{"id":24587,"date":"2026-11-17T15:48:13","date_gmt":"2026-11-17T07:48:13","guid":{"rendered":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html"},"modified":"2026-11-17T15:48:13","modified_gmt":"2026-11-17T07:48:13","slug":"how-to-check-loop-in-cisco-switch","status":"publish","type":"post","link":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html","title":{"rendered":"How to Check Loop in Cisco Switch"},"content":{"rendered":"<p>A Layer 2 switching loop is one of the most disruptive failures a network administrator can face. Because Ethernet frames lack a Time-to-Live (TTL) header field, broadcast, multicast, and unknown unicast frames caught in a physical or logical loop circulate endlessly at line rate. Within seconds, a single miswired patch cable or malfunctioning downstream switch can saturate inter-switch trunks, corrupt the Content Addressable Memory (CAM) table, and exhaust the switch&#8217;s control-plane CPU.<\/p>\n<p>Quickly isolating a loop on a Cisco Catalyst or Nexus switch requires knowing what telemetry to look for, which CLI commands trace traffic back to the physical port, and how to harden the switch against future topology failures.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_17 counter-hierarchy counter-decimal ez-toc-light-blue\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" style=\"display: none;\"><i class=\"ez-toc-glyphicon ez-toc-icon-toggle\"><\/i><\/a><\/span><\/div>\n<nav><ul class=\"ez-toc-list ez-toc-list-level-1\"><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Identifying_Cisco_Switch_Loop_Symptoms_Logs_LEDs_and_CPU_Spikes\" title=\"Identifying Cisco Switch Loop Symptoms: Logs, LEDs, and CPU Spikes\">Identifying Cisco Switch Loop Symptoms: Logs, LEDs, and CPU Spikes<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#What_does_the_SW_MATM-4-MACFLAP_NOTIF_syslog_message_mean\" title=\"What does the %SW_MATM-4-MACFLAP_NOTIF syslog message mean?\">What does the %SW_MATM-4-MACFLAP_NOTIF syslog message mean?<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#What_physical_LED_patterns_indicate_a_switching_loop_on_a_Cisco_Catalyst_switch\" title=\"What physical LED patterns indicate a switching loop on a Cisco Catalyst switch?\">What physical LED patterns indicate a switching loop on a Cisco Catalyst switch?<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#How_can_I_confirm_if_high_CPU_utilization_is_caused_by_a_network_loop\" title=\"How can I confirm if high CPU utilization is caused by a network loop?\">How can I confirm if high CPU utilization is caused by a network loop?<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step-by-Step_CLI_Guide_to_Detect_and_Trace_a_Network_Loop\" title=\"Step-by-Step CLI Guide to Detect and Trace a Network Loop\">Step-by-Step CLI Guide to Detect and Trace a Network Loop<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_1_Verify_CPU_Load_and_Isolate_Top_Processes\" title=\"Step 1: Verify CPU Load and Isolate Top Processes\">Step 1: Verify CPU Load and Isolate Top Processes<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_2_Check_the_Syslog_Buffer_for_Flapping_Ports_and_VLANs\" title=\"Step 2: Check the Syslog Buffer for Flapping Ports and VLANs\">Step 2: Check the Syslog Buffer for Flapping Ports and VLANs<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_3_Track_Spanning_Tree_Topology_Change_Notifications_TCNs\" title=\"Step 3: Track Spanning Tree Topology Change Notifications (TCNs)\">Step 3: Track Spanning Tree Topology Change Notifications (TCNs)<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_4_Inspect_Interface_Broadcast_Counters_and_Bandwidth_Rates\" title=\"Step 4: Inspect Interface Broadcast Counters and Bandwidth Rates\">Step 4: Inspect Interface Broadcast Counters and Bandwidth Rates<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_5_Trace_Downstream_Neighbors_and_Shut_Down_the_Source_Port\" title=\"Step 5: Trace Downstream Neighbors and Shut Down the Source Port\">Step 5: Trace Downstream Neighbors and Shut Down the Source Port<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Troubleshooting_Self-Loops_Caused_by_Downstream_Unmanaged_Switches\" title=\"Troubleshooting Self-Loops Caused by Downstream Unmanaged Switches\">Troubleshooting Self-Loops Caused by Downstream Unmanaged Switches<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_1_Identify_Access_Ports_Learning_Multiple_MAC_Addresses\" title=\"Step 1: Identify Access Ports Learning Multiple MAC Addresses\">Step 1: Identify Access Ports Learning Multiple MAC Addresses<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_2_Compare_Input_vs_Output_Broadcast_Counters_on_Access_Ports\" title=\"Step 2: Compare Input vs. Output Broadcast Counters on Access Ports\">Step 2: Compare Input vs. Output Broadcast Counters on Access Ports<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_3_Check_for_Self-Looped_STP_Peer_States_Shr_or_BKN\" title=\"Step 3: Check for Self-Looped STP Peer States (Shr or BKN*)\">Step 3: Check for Self-Looped STP Peer States (Shr or BKN*)<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Step_4_Run_Cable_Diagnostics_TDR_if_No_Traffic_Passes\" title=\"Step 4: Run Cable Diagnostics (TDR) if No Traffic Passes\">Step 4: Run Cable Diagnostics (TDR) if No Traffic Passes<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Comparing_Cisco_Loop_Prevention_Features_BPDU_Guard_vs_Loop_Guard_vs_Root_Guard_vs_UDLD\" title=\"Comparing Cisco Loop Prevention Features: BPDU Guard vs. Loop Guard vs. Root Guard vs. UDLD\">Comparing Cisco Loop Prevention Features: BPDU Guard vs. Loop Guard vs. Root Guard vs. UDLD<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Configuration_Templates_BPDU_Guard_Loop_Guard_and_Storm_Control\" title=\"Configuration Templates: BPDU Guard, Loop Guard, and Storm Control\">Configuration Templates: BPDU Guard, Loop Guard, and Storm Control<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#1_Global_STP_Hardening_and_Auto-Recovery_Template\" title=\"1. Global STP Hardening and Auto-Recovery Template\">1. Global STP Hardening and Auto-Recovery Template<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#2_Access_Port_Loop_Broadcast_Storm_Protection_Template\" title=\"2. Access Port Loop &amp; Broadcast Storm Protection Template\">2. Access Port Loop &amp; Broadcast Storm Protection Template<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#3_Uplink_Trunk_Port_Protection_Template\" title=\"3. Uplink \/ Trunk Port Protection Template\">3. Uplink \/ Trunk Port Protection Template<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Verification_Commands\" title=\"Verification Commands\">Verification Commands<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Cisco_Official_Documentation_and_TAC_STP_Diagnostic_Reference\" title=\"Cisco Official Documentation and TAC STP Diagnostic Reference\">Cisco Official Documentation and TAC STP Diagnostic Reference<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Official_Cisco_Technical_Documentation_References\" title=\"Official Cisco Technical Documentation References\">Official Cisco Technical Documentation References<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Cisco_TAC_Escalation_Data_Collection_Specification\" title=\"Cisco TAC Escalation Data Collection Specification\">Cisco TAC Escalation Data Collection Specification<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Identifying_Cisco_Switch_Loop_Symptoms_Logs_LEDs_and_CPU_Spikes\"><\/span>Identifying Cisco Switch Loop Symptoms: Logs, LEDs, and CPU Spikes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Before running invasive port isolation, verifying whether performance degradation is actually caused by a Layer 2 bridging loop saves valuable troubleshooting time. The following frequently asked questions break down the primary hardware and software indicators of an active loop.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_does_the_SW_MATM-4-MACFLAP_NOTIF_syslog_message_mean\"><\/span>What does the <code>%SW_MATM-4-MACFLAP_NOTIF<\/code> syslog message mean?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>This warning (often displayed as <code>%FMANFP-4-MACFLAP_NOTIF<\/code> on newer Catalyst 9000 IOS-XE platforms or <code>%MAC_MOVE-SP-4-NOTIF<\/code> on modular chassis) indicates that the switch is rapidly learning the exact same source MAC address on two or more different physical interfaces within the same VLAN:<\/p>\n<pre><code class=\"language-text\">%SW_MATM-4-MACFLAP_NOTIF: Host 0050.56c0.0008 in vlan 10 is flapping between port Gi1\/0\/1 and port Gi1\/0\/24\n<\/code><\/pre>\n<p>While occasional MAC flaps can occur legitimately due to misconfigured server NIC teaming or wireless roaming, continuous, high-frequency flapping across multiple host MAC addresses is the definitive signature of a bridging loop circulating frames across multiple paths.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_physical_LED_patterns_indicate_a_switching_loop_on_a_Cisco_Catalyst_switch\"><\/span>What physical LED patterns indicate a switching loop on a Cisco Catalyst switch?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Under normal operating conditions, access and trunk port LEDs blink irregularly in proportion to network traffic. During a broadcast storm caused by a loop, the status LEDs across all ports assigned to the affected VLAN will lock into a rapid, synchronized strobe or appear solid green\/amber simultaneously. On switches with a <strong>Mode<\/strong> button placed in <code>STAT<\/code> or <code>UTIL<\/code> mode, the front-panel LED bar graph will surge toward 100% backplane utilization.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"How_can_I_confirm_if_high_CPU_utilization_is_caused_by_a_network_loop\"><\/span>How can I confirm if high CPU utilization is caused by a network loop?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>When looped broadcast and multicast packets flood a VLAN, the switch hardware forwards copies of those frames to the supervisor CPU for software processing (such as ARP inspection, DHCP snooping, and Spanning Tree BPDU handling). You can differentiate a loop-induced CPU spike from a routing or management process issue by inspecting three indicators in <code>show processes cpu<\/code>:<br \/>\n1. <strong>High Interrupt Percentage:<\/strong> Look at the header line <code>CPU utilization for five seconds: X%\/Y%<\/code>. In <code>X%\/Y%<\/code>, <code>X<\/code> represents total CPU usage and <code>Y<\/code> represents CPU time spent handling hardware network interrupts. If <code>Y<\/code> is unusually high (for example, <code>98%\/65%<\/code>), the CPU is being overwhelmed by punted network packets rather than background tasks.<br \/>\n2. <strong>Spiking Control-Plane Processes:<\/strong> Look for elevated consumption in <code>ARP Input<\/code>, <code>IP Input<\/code>, <code>Spanning Tree<\/code>, or platform-specific packet-punting processes such as <code>fed punject<\/code> (IOS-XE) or <code>Hulc LED Process<\/code>.<br \/>\n3. <strong>Control Plane Policing (CoPP) Drops:<\/strong> On IOS-XE switches, running <code>show platform hardware fed switch active qos queue stats internal cpu policer<\/code> will reveal heavy packet drops on the broadcast and ARP CPU queues.<\/p>\n<p><strong>Key Takeaway:<\/strong> Synchronized port LED strobing combined with high interrupt-driven CPU usage and <code>%SW_MATM-4-MACFLAP_NOTIF<\/code> syslog alerts confirms an active Layer 2 broadcast storm.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Step-by-Step_CLI_Guide_to_Detect_and_Trace_a_Network_Loop\"><\/span>Step-by-Step CLI Guide to Detect and Trace a Network Loop<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Once you confirm the symptoms of a switching loop, use the Cisco IOS\/IOS-XE CLI to trace the storm from the core or distribution layer down to the exact physical edge port. <\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Verify_CPU_Load_and_Isolate_Top_Processes\"><\/span>Step 1: Verify CPU Load and Isolate Top Processes<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Log in via the out-of-band console port if SSH\/Telnet sessions are timing out, and verify the control plane status:<\/p>\n<pre><code class=\"language-ios\">Switch# show processes cpu sorted | exclude 0.00\nCPU utilization for five seconds: 96%\/54%; one minute: 92%; five minutes: 89%\n PID Runtime(ms)     Invoked      uSecs   5Sec   1Min   5Min TTY Process\n 142      849210     2910422        291 34.12% 31.05% 28.90%   0 ARP Input\n 189      410230     1502110        273 14.50% 13.80% 12.40%   0 Spanning Tree\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Check_the_Syslog_Buffer_for_Flapping_Ports_and_VLANs\"><\/span>Step 2: Check the Syslog Buffer for Flapping Ports and VLANs<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Query the local logging buffer to identify which VLAN is experiencing instability and which interfaces are disputing MAC ownership:<\/p>\n<pre><code class=\"language-ios\">Switch# show logging | include MACFLAP|SPANTREE\n<\/code><\/pre>\n<p>Look at the two ports listed in the <code>MACFLAP_NOTIF<\/code> entries. If both ports are uplinks\/trunks (<code>Po1<\/code> and <code>Gi1\/0\/48<\/code>), the loop exists further downstream. If one is an uplink and the other is a local access port (<code>Gi1\/0\/15<\/code>), the loop is entering through <code>Gi1\/0\/15<\/code>.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Track_Spanning_Tree_Topology_Change_Notifications_TCNs\"><\/span>Step 3: Track Spanning Tree Topology Change Notifications (TCNs)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Rapidly recurring STP topology changes flush the CAM table and worsen flooding. Run the following command to identify which interface is resetting the topology timer and flooding TCNs into the VLAN:<\/p>\n<pre><code class=\"language-ios\">Switch# show spanning-tree vlan 10 detail | include ieee|from|occurred|changes\n  VLAN0010 is executing the ieee compatible Spanning Tree protocol\n  Number of topology changes 482 last change occurred 00:00:02 ago\n          from GigabitEthernet1\/0\/15\n<\/code><\/pre>\n<p>The port listed after <code>from<\/code> indicates the exact direction from which the topology instability is originating.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_4_Inspect_Interface_Broadcast_Counters_and_Bandwidth_Rates\"><\/span>Step 4: Inspect Interface Broadcast Counters and Bandwidth Rates<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If syslog is suppressed or disabled, locate the offending port by comparing input broadcast\/multicast packet counters across all active interfaces:<\/p>\n<pre><code class=\"language-ios\">Switch# show interfaces counters\nPort            InOctets    InUcastPkts    InMcastPkts    InBcastPkts\nGi1\/0\/1          4502190          34102           1204            450\nGi1\/0\/15     98451204912          12045       45102930      894120411\nGi1\/0\/48     98910294100         450192       45104100      894125102\n<\/code><\/pre>\n<p>In the output above, <code>Gi1\/0\/15<\/code> (an access port) has an astronomical <code>InBcastPkts<\/code> count matching the uplink <code>Gi1\/0\/48<\/code>. You can verify its real-time packet-per-second (pps) ingress rate with:<\/p>\n<pre><code class=\"language-ios\">Switch# show interfaces GigabitEthernet1\/0\/15 | include line protocol|input rate|broadcasts\n  GigabitEthernet1\/0\/15 is up, line protocol is up (connected)\n  5 minute input rate 842105000 bits\/sec, 141200 packets\/sec\n  Received 894120411 broadcasts (0 IP multicasts)\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_5_Trace_Downstream_Neighbors_and_Shut_Down_the_Source_Port\"><\/span>Step 5: Trace Downstream Neighbors and Shut Down the Source Port<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Before disabling the interface, check whether it leads to another managed Cisco switch or directly to an endpoint:<\/p>\n<pre><code class=\"language-ios\">Switch# show cdp neighbors GigabitEthernet1\/0\/15 detail\n<\/code><\/pre>\n<p>If CDP returns another managed switch, SSH into that neighbor and repeat Steps 2 through 4 until you reach an edge port with no CDP neighbor. Once you isolate the edge interface, administratively shut it down to break the loop and verify that CPU utilization returns to normal:<\/p>\n<pre><code class=\"language-ios\">Switch# configure terminal\nSwitch(config)# interface GigabitEthernet1\/0\/15\nSwitch(config-if)# shutdown\nSwitch(config-if)# end\n<\/code><\/pre>\n<p><strong>Key Takeaway:<\/strong> Following the trail of <code>MACFLAP_NOTIF<\/code> logs, STP TCN origins, and <code>InBcastPkts<\/code> counters from core trunks down to non-CDP edge ports reliably isolates multi-port switching loops.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Troubleshooting_Self-Loops_Caused_by_Downstream_Unmanaged_Switches\"><\/span>Troubleshooting Self-Loops Caused by Downstream Unmanaged Switches<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>While the standard CLI workflow above catches loops spanning two or more Cisco ports, a notorious edge case occurs when a user plugs both ends of a patch cable into a small, unmanaged desktop switch connected to a <strong>single<\/strong> Cisco access port.<\/p>\n<p>Because all looped frames bounce inside the unmanaged switch and re-enter the Cisco switch on the exact same physical interface, <strong>the Cisco switch will not generate <code>%SW_MATM-4-MACFLAP_NOTIF<\/code> errors<\/strong> (the MAC address never changes ports on the Cisco switch). Furthermore, many cheap unmanaged switches either strip\/drop IEEE <code>0180.c200.0000<\/code> STP BPDUs or fail to process them, allowing a severe broadcast storm to erupt on a single access port before standard STP can intervene.<\/p>\n<p>Follow these steps to isolate a downstream unmanaged switch loop:<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Identify_Access_Ports_Learning_Multiple_MAC_Addresses\"><\/span>Step 1: Identify Access Ports Learning Multiple MAC Addresses<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>An access port wired to a single workstation or IP phone should only have one or two dynamic MAC addresses. Scan the CAM table on the suspect access port to confirm if a hub or unmanaged switch is attached:<\/p>\n<pre><code class=\"language-ios\">Switch# show mac address-table dynamic interface GigabitEthernet1\/0\/22\n          Mac Address Table\n-------------------------------------------\nVlan    Mac Address       Type        Ports\n----    -----------       ----        -----\n  10    001b.214a.9c01    DYNAMIC     Gi1\/0\/22\n  10    0024.e83b.1109    DYNAMIC     Gi1\/0\/22\n  10    dc4a.3e77.8012    DYNAMIC     Gi1\/0\/22\n  10    f01f.af44.029a    DYNAMIC     Gi1\/0\/22\nTotal Mac Addresses for this criterion: 4\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Compare_Input_vs_Output_Broadcast_Counters_on_Access_Ports\"><\/span>Step 2: Compare Input vs. Output Broadcast Counters on Access Ports<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>When a downstream unmanaged switch is self-looped, it amplifies every broadcast sent out by the Cisco switch and reflects it straight back into the same Cisco port. Run <code>show interfaces counters<\/code> and look for an access port where <strong>Input Broadcasts (<code>InBcastPkts<\/code>) vastly outnumber Output Broadcasts (<code>OutBcastPkts<\/code>)<\/strong>, whereas every other normal access port in that VLAN exhibits high <code>OutBcastPkts<\/code> (receiving the flooded storm from the switch backplane) and very low <code>InBcastPkts<\/code>:<\/p>\n<pre><code class=\"language-ios\">Switch# show interfaces GigabitEthernet1\/0\/22 counters\nPort            InOctets    InUcastPkts    InMcastPkts    InBcastPkts\nGi1\/0\/22     45120941023           4102        8910240      142910455\n\nPort           OutOctets   OutUcastPkts   OutMcastPkts   OutBcastPkts\nGi1\/0\/22       812049102           3890         120410        1420110\n<\/code><\/pre>\n<p>Here, <code>Gi1\/0\/22<\/code> is injecting over 142 million broadcast frames <em>into<\/em> the Cisco switch\u2014confirming it is the origin of the self-loop.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Check_for_Self-Looped_STP_Peer_States_Shr_or_BKN\"><\/span>Step 3: Check for Self-Looped STP Peer States (<code>Shr<\/code> or <code>BKN*<\/code>)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If the unmanaged switch passively floods Cisco BPDUs back into the sending Cisco port without stripping them, the Cisco switch will hear its own BPDU on the same interface. Check the <code>Type<\/code> column in <code>show spanning-tree<\/code>:<\/p>\n<pre><code class=\"language-ios\">Switch# show spanning-tree interface GigabitEthernet1\/0\/22\nVlan                Role Sts Cost      Prio.Nbr Type\n------------------- ---- --- --------- -------- --------------------------------\nVLAN0010            Desg BKN*19        128.22   Shr *LOOP_Inc\n<\/code><\/pre>\n<p>If an interface transitions from <code>P2p<\/code> (Point-to-Point) to <code>Shr<\/code> (Shared) or displays <code>BKN*<\/code> (Broken), the Cisco port has detected its own reflected BPDUs downstream.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_4_Run_Cable_Diagnostics_TDR_if_No_Traffic_Passes\"><\/span>Step 4: Run Cable Diagnostics (TDR) if No Traffic Passes<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If the downstream loop completely locks up the unmanaged switch&#8217;s ASICs, you can verify whether an active powered device is still attached at the end of the drop using built-in Time Domain Reflectometry:<\/p>\n<pre><code class=\"language-ios\">Switch# test cable-diagnostics tdr interface GigabitEthernet1\/0\/22\nSwitch# show cable-diagnostics tdr interface GigabitEthernet1\/0\/22\n<\/code><\/pre>\n<p>A <code>Normal<\/code> pair termination at a short distance combined with high ingress broadcasts confirms an active rogue switch at the desk location.<\/p>\n<p><strong>Key Takeaway:<\/strong> When a broadcast storm occurs without MAC flapping logs, look for an access port with multiple learned MAC addresses and high <code>InBcastPkts<\/code> relative to <code>OutBcastPkts<\/code> to uncover a self-looped unmanaged switch.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Comparing_Cisco_Loop_Prevention_Features_BPDU_Guard_vs_Loop_Guard_vs_Root_Guard_vs_UDLD\"><\/span>Comparing Cisco Loop Prevention Features: BPDU Guard vs. Loop Guard vs. Root Guard vs. UDLD<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Reactive troubleshooting stops an active outage, but preventing loops entirely requires selecting the right Cisco Layer 2 protection mechanism for each failure mode. Because Spanning Tree relies on continuous bidirectional BPDU exchange, different hardware or cabling failures require distinct safeguards.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Feature<\/th>\n<th style=\"text-align: left;\">Primary Failure Mode Addressed<\/th>\n<th style=\"text-align: left;\">Target Interfaces<\/th>\n<th style=\"text-align: left;\">Trigger Condition<\/th>\n<th style=\"text-align: left;\">Action Taken (Port State)<\/th>\n<th style=\"text-align: left;\">Recovery Mechanism<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>BPDU Guard<\/strong><\/td>\n<td style=\"text-align: left;\">Rogue switches plugged into user wall jacks or self-looped unmanaged switches flooding BPDUs back to the access port.<\/td>\n<td style=\"text-align: left;\">Access ports with <strong>PortFast<\/strong> enabled.<\/td>\n<td style=\"text-align: left;\">Receipt of <em>any<\/em> STP BPDU (superior or inferior) on the protected interface.<\/td>\n<td style=\"text-align: left;\">Places the physical port immediately into <code>err-disabled<\/code> state (shuts down all traffic).<\/td>\n<td style=\"text-align: left;\">Manual <code>shutdown<\/code> \/ <code>no shutdown<\/code> or automated timer via <code>errdisable recovery cause bpduguard<\/code>.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Loop Guard<\/strong><\/td>\n<td style=\"text-align: left;\">Software failure on a neighbor switch or unidirectional link failure where a blocking port stops receiving BPDUs and prematurely transitions to Forwarding.<\/td>\n<td style=\"text-align: left;\">Non-designated STP ports (Root, Alternate, and Backup ports) on <strong>inter-switch trunks<\/strong>.<\/td>\n<td style=\"text-align: left;\">Sudden absence of incoming BPDUs and expiration of the STP Max Age timer on a blocking port.<\/td>\n<td style=\"text-align: left;\">Places the affected VLAN on the port into <code>loop-inconsistent<\/code> (blocking) state.<\/td>\n<td style=\"text-align: left;\">Automatic recovery immediately upon receiving a valid BPDU on the interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Root Guard<\/strong><\/td>\n<td style=\"text-align: left;\">Rogue or misconfigured switch with a lower bridge priority attempting to hijack the STP Root Bridge role and alter trunk forwarding paths.<\/td>\n<td style=\"text-align: left;\">Designated <strong>distribution\/core ports<\/strong> facing downstream access or customer switches.<\/td>\n<td style=\"text-align: left;\">Receipt of a <em>superior<\/em> BPDU claiming a better Root Bridge ID.<\/td>\n<td style=\"text-align: left;\">Places the interface into <code>root-inconsistent<\/code> (blocking) state for the affected VLAN.<\/td>\n<td style=\"text-align: left;\">Automatic recovery as soon as the port stops receiving superior BPDUs and the message age expires.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>UDLD (Aggressive)<\/strong><\/td>\n<td style=\"text-align: left;\">Physical one-way fiber faults (damaged TX or RX strand) or miswired patch panels where Layer 1 link pulses stay up, blinding STP to a loop.<\/td>\n<td style=\"text-align: left;\"><strong>Fiber-optic uplinks<\/strong> and Port-Channel member links.<\/td>\n<td style=\"text-align: left;\">Loss of bidirectional Layer 2 echo acknowledgments from the neighbor for 8 consecutive seconds.<\/td>\n<td style=\"text-align: left;\">Places the physical port into <code>err-disabled<\/code> state.<\/td>\n<td style=\"text-align: left;\">Manual intervention or automated timer via <code>errdisable recovery cause udld<\/code>.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Key Takeaway:<\/strong> Use BPDU Guard on edge access ports to block rogue switches, and combine Loop Guard with Aggressive UDLD on inter-switch fiber trunks to protect against unidirectional link failures and missing BPDUs.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Configuration_Templates_BPDU_Guard_Loop_Guard_and_Storm_Control\"><\/span>Configuration Templates: BPDU Guard, Loop Guard, and Storm Control<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>To harden your Cisco Catalyst switch against both multi-port bridging loops and unmanaged switch broadcast storms, deploy the following IOS\/IOS-XE configuration templates.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"1_Global_STP_Hardening_and_Auto-Recovery_Template\"><\/span>1. Global STP Hardening and Auto-Recovery Template<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Enable Rapid-PVST+, enforce PortFast and BPDU Guard globally on all access ports by default, and configure <code>errdisable<\/code> auto-recovery so ports automatically test recovery after 5 minutes (300 seconds):<\/p>\n<pre><code class=\"language-ios\">! Configure Rapid-PVST+ and global PortFast \/ BPDU Guard defaults\nspanning-tree mode rapid-pvst\nspanning-tree extend system-id\nspanning-tree portfast edge default\nspanning-tree portfast edge bpduguard default\n\n! Enable automatic recovery for BPDU Guard, Storm Control, and UDLD events\nerrdisable recovery cause bpduguard\nerrdisable recovery cause storm-control\nerrdisable recovery cause udld\nerrdisable recovery cause loopback\nerrdisable recovery interval 300\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"2_Access_Port_Loop_Broadcast_Storm_Protection_Template\"><\/span>2. Access Port Loop &amp; Broadcast Storm Protection Template<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Apply explicit BPDU Guard and hardware <strong>Storm Control<\/strong> to user-facing ports. If an unmanaged downstream switch strips BPDUs and causes a self-loop, Storm Control acts as the failsafe by shutting down (<code>err-disable<\/code>) the access port as soon as ingress broadcast or multicast traffic exceeds 10% of link capacity:<\/p>\n<pre><code class=\"language-ios\">interface range GigabitEthernet1\/0\/1 - 44\n description User_Access_Ports\n switchport mode access\n switchport nonegotiate\n ! Explicitly enforce Edge PortFast and BPDU Guard\n spanning-tree portfast edge\n spanning-tree bpduguard enable\n ! Configure Storm Control thresholds (% of total interface bandwidth)\n storm-control broadcast level 10.00 5.00\n storm-control multicast level 10.00 5.00\n storm-control unicast level 80.00 70.00\n ! Shut down (err-disable) the port or trap when threshold is exceeded\n storm-control action shutdown\n storm-control action trap\n exit\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"3_Uplink_Trunk_Port_Protection_Template\"><\/span>3. Uplink \/ Trunk Port Protection Template<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Apply Loop Guard and Aggressive UDLD to fiber uplinks and inter-switch trunks to prevent unidirectional link loops:<\/p>\n<pre><code class=\"language-ios\">interface range TenGigabitEthernet1\/1\/1 - 4\n description Distribution_Uplink_Trunks\n switchport mode trunk\n ! Protect against missing BPDUs on blocking\/alternate paths\n spanning-tree guard loop\n ! Protect against physical one-way fiber faults\n udld port aggressive\n exit\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Verification_Commands\"><\/span>Verification Commands<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Verify your active loop protection settings with the following operational commands:<\/p>\n<pre><code class=\"language-ios\">show spanning-tree summary\nshow errdisable recovery\nshow storm-control broadcast\nshow udld neighbors\n<\/code><\/pre>\n<p><strong>Key Takeaway:<\/strong> Pairing <code>spanning-tree bpduguard enable<\/code> with <code>storm-control action shutdown<\/code> on access ports guarantees automatic port isolation whether a downstream loop forwards BPDUs or strips them.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Cisco_Official_Documentation_and_TAC_STP_Diagnostic_Reference\"><\/span>Cisco Official Documentation and TAC STP Diagnostic Reference<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When standard CLI isolation and port hardening do not resolve recurring Spanning Tree instabilities on Cisco Catalyst (IOS-XE) or Cisco Nexus (NX-OS) platforms, consult the official Cisco Technical Assistance Center (TAC) diagnostic architecture and authoritative references below.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Official_Cisco_Technical_Documentation_References\"><\/span>Official Cisco Technical Documentation References<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong>Troubleshoot STP Problems and Related Design Considerations<\/strong> \u2014 <em>Cisco Document ID: 10556<\/em><br \/>\n  Defines the canonical Cisco methodology for diagnosing bridging loops, corrupt BPDUs, unidirectional links, and PortFast misconfigurations across Catalyst switches.<\/li>\n<li><strong>Understand and Configure Spanning Tree Protocol (STP) Enhancements (Loop Guard, Root Guard, BPDU Guard)<\/strong> \u2014 <em>Cisco Document ID: 65884 \/ 10588<\/em><br \/>\n  Details state-machine behavior and hardware ASIC interaction for STP guard enhancements.<\/li>\n<li><strong>Cisco Catalyst 9000 Series Switches Layer 2 Configuration Guide (Cisco IOS-XE)<\/strong><br \/>\n  Provides platform-specific guidelines for Unified Access Data Plane (UADP) ASIC packet punting, hardware MAC learning limits, and Federated Manager (<code>FMAN<\/code>) MAC flap notification dampening.<\/li>\n<li><strong>Cisco Nexus 9000 Series NX-OS Layer 2 Switching Configuration Guide (BA\/STP Dispute &amp; MAC Move Loop Detection)<\/strong><br \/>\n  Covers NX-OS specific loop mitigation mechanisms, including <code>spanning-tree loopguard default<\/code> and <code>mac address-table loop-detection<\/code> for VXLAN and classical Ethernet fabrics.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Cisco_TAC_Escalation_Data_Collection_Specification\"><\/span>Cisco TAC Escalation Data Collection Specification<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Prior to resetting a switch or opening a Severity 1\/2 Service Request with Cisco TAC for an unexplained STP failure, capture the following non-disruptive diagnostic output while the symptom is active (or immediately following recovery):<\/p>\n<ol>\n<li><strong>Comprehensive System and STP State:<\/strong><\/li>\n<li><code>show tech-support spanning-tree<\/code> (captures STP state machines, port roles, and internal event histories without outputting full system configuration noise).<\/li>\n<li><code>show spanning-tree internal event-history tree &lt;vlan-id&gt;<\/code> (NX-OS) or <code>show platform software fed switch active stp vlan &lt;vlan-id&gt;<\/code> (Catalyst 9000 IOS-XE) to confirm that the hardware ASIC port forwarding state matches the software control-plane STP state.<\/li>\n<li><strong>Control Plane CPU Packet Capture:<\/strong><br \/>\n   <em>On Catalyst 9000 Series (IOS-XE), capture in-band packets punted to the CPU to identify the exact frame header looping on the wire:<\/em><br \/>\n   <code>ios<br \/>\n   monitor capture TAC_CPU_CAP control-plane in match any buffer size 10<br \/>\n   monitor capture TAC_CPU_CAP start<br \/>\n   ! Wait 5-10 seconds during the loop event<br \/>\n   monitor capture TAC_CPU_CAP stop<br \/>\n   show monitor capture TAC_CPU_CAP buffer brief<\/code><\/li>\n<li><strong>Crashinfo and OBFL Logs:<\/strong><\/li>\n<li><code>show logging onboard switch active uptime<\/code> and <code>dir flash:core\/<\/code> to rule out supervisor switchovers caused by STP process starvation.<\/li>\n<\/ol>\n<p><strong>Key Takeaway:<\/strong> Verifying hardware ASIC forwarding states against control-plane STP states and capturing in-band CPU punted packets provides the exact evidence needed to resolve complex platform bugs with Cisco TAC.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Checking for a loop in a Cisco switch is fastest when approached methodically. Start by confirming the outbreak through <code>%SW_MATM-4-MACFLAP_NOTIF<\/code> syslog messages and CPU interrupt statistics, then trace the storm down the topology using STP topology change counters (<code>show spanning-tree detail<\/code>) and interface broadcast metrics (<code>show interfaces counters<\/code>). For elusive single-port loops caused by unmanaged desktop switches, compare ingress versus egress broadcast packet counters on access ports learning multiple MAC addresses. Finally, deploying BPDU Guard, Storm Control, Loop Guard, and Aggressive UDLD across your access and trunk layers ensures that future physical wiring mistakes are isolated automatically in milliseconds before they can impact your wider network.<\/p>\n<div class='sfsi_Sicons' style='width: 100%; display: inline-block; vertical-align: middle; text-align:left'><div style='margin:0px 8px 0px 0px; line-height: 24px'><span>Please follow and like us:<\/span><\/div><div class='sfsi_socialwpr'><div class='sf_fb_share sf_icon' style='text-align:left;vertical-align: middle;'><a href='https:\/\/www.facebook.com\/sharer\/sharer.php?u=https%3A%2F%2Fcciedump.spoto.net%2Fblog%2Fhow-to-check-loop-in-cisco-switch_24587.html' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Facebook Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/fbshare_bck.png'  \/><\/a><\/div><div class='sf_twiter sf_icon' style='display: inline-block;vertical-align: middle;width: auto;margin-left: 7px;'>\r\n\t\t\t\t\t\t<a target='_blank' href='https:\/\/twitter.com\/intent\/tweet?text=How+to+Check+Loop+in+Cisco+Switch+https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html'style='display:inline-block' >\r\n\t\t\t\t\t\t\t<img data-pin-nopin= true width='auto' class='sfsi_wicon' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/en_US_Tweet.svg' alt='Tweet' title='Tweet' >\r\n\t\t\t\t\t\t<\/a>\r\n\t\t\t\t\t<\/div><div class='sf_pinit sf_icon' style='text-align:left;vertical-align: middle;float:left;line-height: 33px;width:auto;margin: 0 -2px;'><a href='#'  onclick='sfsi_pinterest_modal_images(event,\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\",\"How to Check Loop in Cisco Switch\")' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Pin Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/share_icons\/Pinterest_Save\/en_US_save.svg'  \/><\/a><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>A Layer 2 switching loop is one of the most disruptive failures a network administrator can face. Because Ethernet frames lack a Time-to-Live (TTL) header field, broadcast, multicast, and unknown unicast frames caught in a physical or logical loop circulate endlessly at line rate. Within seconds, a single miswired patch cable or malfunctioning downstream switch&#8230; &raquo; <a class=\"read-more-link\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\">read more<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,608],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Check Loop in Cisco Switch - SPOTO Official Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Check Loop in Cisco Switch - SPOTO Official Blog\" \/>\n<meta property=\"og:description\" content=\"A Layer 2 switching loop is one of the most disruptive failures a network administrator can face. Because Ethernet frames lack a Time-to-Live (TTL) header field, broadcast, multicast, and unknown unicast frames caught in a physical or logical loop circulate endlessly at line rate. Within seconds, a single miswired patch cable or malfunctioning downstream switch... &raquo; read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\" \/>\n<meta property=\"og:site_name\" content=\"SPOTO Official Blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T07:48:13+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"SPOTO \u7f16\u8f91\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\",\"name\":\"SPOTO Club\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"caption\":\"SPOTO Club\"},\"logo\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\"},\"description\":\"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205\",\"sameAs\":[\"https:\/\/cciedump.spoto.net\/\"]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/\",\"name\":\"SPOTO Official Blog\",\"description\":\"Focus on Online IT Training for 20+ Years\",\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#webpage\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\",\"name\":\"How to Check Loop in Cisco Switch - SPOTO Official Blog\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\"},\"datePublished\":\"2026-11-17T07:48:13+00:00\",\"dateModified\":\"2026-11-17T07:48:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cciedump.spoto.net\/blog\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Check Loop in Cisco Switch\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#article\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#webpage\"},\"author\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\"},\"headline\":\"How to Check Loop in Cisco Switch\",\"datePublished\":\"2026-11-17T07:48:13+00:00\",\"dateModified\":\"2026-11-17T07:48:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#webpage\"},\"wordCount\":2208,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"articleSection\":[\"CCNA Certification\",\"Cisco Certification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\",\"name\":\"SPOTO \u7f16\u8f91\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"caption\":\"SPOTO \u7f16\u8f91\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Check Loop in Cisco Switch - SPOTO Official Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html","og_locale":"en_US","og_type":"article","og_title":"How to Check Loop in Cisco Switch - SPOTO Official Blog","og_description":"A Layer 2 switching loop is one of the most disruptive failures a network administrator can face. Because Ethernet frames lack a Time-to-Live (TTL) header field, broadcast, multicast, and unknown unicast frames caught in a physical or logical loop circulate endlessly at line rate. Within seconds, a single miswired patch cable or malfunctioning downstream switch... &raquo; read more","og_url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html","og_site_name":"SPOTO Official Blog","article_published_time":"2026-11-17T07:48:13+00:00","twitter_card":"summary_large_image","twitter_misc":{"Written by":"SPOTO \u7f16\u8f91","Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Person","Organization"],"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638","name":"SPOTO Club","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","caption":"SPOTO Club"},"logo":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo"},"description":"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205","sameAs":["https:\/\/cciedump.spoto.net\/"]},{"@type":"WebSite","@id":"https:\/\/cciedump.spoto.net\/blog\/#website","url":"https:\/\/cciedump.spoto.net\/blog\/","name":"SPOTO Official Blog","description":"Focus on Online IT Training for 20+ Years","publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#webpage","url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html","name":"How to Check Loop in Cisco Switch - SPOTO Official Blog","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#website"},"datePublished":"2026-11-17T07:48:13+00:00","dateModified":"2026-11-17T07:48:13+00:00","breadcrumb":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cciedump.spoto.net\/blog"},{"@type":"ListItem","position":2,"name":"How to Check Loop in Cisco Switch"}]},{"@type":"Article","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#article","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#webpage"},"author":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1"},"headline":"How to Check Loop in Cisco Switch","datePublished":"2026-11-17T07:48:13+00:00","dateModified":"2026-11-17T07:48:13+00:00","mainEntityOfPage":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#webpage"},"wordCount":2208,"commentCount":0,"publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"articleSection":["CCNA Certification","Cisco Certification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-loop-in-cisco-switch_24587.html#respond"]}]},{"@type":"Person","@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1","name":"SPOTO \u7f16\u8f91","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","caption":"SPOTO \u7f16\u8f91"}}]}},"_links":{"self":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24587"}],"collection":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/comments?post=24587"}],"version-history":[{"count":0,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24587\/revisions"}],"wp:attachment":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/media?parent=24587"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/categories?post=24587"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/tags?post=24587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}