform Defaults<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Default_PoE_System_Parameters\" title=\"Default PoE System Parameters\">Default PoE System Parameters<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Interface_PoE_Configuration_Command_Syntax\" title=\"Interface PoE Configuration Command Syntax\">Interface PoE Configuration Command Syntax<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Official_Cisco_Documentation_Paths\" title=\"Official Cisco Documentation Paths\">Official Cisco Documentation Paths<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Best_Network_Monitoring_Tools_for_Tracking_Cisco_PoE_Usage_via_SNMP\" title=\"Best Network Monitoring Tools for Tracking Cisco PoE Usage via SNMP\">Best Network Monitoring Tools for Tracking Cisco PoE Usage via SNMP<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Tell_If_a_Cisco_Switch_Supports_PoE_PoE_or_UPOE\"><\/span>How to Tell If a Cisco Switch Supports PoE, PoE+, or UPOE<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Before checking port-level power telemetry, confirm whether your switch hardware physically supports inline power and which IEEE standard it delivers. You can identify a switch&#8217;s PoE capabilities directly from its chassis part number (found on the physical front bezel or in the <code>Model Number<\/code> field of the <code>show version<\/code> command output).<\/p>\n<p>Cisco uses standardized letter codes in the middle suffix of Catalyst and Cisco Business (CBS) model numbers to indicate PoE support, maximum per-port wattage, and chassis power budget allocation:<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Model Suffix Code<\/th>\n<th style=\"text-align: left;\">PoE Tier &amp; IEEE Standard<\/th>\n<th style=\"text-align: left;\">Max Power Per Port<\/th>\n<th style=\"text-align: left;\">Switch Budget Behavior<\/th>\n<th style=\"text-align: left;\">Example Cisco Switch Models<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>T<\/strong>, <strong>L<\/strong>, or <strong>D<\/strong><\/td>\n<td style=\"text-align: left;\">Non-PoE (Data Only)<\/td>\n<td style=\"text-align: left;\">0 W<\/td>\n<td style=\"text-align: left;\">No inline power hardware installed; supports data links only.<\/td>\n<td style=\"text-align: left;\"><code>C9200L-24T-4G<\/code>, <code>WS-C2960X-24TD-L<\/code>, <code>CBS350-24T-4G<\/code><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>LP<\/strong><\/td>\n<td style=\"text-align: left;\">PoE \/ PoE+ (802.3af \/ 802.3at)<\/td>\n<td style=\"text-align: left;\">15.4 W \/ 30 W<\/td>\n<td style=\"text-align: left;\"><strong>Low\/Partial PoE:<\/strong> Lower total switch power budget (~370 W) meant for mixed data and PoE environments.<\/td>\n<td style=\"text-align: left;\"><code>WS-C2960X-48LPS-L<\/code>, <code>WS-C3560X-48PF-L<\/code><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>P<\/strong><\/td>\n<td style=\"text-align: left;\">PoE+ (802.3at)<\/td>\n<td style=\"text-align: left;\">30 W<\/td>\n<td style=\"text-align: left;\"><strong>Standard PoE+:<\/strong> Supports up to 30 W per port, scaled to the capacity of the installed power supply units (PSUs).<\/td>\n<td style=\"text-align: left;\"><code>C9200L-24P-4G<\/code>, <code>C9300-24P<\/code>, <code>CBS350-24P-4G<\/code><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>FP<\/strong><\/td>\n<td style=\"text-align: left;\">PoE+ (802.3at)<\/td>\n<td style=\"text-align: left;\">30 W<\/td>\n<td style=\"text-align: left;\"><strong>Full PoE+:<\/strong> High switch power budget (~740 W+) allowing all 24 or 48 ports to draw full 15.4 W\u201330 W simultaneously.<\/td>\n<td style=\"text-align: left;\"><code>WS-C2960X-48FPS-L<\/code>, <code>CBS350-48FP-4G<\/code><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>U<\/strong> or <strong>UP<\/strong><\/td>\n<td style=\"text-align: left;\">Cisco UPOE (802.3bt Type 3)<\/td>\n<td style=\"text-align: left;\">60 W<\/td>\n<td style=\"text-align: left;\"><strong>Universal PoE:<\/strong> Uses all four twisted pairs to supply high-draw devices such as pan-tilt-zoom cameras and Wi-Fi 6E\/7 APs.<\/td>\n<td style=\"text-align: left;\"><code>C9300-48U<\/code>, <code>WS-C3850-48U<\/code><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>H<\/strong> or <strong>UXM<\/strong><\/td>\n<td style=\"text-align: left;\">Cisco UPOE+ (802.3bt Type 4)<\/td>\n<td style=\"text-align: left;\">90 W<\/td>\n<td style=\"text-align: left;\"><strong>High-Density UPOE+:<\/strong> Delivers up to 90 W per port for daisy-chained PoE switches, building automation lighting, and VDI endpoints.<\/td>\n<td style=\"text-align: left;\"><code>C9300-48H<\/code>, <code>C9300X-48HX<\/code><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Key Takeaway:<\/strong> Always inspect the middle letters of the Cisco model SKU (<code>P<\/code>, <code>FP<\/code>, <code>U<\/code>, or <code>H<\/code>) to verify that your chassis supports the wattage tier required by your connected endpoints.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Checking_Cisco_Switch_PoE_Status_and_Power_Budget_via_CLI\"><\/span>Checking Cisco Switch PoE Status and Power Budget via CLI<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Once you confirm your hardware is PoE-capable, the fastest way to inspect real-time power allocation on Cisco IOS and IOS XE switches is through the command-line interface (CLI) using the <code>show power inline<\/code> command family.<\/p>\n<pre><code class=\"language-ios\">! 1. View total switch power budget and per-port PoE summary\nSwitch# show power inline\n\nModule   Available     Used     Remaining\n          (Watts)     (Watts)    (Watts)\n------   ---------   --------   ---------\n1           740.0      142.4       597.6\n\nInterface Admin  Oper       Power   Device              Class Max\n                            (Watts)\n--------- ------ ---------- ------- ------------------- ----- ----\nGi1\/0\/1   auto   on         15.4    IP Phone 8845       3     30.0\nGi1\/0\/2   auto   on         28.2    AIR-AP3802I-B-K9    4     30.0\nGi1\/0\/3   auto   off        0.0     n\/a                 n\/a   30.0\nGi1\/0\/4   auto   err-disable 0.0    n\/a                 n\/a   30.0\n\n! 2. Filter output to list only ports actively drawing PoE power\nSwitch# show power inline | include on\n\n! 3. Inspect granular PoE telemetry and actual milliwatt draw on a single port\nSwitch# show power inline GigabitEthernet1\/0\/2 detail\n\n Interface: Gi1\/0\/2\n Inline Power Mode: auto\n Operational status: on\n Device Detected: yes\n Device Type: Cisco AIR-AP3802I-B-K9\n IEEE Class: 4\n Discovery mechanism used\/configured: Ieee and Cisco\n Police: off\n Power Allocations\n  Admin Value: 30.0\n  Power drawn from the source: 28.2\n  Power available to the device: 25.5\n  Actual consumption\n   Measured at the port: 14.8\n   Maximum Power drawn by the device since powered on: 24.1\n\n! 4. Verify PSU status and stack-wide power sharing (Catalyst 3850 \/ 9200 \/ 9300)\nSwitch# show env power\nSwitch# show stack-power\n<\/code><\/pre>\n<p>Use these key field definitions to interpret the CLI output:<br \/>\n* <strong>Available \/ Used \/ Remaining (Watts):<\/strong> Displays the switch module&#8217;s total PoE budget, total power currently allocated across all ports, and remaining reserve capacity.<br \/>\n* <strong>Admin:<\/strong> Indicates configured port behavior (<code>auto<\/code> negotiates dynamically, <code>static<\/code> pre-reserves maximum wattage from the budget regardless of link state, <code>off<\/code> disables PoE).<br \/>\n* <strong>Oper:<\/strong> Shows current hardware state (<code>on<\/code> = delivering power, <code>off<\/code> = no powered device detected, <code>err-disable<\/code> or <code>faulty<\/code> = shut down due to overcurrent or short circuit).<br \/>\n* <strong>Actual consumption (Measured at the port):<\/strong> Available in the <code>detail<\/code> view; contrasts the real-time wattage draw (e.g., <code>14.8 W<\/code>) against the negotiated ceiling reserved from the budget (<code>28.2 W<\/code>).<\/p>\n<p><strong>Key Takeaway:<\/strong> Use <code>show power inline<\/code> for a quick budget overview, and append <code>&lt;interface&gt; detail<\/code> whenever you need to distinguish between allocated IEEE class budget and actual real-time wattage draw.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Checking_PoE_Status_via_Web_GUI_and_Cisco_Meraki_Dashboard\"><\/span>Checking PoE Status via Web GUI and Cisco Meraki Dashboard<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>If you manage switches without CLI access or administer cloud-managed networks, you can inspect PoE budgets and port consumption through Cisco&#8217;s graphical interfaces.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"1_Cisco_Catalyst_IOS_XE_Web_UI_Catalyst_9000_Series\"><\/span>1. Cisco Catalyst IOS XE Web UI (Catalyst 9000 Series)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ol>\n<li>Open a web browser, enter the management IP address of the Catalyst switch, and log in with your privileged credentials.<\/li>\n<li>In the left navigation menu, expand <strong>Monitoring &gt; System &gt; PoE<\/strong>.<\/li>\n<li>Review the <strong>Module Summary<\/strong> bar at the top of the page to see total <strong>Available Power<\/strong>, <strong>Used Power<\/strong>, and <strong>Remaining Power<\/strong> in Watts.<\/li>\n<li>Scroll to the <strong>Interface PoE Status<\/strong> table to inspect the operational status, detected IEEE class, and current wattage draw for each port.<\/li>\n<\/ol>\n<h3><span class=\"ez-toc-section\" id=\"2_Cisco_Business_CBS_250350_and_Catalyst_12001300_Web_GUI\"><\/span>2. Cisco Business (CBS 250\/350) and Catalyst 1200\/1300 Web GUI<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ol>\n<li>Sign in to the switch&#8217;s web administration page. If using a CBS series switch, set the top-right <strong>Display Mode<\/strong> toggle to <strong>Advanced<\/strong>.<\/li>\n<li>Navigate to <strong>Port Management &gt; PoE &gt; Properties<\/strong> in the left sidebar.<\/li>\n<li>Check the <strong>Power Status<\/strong> panel to view the <strong>Nominal Power<\/strong> (total budget), <strong>Consumed Power<\/strong> (in Watts and percentage), and configured <strong>Trap Threshold<\/strong>.<\/li>\n<li>Navigate to <strong>Port Management &gt; PoE &gt; Settings<\/strong> to view a port-by-port breakdown showing <strong>PoE Administrative Status<\/strong>, <strong>Operational Status<\/strong>, <strong>Power Allocation (mW)<\/strong>, and <strong>Class<\/strong>.<\/li>\n<\/ol>\n<h3><span class=\"ez-toc-section\" id=\"3_Cisco_Meraki_Dashboard_MS_and_Cloud-Managed_Catalyst_Switches\"><\/span>3. Cisco Meraki Dashboard (MS and Cloud-Managed Catalyst Switches)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ol>\n<li>Log in to the Meraki Dashboard (<code>dashboard.meraki.com<\/code>) and select your network.<\/li>\n<li>Go to <strong>Switching &gt; Monitor &gt; Switches<\/strong> and click the target switch from the inventory list.<\/li>\n<li>Locate the <strong>Power draw<\/strong> metric directly beneath the interactive switch faceplate diagram to view total consumption against the switch&#8217;s PoE budget (for example, <code>115 W \/ 740 W<\/code>).<\/li>\n<li>Look for the lightning bolt icon on individual ports in the faceplate diagram to identify active PoE links, or click any port and view the <strong>Power<\/strong> section to see real-time consumption in Watts and historical PoE usage graphs.<\/li>\n<\/ol>\n<p><strong>Key Takeaway:<\/strong> Graphical dashboards provide instant visual indicators of total PSU saturation and historical wattage trends without requiring CLI sessions.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Troubleshoot_and_Reset_PoE_on_a_Cisco_Switch_Port\"><\/span>How to Troubleshoot and Reset PoE on a Cisco Switch Port<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When your CLI or GUI checks reveal a port stuck in <code>off<\/code>, <code>faulty<\/code>, or <code>err-disable<\/code> status\u2014or when a connected camera or access point freezes\u2014follow these sequential steps to reset inline power and resolve delivery failures.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Power_Cycle_Reset_PoE_on_a_Single_Port\"><\/span>Step 1: Power Cycle (Reset) PoE on a Single Port<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>To remotely reboot a hung PoE device without disrupting the switch or climbing a ladder, toggle inline power on the specific interface:<\/p>\n<ol>\n<li>Enter global configuration mode and select the target port:<br \/>\n   <code>ios<br \/>\n   Switch# configure terminal<br \/>\n   Switch(config)# interface GigabitEthernet1\/0\/5<\/code><\/li>\n<li>Disable inline power, wait 5 seconds for the endpoint&#8217;s capacitors to fully discharge, and re-enable automatic PoE detection:<br \/>\n   <code>ios<br \/>\n   Switch(config-if)# power inline never<br \/>\n   Switch(config-if)# power inline auto<br \/>\n   Switch(config-if)# end<\/code><\/li>\n<\/ol>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Clear_a_PoE_err-disabled_inline-power_Port_State\"><\/span>Step 2: Clear a PoE <code>err-disabled<\/code> (<code>inline-power<\/code>) Port State<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If a device draws more wattage than its negotiated cutoff limit, the switch trips the port into an error-disabled state (logging <code>%ILPOWER-3-CONTROLLER_PORT_ERR<\/code> or <code>%ILPOWER-5-ILPOWER_POWER_DENY<\/code>).<\/p>\n<ol>\n<li>Verify that inline power policing caused the shutdown:<br \/>\n   <code>ios<br \/>\n   Switch# show interfaces status err-disabled<\/code><\/li>\n<li>Enter the interface configuration and either raise the allowed wattage ceiling or configure a static allocation if the device fails dynamic classification:<br \/>\n   <code>ios<br \/>\n   Switch# configure terminal<br \/>\n   Switch(config)# interface GigabitEthernet1\/0\/4<br \/>\n   Switch(config-if)# power inline auto max 30000<\/code><\/li>\n<li>Reset the interface to clear the <code>err-disabled<\/code> latch:<br \/>\n   <code>ios<br \/>\n   Switch(config-if)# shutdown<br \/>\n   Switch(config-if)# no shutdown<\/code><\/li>\n<li><em>(Optional)<\/em> Enable automatic recovery globally so the switch retries PoE delivery after a set interval:<br \/>\n   <code>ios<br \/>\n   Switch(config)# errdisable recovery cause inline-power<br \/>\n   Switch(config)# errdisable recovery interval 300<\/code><\/li>\n<\/ol>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Resolve_PoE_and_UPOE_Negotiation_Issues\"><\/span>Step 3: Resolve PoE+ and UPOE Negotiation Issues<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Devices requiring more than 15.4 W (Type 2 PoE+, Type 3 UPOE, or Type 4 UPOE+) often boot at low power and request additional wattage via Layer 2 discovery protocols after link-up.<\/p>\n<ol>\n<li>Ensure Link Layer Discovery Protocol (LLDP) or Cisco Discovery Protocol (CDP) is enabled globally and on the port:<br \/>\n   <code>ios<br \/>\n   Switch(config)# lldp run<br \/>\n   Switch(config)# cdp run<\/code><\/li>\n<li>For IEEE 802.3at Class 4 devices that do not support CDP\/LLDP power negotiation and instead rely on hardware 2-event physical layer classification, enable 2-event classification on the port:<br \/>\n   <code>ios<br \/>\n   Switch(config)# interface GigabitEthernet1\/0\/2<br \/>\n   Switch(config-if)# power inline port 2-event<\/code><\/li>\n<\/ol>\n<p><strong>Key Takeaway:<\/strong> Most PoE port failures stem from overcurrent policing or missing Layer 2 power negotiation (CDP\/LLDP) rather than failed switch hardware.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Cisco_IOS_and_IOS_XE_PoE_Command_Reference_and_Platform_Defaults\"><\/span>Cisco IOS and IOS XE PoE Command Reference and Platform Defaults<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>To standardize PoE behavior across enterprise deployments, administrators rely on Cisco IOS XE interface configuration parameters. The reference specifications below define default platform behaviors and command syntax for Cisco Catalyst switches.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Default_PoE_System_Parameters\"><\/span>Default PoE System Parameters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong>Inline Power Administrative Mode:<\/strong> Enabled (<code>auto<\/code>) on all PoE-capable interfaces by default.<\/li>\n<li><strong>Default Maximum Port Allocation:<\/strong> Determined dynamically by hardware capability (<code>15400 mW<\/code> on 802.3af switches, <code>30000 mW<\/code> on PoE+ switches, <code>60000 mW<\/code> on UPOE switches, and <code>90000 mW<\/code> on UPOE+ switches).<\/li>\n<li><strong>Power Policing (<code>power inline police<\/code>):<\/strong> Disabled by default; hardware controller cutoff protection remains active.<\/li>\n<li><strong>CDP \/ LLDP Power Negotiation:<\/strong> Enabled by default when CDP or LLDP is active on the interface.<\/li>\n<li><strong>Perpetual PoE and Fast PoE:<\/strong> Disabled by default.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Interface_PoE_Configuration_Command_Syntax\"><\/span>Interface PoE Configuration Command Syntax<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><code>power inline {auto [max max-wattage] | never | static [max max-wattage]}<\/code><\/li>\n<li><strong>Definition:<\/strong> Configures the PoE administrative state on an interface. <code>auto<\/code> powers the port upon PD detection and allocates power dynamically. <code>static<\/code> pre-allocates the specified maximum wattage (in milliwatts, from <code>4000<\/code> to <code>90000<\/code>) from the global budget even when no device is connected. <code>never<\/code> disables PoE detection and delivery.<\/li>\n<li><code>power inline police [action {errdisable | log}]<\/code><\/li>\n<li><strong>Definition:<\/strong> Enables real-time hardware monitoring of port power consumption against the administrative cutoff threshold. By default, exceeding the cutoff places the port into an <code>err-disabled<\/code> state; specifying <code>action log<\/code> logs a syslog warning message and restarts PoE on the port without disabling the data interface.<\/li>\n<li><code>power inline four-pair forced<\/code><\/li>\n<li><strong>Definition:<\/strong> Forces four-pair power delivery on UPOE\/UPOE+ interfaces for powered devices that require power across both spare and data pairs without standard IEEE 802.3bt negotiation.<\/li>\n<li><code>power inline port poe-ha<\/code><\/li>\n<li><strong>Definition:<\/strong> Enables Perpetual PoE on supported Catalyst 9000 Series switches, maintaining uninterrupted inline power to connected endpoints during a warm Cisco IOS XE software reload.<\/li>\n<li><code>power inline fast<\/code><\/li>\n<li><strong>Definition:<\/strong> Enables Fast PoE, allowing the switch to supply inline power to connected devices within seconds of cold AC power restoration before Cisco IOS XE finishes booting.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Official_Cisco_Documentation_Paths\"><\/span>Official Cisco Documentation Paths<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>For platform-specific hardware limits and release notes, consult the <strong>Interface and Hardware Component Configuration Guide<\/strong> (under the <em>Configuring Power over Ethernet<\/em> chapter) and the <strong>Interface and Hardware Component Command Reference<\/strong> matching your exact Cisco IOS XE release train (such as Cisco IOS XE 17.x for Catalyst 9200, 9300, and 9400 Series switches).<\/p>\n<p><strong>Key Takeaway:<\/strong> Understanding the distinction between <code>auto<\/code> and <code>static<\/code> allocation\u2014alongside features like Perpetual PoE\u2014ensures mission-critical endpoints retain guaranteed power during PSU failovers and switch reboots.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Best_Network_Monitoring_Tools_for_Tracking_Cisco_PoE_Usage_via_SNMP\"><\/span>Best Network Monitoring Tools for Tracking Cisco PoE Usage via SNMP<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Checking PoE status manually works well for single-switch troubleshooting, but managing dozens of wiring closets requires automated telemetry. By polling the standard <strong><code>POWER-ETHERNET-MIB<\/code><\/strong> (<code>1.3.6.1.2.1.105<\/code>) and Cisco&#8217;s proprietary <strong><code>CISCO-POWER-ETHERNET-EXT-MIB<\/code><\/strong> (<code>1.3.6.1.4.1.9.9.402<\/code>), network monitoring tools can continuously track power budgets and alert you before a switch runs out of PoE capacity:<\/p>\n<ol>\n<li><strong>Cisco Catalyst Center (formerly Cisco DNA Center):<\/strong> Provides native streaming telemetry and SNMP integration for Catalyst switches. Its PoE Assurance dashboards track real-time port load, verify Perpetual\/Fast PoE readiness, and trigger automated alerts when chassis power consumption approaches PSU redundancy thresholds.<\/li>\n<li><strong>SolarWinds Network Performance Monitor (NPM):<\/strong> Natively polls <code>pethMainPseConsumptionPower<\/code> and Cisco extended PoE OIDs out of the box. SolarWinds NPM displays module-level PoE saturation gauges and lets you build custom alerts when a switch exceeds 80% of its available inline power budget.<\/li>\n<li><strong>PRTG Network Monitor (Paessler):<\/strong> Features pre-configured SNMP Cisco System Health and PoE sensors that monitor per-module remaining wattage and per-port operational states (<code>pethPsePortDetectionStatus<\/code>), immediately notifying administrators when critical devices like security cameras lose PoE draw.<\/li>\n<li><strong>LibreNMS:<\/strong> A lightweight, open-source monitoring platform that automatically discovers <code>CISCO-POWER-ETHERNET-EXT-MIB<\/code> (<code>cpeExtPsePortPwrConsumption<\/code>) during device onboarding. LibreNMS generates historical per-port wattage RRD graphs right alongside standard interface bandwidth charts.<\/li>\n<li><strong>Zabbix:<\/strong> An enterprise open-source monitoring solution equipped with official Cisco IOS SNMP templates. Using Low-Level Discovery (LLD), Zabbix automatically enumerates PoE modules and ports, tracking PSU health, global wattage draw, and <code>err-disabled<\/code> PoE fault states across thousands of switches.<\/li>\n<\/ol>\n<p><strong>Key Takeaway:<\/strong> Pairing SNMP polling of <code>CISCO-POWER-ETHERNET-EXT-MIB<\/code> with an automated monitoring platform prevents unexpected PoE budget exhaustion when adding new powered endpoints to your network.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Checking PoE on a Cisco switch starts with verifying your hardware model&#8217;s capabilities and using <code>show power inline<\/code> (or the Web GUI) to compare real-time port consumption against your remaining switch power budget. By combining CLI diagnostics with proper CDP\/LLDP negotiation settings and automated SNMP monitoring, you can quickly recover faulted ports and maintain reliable power delivery across your entire network infrastructure.<\/p>\n<div class='sfsi_Sicons' style='width: 100%; display: inline-block; vertical-align: middle; text-align:left'><div style='margin:0px 8px 0px 0px; line-height: 24px'><span>Please follow and like us:<\/span><\/div><div class='sfsi_socialwpr'><div class='sf_fb_share sf_icon' style='text-align:left;vertical-align: middle;'><a href='https:\/\/www.facebook.com\/sharer\/sharer.php?u=https%3A%2F%2Fcciedump.spoto.net%2Fblog%2Fhow-to-check-poe-on-cisco-switch_24592.html' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Facebook Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/fbshare_bck.png'  \/><\/a><\/div><div class='sf_twiter sf_icon' style='display: inline-block;vertical-align: middle;width: auto;margin-left: 7px;'>\r\n\t\t\t\t\t\t<a target='_blank' href='https:\/\/twitter.com\/intent\/tweet?text=How+to+Check+PoE+on+Cisco+Switch+https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html'style='display:inline-block' >\r\n\t\t\t\t\t\t\t<img data-pin-nopin= true width='auto' class='sfsi_wicon' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/en_US_Tweet.svg' alt='Tweet' title='Tweet' >\r\n\t\t\t\t\t\t<\/a>\r\n\t\t\t\t\t<\/div><div class='sf_pinit sf_icon' style='text-align:left;vertical-align: middle;float:left;line-height: 33px;width:auto;margin: 0 -2px;'><a href='#'  onclick='sfsi_pinterest_modal_images(event,\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\",\"How to Check PoE on Cisco Switch\")' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Pin Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/share_icons\/Pinterest_Save\/en_US_save.svg'  \/><\/a><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Managing wireless access points, IP phones, and security cameras requires clear visibility into how much electrical power your network switches are supplying. Whether you are planning new device deployments or diagnosing why a connected device refuses to boot, knowing how to check Power over Ethernet (PoE) on a Cisco switch allows you to track per-port&#8230; &raquo; <a class=\"read-more-link\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\">read more<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,608],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Check PoE on Cisco Switch - SPOTO Official Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Check PoE on Cisco Switch - SPOTO Official Blog\" \/>\n<meta property=\"og:description\" content=\"Managing wireless access points, IP phones, and security cameras requires clear visibility into how much electrical power your network switches are supplying. Whether you are planning new device deployments or diagnosing why a connected device refuses to boot, knowing how to check Power over Ethernet (PoE) on a Cisco switch allows you to track per-port... &raquo; read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\" \/>\n<meta property=\"og:site_name\" content=\"SPOTO Official Blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T09:02:06+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"SPOTO \u7f16\u8f91\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\",\"name\":\"SPOTO Club\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"caption\":\"SPOTO Club\"},\"logo\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\"},\"description\":\"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205\",\"sameAs\":[\"https:\/\/cciedump.spoto.net\/\"]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/\",\"name\":\"SPOTO Official Blog\",\"description\":\"Focus on Online IT Training for 20+ Years\",\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#webpage\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\",\"name\":\"How to Check PoE on Cisco Switch - SPOTO Official Blog\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\"},\"datePublished\":\"2026-11-17T09:02:06+00:00\",\"dateModified\":\"2026-11-17T09:02:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cciedump.spoto.net\/blog\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Check PoE on Cisco Switch\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#article\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#webpage\"},\"author\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\"},\"headline\":\"How to Check PoE on Cisco Switch\",\"datePublished\":\"2026-11-17T09:02:06+00:00\",\"dateModified\":\"2026-11-17T09:02:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#webpage\"},\"wordCount\":1791,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"articleSection\":[\"CCNA Certification\",\"Cisco Certification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\",\"name\":\"SPOTO \u7f16\u8f91\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"caption\":\"SPOTO \u7f16\u8f91\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Check PoE on Cisco Switch - SPOTO Official Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html","og_locale":"en_US","og_type":"article","og_title":"How to Check PoE on Cisco Switch - SPOTO Official Blog","og_description":"Managing wireless access points, IP phones, and security cameras requires clear visibility into how much electrical power your network switches are supplying. Whether you are planning new device deployments or diagnosing why a connected device refuses to boot, knowing how to check Power over Ethernet (PoE) on a Cisco switch allows you to track per-port... &raquo; read more","og_url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html","og_site_name":"SPOTO Official Blog","article_published_time":"2026-11-17T09:02:06+00:00","twitter_card":"summary_large_image","twitter_misc":{"Written by":"SPOTO \u7f16\u8f91","Est. reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Person","Organization"],"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638","name":"SPOTO Club","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","caption":"SPOTO Club"},"logo":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo"},"description":"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205","sameAs":["https:\/\/cciedump.spoto.net\/"]},{"@type":"WebSite","@id":"https:\/\/cciedump.spoto.net\/blog\/#website","url":"https:\/\/cciedump.spoto.net\/blog\/","name":"SPOTO Official Blog","description":"Focus on Online IT Training for 20+ Years","publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#webpage","url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html","name":"How to Check PoE on Cisco Switch - SPOTO Official Blog","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#website"},"datePublished":"2026-11-17T09:02:06+00:00","dateModified":"2026-11-17T09:02:06+00:00","breadcrumb":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cciedump.spoto.net\/blog"},{"@type":"ListItem","position":2,"name":"How to Check PoE on Cisco Switch"}]},{"@type":"Article","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#article","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#webpage"},"author":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1"},"headline":"How to Check PoE on Cisco Switch","datePublished":"2026-11-17T09:02:06+00:00","dateModified":"2026-11-17T09:02:06+00:00","mainEntityOfPage":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#webpage"},"wordCount":1791,"commentCount":0,"publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"articleSection":["CCNA Certification","Cisco Certification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-poe-on-cisco-switch_24592.html#respond"]}]},{"@type":"Person","@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1","name":"SPOTO \u7f16\u8f91","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","caption":"SPOTO \u7f16\u8f91"}}]}},"_links":{"self":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24592"}],"collection":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/comments?post=24592"}],"version-history":[{"count":0,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24592\/revisions"}],"wp:attachment":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/media?parent=24592"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/categories?post=24592"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/tags?post=24592"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}