{"id":24578,"date":"2026-11-17T15:13:38","date_gmt":"2026-11-17T07:13:38","guid":{"rendered":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html"},"modified":"2026-11-17T15:13:38","modified_gmt":"2026-11-17T07:13:38","slug":"how-to-check-flash-memory-in-cisco-switch","status":"publish","type":"post","link":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html","title":{"rendered":"How to Check Flash Memory in Cisco Switch"},"content":{"rendered":"<p>Verifying available flash memory on a Cisco switch is a mandatory check before staging firmware upgrades, storing packet captures, or troubleshooting unexpected system reloads. Because flash storage holds the operating system image, boot configuration packages, and diagnostic crash logs, running out of space can cause software installations to fail mid-deployment. Understanding how to inspect storage metrics across standalone switches, multi-switch stacks, and enterprise monitoring platforms ensures your network hardware remains ready for maintenance.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_17 counter-hierarchy counter-decimal ez-toc-light-blue\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" style=\"display: none;\"><i class=\"ez-toc-glyphicon ez-toc-icon-toggle\"><\/i><\/a><\/span><\/div>\n<nav><ul class=\"ez-toc-list ez-toc-list-level-1\"><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#Step-by-Step_Guide_to_Checking_Flash_Memory_via_the_Cisco_CLI\" title=\"Step-by-Step Guide to Checking Flash Memory via the Cisco CLI\">Step-by-Step Guide to Checking Flash Memory via the Cisco CLI<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#Comparing_show_flash_dir_flash_and_show_file_systems\" title=\"Comparing show flash:, dir flash:, and show file systems\">Comparing show flash:, dir flash:, and show file systems<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#Interpreting_Output_Metrics_Across_Cisco_File_System_Classes\" title=\"Interpreting Output Metrics Across Cisco File System Classes\">Interpreting Output Metrics Across Cisco File System Classes<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#CLI_Templates_for_Switch_Stacks_Redundant_Supervisors_and_NX-OS\" title=\"CLI Templates for Switch Stacks, Redundant Supervisors, and NX-OS\">CLI Templates for Switch Stacks, Redundant Supervisors, and NX-OS<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#How_to_Free_Up_Flash_Memory_Before_an_IOS_Upgrade\" title=\"How to Free Up Flash Memory Before an IOS Upgrade\">How to Free Up Flash Memory Before an IOS Upgrade<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#SNMP_OIDs_and_Network_Management_Tools_for_Fleet-Wide_Flash_Auditing\" title=\"SNMP OIDs and Network Management Tools for Fleet-Wide Flash Auditing\">SNMP OIDs and Network Management Tools for Fleet-Wide Flash Auditing<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#Cisco_File_System_Command_Reference_and_Official_Documentation_Index\" title=\"Cisco File System Command Reference and Official Documentation Index\">Cisco File System Command Reference and Official Documentation Index<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#Formal_Command_Syntax_Specifications\" title=\"Formal Command Syntax Specifications\">Formal Command Syntax Specifications<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\/#Official_Cisco_Documentation_Publications_by_OS_Train\" title=\"Official Cisco Documentation Publications by OS Train\">Official Cisco Documentation Publications by OS Train<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Step-by-Step_Guide_to_Checking_Flash_Memory_via_the_Cisco_CLI\"><\/span>Step-by-Step Guide to Checking Flash Memory via the Cisco CLI<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Checking the total, used, and remaining storage capacity on a Cisco switch requires only a few commands in the command-line interface (CLI). Follow this sequential progression to inspect your primary flash partition and calculate available space.<\/p>\n<ol>\n<li>\n<p><strong>Access Privileged EXEC Mode<\/strong><br \/>\n   Connect to the switch via SSH or console and elevate your session to Privileged EXEC mode. While basic directory views work in User EXEC mode (<code>Switch&gt;<\/code>), full file system diagnostics require elevated privileges:<br \/>\n   <code>ios<br \/>\n   Switch&gt; enable<br \/>\n   Switch#<\/code><\/p>\n<\/li>\n<li>\n<p><strong>Execute the Primary Flash Inspection Command<\/strong><br \/>\n   Run <code>show flash:<\/code> (or <code>dir flash:<\/code>) to list all files stored in the default flash partition alongside the storage summary:<br \/>\n   &#8220;`ios<br \/>\n   Switch# show flash:<\/p>\n<\/li>\n<\/ol>\n<p>Directory of flash:\/<\/p>\n<pre><code>   1  -rw-        4096  Nov 10 2026 08:14:22 +00:00  vlan.dat\n   2  -rw-        2097  Nov 12 2026 14:02:11 +00:00  multiple-fs\n   3  -rw-   489214592  Oct 04 2026 09:30:00 +00:00  cat9k_lite_iosxe.17.09.04a.SPA.bin\n   4  -rw-        1245  Oct 04 2026 09:34:18 +00:00  packages.conf\n<\/code><\/pre>\n<p>11353194496 bytes total (6421843968 bytes free)<br \/>\n   &#8220;`<\/p>\n<ol>\n<li><strong>Read the Capacity Summary Footer<\/strong><br \/>\n   Locate the final line of the command output, which reports two critical numbers in bytes:<\/li>\n<li><strong><code>bytes total<\/code><\/strong>: The overall formatted capacity of the flash partition (<code>11,353,194,496 bytes<\/code>, or approximately 11.35 GB).<\/li>\n<li><strong><code>bytes free<\/code><\/strong>: The unallocated space currently available for new files (<code>6,421,843,968 bytes<\/code>, or approximately 6.42 GB).<\/li>\n<li>\n<p><strong>Used Space Calculation<\/strong>: Subtract <code>bytes free<\/code> from <code>bytes total<\/code> to determine consumed storage, or inspect individual file sizes in the fourth column of the directory listing.<\/p>\n<\/li>\n<li>\n<p><strong>Filter Output for Quick Capacity Audits<\/strong><br \/>\n   When a switch contains dozens of unpacked <code>.pkg<\/code> files or diagnostic logs, bypass the file list by piping the command output to <code>include bytes<\/code>:<br \/>\n   <code>ios<br \/>\n   Switch# show flash: | include bytes<br \/>\n   11353194496 bytes total (6421843968 bytes free)<\/code><\/p>\n<\/li>\n<li>\n<p><strong>Convert Bytes to Megabytes or Gigabytes<\/strong><br \/>\n   Cisco IOS and IOS-XE always report flash storage in raw bytes. For quick capacity planning before transferring a new image, divide the <code>bytes free<\/code> value by <code>1,048,576<\/code> ($1024^2$) to get Megabytes (MiB), or move the decimal point nine places to the left for a quick Gigabyte (GB) estimate.<\/p>\n<\/li>\n<\/ol>\n<p><strong>Key Takeaway:<\/strong> Always inspect the bottom summary line of <code>show flash:<\/code> and convert the raw byte count into gigabytes to verify that your available space exceeds the size of any incoming firmware file plus extraction overhead.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Comparing_show_flash_dir_flash_and_show_file_systems\"><\/span>Comparing <code>show flash:<\/code>, <code>dir flash:<\/code>, and <code>show file systems<\/code><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>While the basic inspection steps above reveal free space on the primary partition, Cisco IOS provides several distinct file system commands that expose different metadata. Choosing the right command helps you distinguish between a single directory&#8217;s contents and the switch&#8217;s entire storage architecture.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Comparison Criteria<\/th>\n<th style=\"text-align: left;\"><code>show flash:<\/code><\/th>\n<th style=\"text-align: left;\"><code>dir flash:<\/code><\/th>\n<th style=\"text-align: left;\"><code>show file systems<\/code><\/th>\n<th style=\"text-align: left;\"><code>dir \/all flash:<\/code><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Primary Purpose<\/strong><\/td>\n<td style=\"text-align: left;\">Displays layout and contents of the flash memory device<\/td>\n<td style=\"text-align: left;\">Lists files and subdirectories within a specified directory path<\/td>\n<td style=\"text-align: left;\">Summarizes all mounted storage media and partitions on the switch<\/td>\n<td style=\"text-align: left;\">Lists all visible, hidden, and undeleted files in flash<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Scope of Output<\/strong><\/td>\n<td style=\"text-align: left;\">Default flash partition only<\/td>\n<td style=\"text-align: left;\">Specified directory or default working directory (<code>pwd<\/code>)<\/td>\n<td style=\"text-align: left;\">All partitions (<code>flash:<\/code>, <code>nvram:<\/code>, <code>usbflash0:<\/code>, <code>crashinfo:<\/code>, stack members)<\/td>\n<td style=\"text-align: left;\">Target partition including system-hidden files<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Capacity Metrics Shown<\/strong><\/td>\n<td style=\"text-align: left;\">Total bytes, free bytes, and per-file byte size<\/td>\n<td style=\"text-align: left;\">Total bytes, free bytes, and per-file byte size<\/td>\n<td style=\"text-align: left;\">Total <code>Size(b)<\/code> and <code>Free(b)<\/code> side-by-side per mount point<\/td>\n<td style=\"text-align: left;\">Total bytes, free bytes, and space held by deleted files<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Hardware Metadata<\/strong><\/td>\n<td style=\"text-align: left;\">Shows chip\/sector geometry on legacy Class A\/B flash<\/td>\n<td style=\"text-align: left;\">Standard POSIX-style permissions (<code>-rw-<\/code>, <code>drwx<\/code>) and timestamps<\/td>\n<td style=\"text-align: left;\">File system type (<code>disk<\/code>, <code>nvram<\/code>, <code>opaque<\/code>) and access flags (<code>rw<\/code>, <code>ro<\/code>)<\/td>\n<td style=\"text-align: left;\">Standard permissions plus <code>[deleted]<\/code> file markers on legacy flash<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Default Alias<\/strong><\/td>\n<td style=\"text-align: left;\">Fixed to <code>flash:<\/code> unless a specific device is appended<\/td>\n<td style=\"text-align: left;\">Uses current working directory if <code>flash:<\/code> is omitted<\/td>\n<td style=\"text-align: left;\">Displays an asterisk (<code>*<\/code>) next to the current default file system<\/td>\n<td style=\"text-align: left;\">Requires explicit target or defaults to working directory<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Best Use Case<\/strong><\/td>\n<td style=\"text-align: left;\">Quick check of main flash contents and available space<\/td>\n<td style=\"text-align: left;\">Navigating subdirectories (such as <code>flash:\/dc_profile_dir\/<\/code>)<\/td>\n<td style=\"text-align: left;\">Auditing all storage volumes and stack member flash names at once<\/td>\n<td style=\"text-align: left;\">Identifying hidden files or unrecovered space on older switches<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span class=\"ez-toc-section\" id=\"Interpreting_Output_Metrics_Across_Cisco_File_System_Classes\"><\/span>Interpreting Output Metrics Across Cisco File System Classes<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>When reading the <code>Size<\/code> and <code>Free<\/code> metrics across these commands, how the switch calculates free space depends on its underlying file system class:<\/p>\n<ul>\n<li><strong>Class C File Systems (Modern Catalyst 2960-X, 3650, 3850, and 9000 Series):<\/strong> Uses standard disk-style allocation (<code>disk<\/code> type in <code>show file systems<\/code>). Deleting a file immediately increases the <code>bytes free<\/code> counter, and <code>show flash:<\/code> produces identical output to <code>dir flash:<\/code>.<\/li>\n<li><strong>Class A and B File Systems (Legacy IOS Devices):<\/strong> Found on older linear flash architectures. Deleted files are marked as deleted rather than erased immediately, meaning <code>bytes total<\/code> minus visible files will not equal <code>bytes free<\/code> until the partition is erased or squeezed.<\/li>\n<li><strong><code>show file systems<\/code> Flags:<\/strong> In the output of <code>show file systems<\/code>, verify that your target flash partition displays <code>rw<\/code> (read\/write) under the <code>Flags<\/code> column. A <code>ro<\/code> (read-only) flag indicates file system corruption or hardware write protection requiring a reboot or maintenance check.<\/li>\n<\/ul>\n<p><strong>Key Takeaway:<\/strong> Use <code>show file systems<\/code> when you need a high-level capacity overview of every storage volume on the chassis, and use <code>dir flash:<\/code> when navigating specific subdirectories.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"CLI_Templates_for_Switch_Stacks_Redundant_Supervisors_and_NX-OS\"><\/span>CLI Templates for Switch Stacks, Redundant Supervisors, and NX-OS<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>In enterprise deployments, inspecting the active supervisor or stack master is only half the job\u2014every member switch in a stack and every standby supervisor engine maintains its own independent flash partition. Use the following CLI templates to check flash storage across multi-unit and multi-OS environments.<\/p>\n<pre><code class=\"language-ios\">! =====================================================================\n! 1. CISCO CATALYST STACKWISE (IOS \/ IOS-XE: Catalyst 9200, 9300, 3850)\n! =====================================================================\n! List all mounted stack member flash prefixes (e.g., flash-1:, flash-2:)\nSwitch# show file systems | include flash\n\n! Check flash space on a specific stack member (replace &lt;member-id&gt; with 1-9)\nSwitch# dir flash-&lt;member-id&gt;: | include bytes\n\n! Alternative syntax supported on older Catalyst stacks (2960-X \/ 3750-X)\nSwitch# show flash&lt;member-id&gt;:\n\n! =====================================================================\n! 2. MODULAR DUAL-SUPERVISOR SWITCHES (Catalyst 9400, 9600, 6500, 4500)\n! =====================================================================\n! Check Active Supervisor flash storage\nSwitch# dir bootflash: | include bytes\n\n! Check Standby Supervisor flash storage on IOS-XE (Catalyst 9400\/9600)\nSwitch# dir stby-bootflash: | include bytes\n\n! Check Standby Supervisor flash storage on Classic IOS (Catalyst 4500\/6500)\nSwitch# dir slavebootflash: | include bytes\n\n!Check USB flash drive inserted into Active Supervisor\nSwitch# dir usbflash0: | include bytes\n<\/code><\/pre>\n<pre><code class=\"language-nxos\">! =====================================================================\n! 3. CISCO NEXUS SWITCHES (NX-OS: Nexus 9000, 7000, 3000 Series)\n! =====================================================================\n! Check primary bootflash directory and usage summary (Active Supervisor)\nswitch# dir bootflash: | include bytes\n\n! Check Standby Supervisor bootflash on dual-supervisor Nexus chassis\nswitch# dir bootflash:\/\/sup-standby\/ | include bytes\n\n! Inspect all internal Linux-backed flash partitions (\/bootflash, \/nxos\/tmp)\nswitch# show system internal flash\n<\/code><\/pre>\n<p><strong>Key Takeaway:<\/strong> Always verify available flash space on every stack member (<code>flash-1:<\/code>, <code>flash-2:<\/code>, etc.) and standby supervisor (<code>stby-bootflash:<\/code>) before an upgrade, as a single full member will cause a cluster-wide installation to abort.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Free_Up_Flash_Memory_Before_an_IOS_Upgrade\"><\/span>How to Free Up Flash Memory Before an IOS Upgrade<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>If your inspection reveals that free flash memory is below the 1 GB to 1.5 GB threshold required to expand modern Cisco IOS-XE images, you must safely clean the file system before transferring new firmware. Follow this sequential procedure to reclaim space without deleting active boot files.<\/p>\n<ol>\n<li><strong>Verify the Currently Running Image and Boot Mode<\/strong><br \/>\n   Before deleting any files, confirm which image or package configuration file the switch is actively using so you do not render the device unbootable:<br \/>\n   <code>ios<br \/>\n   Switch# show version | include System image|Installation mode<br \/>\n   System image file is \"flash:packages.conf\"<br \/>\n   Installation mode is INSTALL<\/code><\/li>\n<li>If the system image is <code>flash:packages.conf<\/code>, the switch is running in <strong>Install Mode<\/strong> (standard for Catalyst 9000 series).<\/li>\n<li>\n<p>If the system image ends in <code>.bin<\/code>, the switch is running in <strong>Bundle Mode<\/strong> (common on classic IOS and older Catalyst platforms).<\/p>\n<\/li>\n<li>\n<p><strong>Remove Inactive Packages Automatedly (Install Mode Only)<\/strong><br \/>\n   On Catalyst switches running IOS-XE in Install Mode, never manually delete <code>.pkg<\/code> files. Instead, run the built-in package cleanup command, which scans <code>packages.conf<\/code> across all stack members and automatically purges uncommitted <code>.pkg<\/code> files and leftover <code>.bin<\/code> archives:<br \/>\n   &#8220;`ios<br \/>\n   ! For Cisco IOS-XE 16.10.1 and all 17.x releases:<br \/>\n   Switch# install remove inactive<\/p>\n<\/li>\n<\/ol>\n<p>! For older Cisco IOS-XE 16.x releases (16.1.x to 16.9.x):<br \/>\n   Switch# request platform software package clean switch all file flash:<br \/>\n   <code>``<br \/>\n   Review the list of candidate files displayed by the prompt and type<\/code>y` to confirm deletion.<\/p>\n<ol>\n<li><strong>Delete Obsolete <code>.bin<\/code> Images and Archives Manually (Bundle Mode &amp; General Cleanup)<\/strong><br \/>\n   If the switch operates in Bundle Mode, or if orphan <code>.bin<\/code> and <code>.tar<\/code> files remain in flash, remove them manually using the <code>\/force<\/code> flag to skip confirmation prompts and <code>\/recursive<\/code> for old web UI directories:<br \/>\n   &#8220;`ios<br \/>\n   ! Delete a single obsolete .bin image file<br \/>\n   Switch# delete \/force flash:c2960x-universalk9-mz.152-4.E7.bin<\/li>\n<\/ol>\n<p>! Delete an old extracted HTML directory tree<br \/>\n   Switch# delete \/force \/recursive flash:c2960x-universalk9-mz.152-4.E7<br \/>\n   <code>``<br \/>\n   *Warning:* Never delete<\/code>packages.conf<code>,<\/code>vlan.dat<code>,<\/code>multiple-fs<code>, or any<\/code>.pkg` file referenced by your active boot variable.<\/p>\n<ol>\n<li>\n<p><strong>Clear Old Crashinfo Logs and Packet Captures<\/strong><br \/>\n   Diagnostic core dumps (<code>core_<\/code>), crash logs, and forgotten Embedded Packet Capture (<code>.pcap<\/code>) files frequently consume hundreds of megabytes. List and remove outdated diagnostic files:<br \/>\n   <code>ios<br \/>\n   Switch# dir flash:*.pcap<br \/>\n   Switch# delete \/force flash:troubleshooting_capture.pcap<br \/>\n   Switch# delete \/force crashinfo:crashinfo_20250814-021501-UTC<\/code><\/p>\n<\/li>\n<li>\n<p><strong>Reclaim Deleted Space on Legacy Flash (<code>squeeze<\/code>)<\/strong><br \/>\n   If you are maintaining a legacy Class A or Class B flash device where deleting files did not increase the <code>bytes free<\/code> counter, run <code>squeeze flash:<\/code> to permanently purge <code>[deleted]<\/code> blocks and defragment free space. Finally, re-run the capacity check covered in the first section to confirm you have met your upgrade storage target.<\/p>\n<\/li>\n<\/ol>\n<p><strong>Key Takeaway:<\/strong> Always use <code>install remove inactive<\/code> to clean up IOS-XE Install Mode switches rather than manually deleting <code>.pkg<\/code> files, and verify active boot files with <code>show version<\/code> before removing any <code>.bin<\/code> image.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"SNMP_OIDs_and_Network_Management_Tools_for_Fleet-Wide_Flash_Auditing\"><\/span>SNMP OIDs and Network Management Tools for Fleet-Wide Flash Auditing<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Logging into switches one by one via CLI is impractical when preparing hundreds of access switches for a network-wide code upgrade. Network administrators can automate flash storage audits at scale using SNMP MIB polling, orchestration tools, and commercial monitoring suites:<\/p>\n<ol>\n<li><strong>Standard 32-Bit SNMP Polling (<code>CISCO-FLASH-MIB<\/code>)<\/strong><br \/>\n   For switches with flash partitions smaller than 4.29 GB, poll the <code>ciscoFlashPartitionTable<\/code> using standard 32-bit <code>Gauge32<\/code> objects:<\/li>\n<li><strong>Total Partition Size (<code>ciscoFlashPartitionSize<\/code>):<\/strong> <code>1.3.6.1.4.1.9.9.10.1.1.4.1.1.4<\/code> (returns size in bytes).<\/li>\n<li>\n<p><strong>Available Free Space (<code>ciscoFlashPartitionFreeSpace<\/code>):<\/strong> <code>1.3.6.1.4.1.9.9.10.1.1.4.1.1.5<\/code> (returns largest single file size in bytes that can be copied in).<\/p>\n<\/li>\n<li>\n<p><strong>64-Bit Extended SNMP OIDs for Catalyst 9000 Series<\/strong><br \/>\n   Modern Cisco switches carry 8 GB to 16 GB+ of internal flash, which exceeds the 32-bit SNMP integer ceiling (<code>4,294,967,295<\/code> bytes). When polling Catalyst 9200, 9300, 9400, or 9500 switches, configure your NMS to query the 64-bit <code>CounterBasedGauge64<\/code> objects:<\/p>\n<\/li>\n<li><strong>Extended Partition Size (<code>ciscoFlashPartitionSizeExtended<\/code>):<\/strong> <code>1.3.6.1.4.1.9.9.10.1.1.4.1.1.13<\/code><\/li>\n<li>\n<p><strong>Extended Free Space (<code>ciscoFlashPartitionFreeSpaceExtended<\/code>):<\/strong> <code>1.3.6.1.4.1.9.9.10.1.1.4.1.1.14<\/code><\/p>\n<\/li>\n<li>\n<p><strong>Proactive Low-Space SNMP Trap Thresholds<\/strong><br \/>\n   Instead of relying solely on periodic polling, you can monitor <code>ciscoFlashPartitionLowSpaceNotifThreshold<\/code> (<code>1.3.6.1.4.1.9.9.10.1.1.4.1.1.15<\/code>), which defines the minimum percentage of free space on a partition before the switch generates a <code>ciscoFlashPartitionLowSpaceNotif<\/code> SNMP trap.<\/p>\n<\/li>\n<li>\n<p><strong>Cisco Catalyst Center (Formerly Cisco DNA Center)<\/strong><br \/>\n   Cisco Catalyst Center includes a dedicated Software Image Management (SWIM) engine that automatically audits flash space across your entire switch inventory during the Pre-Upgrade Check phase. If a switch lacks sufficient flash capacity, Catalyst Center can automatically trigger <code>install remove inactive<\/code> before distributing the golden image.<\/p>\n<\/li>\n<li>\n<p><strong>Enterprise Network Monitoring Platforms (SolarWinds, PRTG, LibreNMS, Observium)<\/strong><br \/>\n   Platforms such as Observium, LibreNMS, SolarWinds Network Performance Monitor (NPM), and Paessler PRTG natively ingest <code>CISCO-FLASH-MIB<\/code> during device discovery. These tools graph historical flash utilization and trigger alerts when a sudden storage spike\u2014such as an automated core dump or runaway debug log\u2014threatens to fill the partition.<\/p>\n<\/li>\n<li>\n<p><strong>Ansible (<code>cisco.ios.ios_facts<\/code>) and Python Automation<\/strong><br \/>\n   For on-demand pre-upgrade checks without SNMP, run an Ansible playbook utilizing the <code>cisco.ios.ios_facts<\/code> module (with <code>gather_subset: hardware<\/code>). Ansible populates the <code>ansible_net_filesystems_info<\/code> dictionary with exact <code>spacetotal_kb<\/code> and <code>spacefree_kb<\/code> values for every mounted flash volume, allowing playbooks to conditionally skip or clean switches that fall below your threshold.<\/p>\n<\/li>\n<\/ol>\n<p><strong>Key Takeaway:<\/strong> When monitoring modern Catalyst 9000 switches via SNMP, always poll the 64-bit <code>ciscoFlashPartitionFreeSpaceExtended<\/code> OID (<code>1.3.6.1.4.1.9.9.10.1.1.4.1.1.14<\/code>) so partitions larger than 4.29 GB are not truncated.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Cisco_File_System_Command_Reference_and_Official_Documentation_Index\"><\/span>Cisco File System Command Reference and Official Documentation Index<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>This section provides the formal command syntax specifications and the official Cisco documentation structure for file system management across Cisco operating systems.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Formal_Command_Syntax_Specifications\"><\/span>Formal Command Syntax Specifications<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong><code>show [filesystem:]<\/code><\/strong><\/li>\n<li><em>Description:<\/em> Displays the physical layout, file directory, and byte capacity summary of a specified flash memory file system.<\/li>\n<li><em>Command Mode:<\/em> User EXEC (<code>&gt;<\/code>) or Privileged EXEC (<code>#<\/code>).<\/li>\n<li>\n<p><em>Syntax Arguments:<\/em> <code>filesystem:<\/code> (Optional) \u2014 Specifies the flash memory device prefix followed by a colon (for example, <code>flash:<\/code>, <code>bootflash:<\/code>, <code>slot0:<\/code>, <code>stby-bootflash:<\/code>). Defaults to <code>flash:<\/code> when omitted.<\/p>\n<\/li>\n<li>\n<p><strong><code>dir [\/all | \/recursive] [filesystem:[directory | filename]]<\/code><\/strong><\/p>\n<\/li>\n<li><em>Description:<\/em> Displays a list of files and subdirectories on a file system.<\/li>\n<li><em>Command Mode:<\/em> User EXEC (<code>&gt;<\/code>) or Privileged EXEC (<code>#<\/code>).<\/li>\n<li>\n<p><em>Syntax Arguments:<\/em><\/p>\n<ul>\n<li><code>\/all<\/code> (Optional) \u2014 Lists all files, including deleted and system-hidden files.<\/li>\n<li><code>\/recursive<\/code> (Optional) \u2014 Lists files across all subdirectories dynamically.<\/li>\n<li><code>filesystem:<\/code> (Optional) \u2014 Target storage prefix followed by a colon. If omitted, uses the working directory defined by the <code>cd<\/code> command (<code>pwd<\/code>).<\/li>\n<\/ul>\n<\/li>\n<li>\n<p><strong><code>show file systems<\/code><\/strong><\/p>\n<\/li>\n<li><em>Description:<\/em> Lists all available file systems registered on the switch, including their byte size, free byte capacity, media type, access permissions, and alias prefix names.<\/li>\n<li><em>Command Mode:<\/em> Privileged EXEC (<code>#<\/code>).<\/li>\n<li><em>Syntax Arguments:<\/em> This command accepts no arguments or keywords.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Official_Cisco_Documentation_Publications_by_OS_Train\"><\/span>Official Cisco Documentation Publications by OS Train<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Operating System \/ Platform<\/th>\n<th style=\"text-align: left;\">Official Cisco Manual Title<\/th>\n<th style=\"text-align: left;\">Relevant Chapter \/ Command Section<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco IOS (Classic 12.2 \/ 15.x)<\/strong><\/td>\n<td style=\"text-align: left;\"><em>Cisco IOS Configuration Fundamentals Command Reference<\/em><\/td>\n<td style=\"text-align: left;\">&#8220;Cisco IOS File System Commands&#8221; (<code>show (flash file system)<\/code>, <code>show file systems<\/code>, <code>dir<\/code>, <code>delete<\/code>, <code>squeeze<\/code>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco IOS-XE (Catalyst 9000 Series, 16.x \/ 17.x)<\/strong><\/td>\n<td style=\"text-align: left;\"><em>Command Reference, Cisco IOS XE [Release] (Catalyst 9300 \/ 9200 \/ 9500 Switches)<\/em><\/td>\n<td style=\"text-align: left;\">&#8220;System Management Commands&#8221; (<code>install remove inactive<\/code>, <code>show file systems<\/code>, <code>dir<\/code>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco IOS-XE Configuration Guides<\/strong><\/td>\n<td style=\"text-align: left;\"><em>System Management Configuration Guide, Cisco IOS XE [Release]<\/em><\/td>\n<td style=\"text-align: left;\">&#8220;Managing Configuration Files&#8221; and &#8220;Performing Setup and Configuration&#8221;<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco NX-OS (Nexus 9000 \/ 7000 Series)<\/strong><\/td>\n<td style=\"text-align: left;\"><em>Cisco Nexus 9000 Series NX-OS Fundamentals Command Reference<\/em><\/td>\n<td style=\"text-align: left;\">&#8220;F Commands&#8221; and &#8220;D Commands&#8221; (<code>dir<\/code>, <code>show file<\/code>, <code>delete<\/code>, <code>show system internal flash<\/code>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Cisco SNMP MIB Specifications<\/strong><\/td>\n<td style=\"text-align: left;\"><em>Cisco SNMP Object Navigator \u2014 <code>CISCO-FLASH-MIB<\/code><\/em><\/td>\n<td style=\"text-align: left;\">OID Tree <code>1.3.6.1.4.1.9.9.10<\/code> (<code>ciscoFlashDevice<\/code> and <code>ciscoFlashPartitions<\/code>)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Key Takeaway:<\/strong> Consult the <em>System Management Command Reference<\/em> matching your specific IOS-XE or NX-OS release train whenever verifying platform-specific storage prefixes or package installation syntax.<\/p>\n<hr \/>\n<p>Maintaining visibility into your Cisco switch flash memory prevents failed upgrades and unexpected storage bottlenecks. By combining quick CLI inspections (<code>show flash:<\/code> and <code>show file systems<\/code>) with stack-wide checks, safe package cleanup via <code>install remove inactive<\/code>, and automated 64-bit SNMP monitoring, you can keep every switch in your network ready for seamless software maintenance.<\/p>\n<div class='sfsi_Sicons' style='width: 100%; display: inline-block; vertical-align: middle; text-align:left'><div style='margin:0px 8px 0px 0px; line-height: 24px'><span>Please follow and like us:<\/span><\/div><div class='sfsi_socialwpr'><div class='sf_fb_share sf_icon' style='text-align:left;vertical-align: middle;'><a href='https:\/\/www.facebook.com\/sharer\/sharer.php?u=https%3A%2F%2Fcciedump.spoto.net%2Fblog%2Fhow-to-check-flash-memory-in-cisco-switch_24578.html' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Facebook Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/fbshare_bck.png'  \/><\/a><\/div><div class='sf_twiter sf_icon' style='display: inline-block;vertical-align: middle;width: auto;margin-left: 7px;'>\r\n\t\t\t\t\t\t<a target='_blank' href='https:\/\/twitter.com\/intent\/tweet?text=How+to+Check+Flash+Memory+in+Cisco+Switch+https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html'style='display:inline-block' >\r\n\t\t\t\t\t\t\t<img data-pin-nopin= true width='auto' class='sfsi_wicon' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/en_US_Tweet.svg' alt='Tweet' title='Tweet' >\r\n\t\t\t\t\t\t<\/a>\r\n\t\t\t\t\t<\/div><div class='sf_pinit sf_icon' style='text-align:left;vertical-align: middle;float:left;line-height: 33px;width:auto;margin: 0 -2px;'><a href='#'  onclick='sfsi_pinterest_modal_images(event,\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\",\"How to Check Flash Memory in Cisco Switch\")' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Pin Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/share_icons\/Pinterest_Save\/en_US_save.svg'  \/><\/a><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Verifying available flash memory on a Cisco switch is a mandatory check before staging firmware upgrades, storing packet captures, or troubleshooting unexpected system reloads. Because flash storage holds the operating system image, boot configuration packages, and diagnostic crash logs, running out of space can cause software installations to fail mid-deployment. Understanding how to inspect storage&#8230; &raquo; <a class=\"read-more-link\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\">read more<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,608],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Check Flash Memory in Cisco Switch - SPOTO Official Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Check Flash Memory in Cisco Switch - SPOTO Official Blog\" \/>\n<meta property=\"og:description\" content=\"Verifying available flash memory on a Cisco switch is a mandatory check before staging firmware upgrades, storing packet captures, or troubleshooting unexpected system reloads. Because flash storage holds the operating system image, boot configuration packages, and diagnostic crash logs, running out of space can cause software installations to fail mid-deployment. Understanding how to inspect storage... &raquo; read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\" \/>\n<meta property=\"og:site_name\" content=\"SPOTO Official Blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T07:13:38+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"SPOTO \u7f16\u8f91\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\",\"name\":\"SPOTO Club\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"caption\":\"SPOTO Club\"},\"logo\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\"},\"description\":\"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205\",\"sameAs\":[\"https:\/\/cciedump.spoto.net\/\"]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/\",\"name\":\"SPOTO Official Blog\",\"description\":\"Focus on Online IT Training for 20+ Years\",\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#webpage\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\",\"name\":\"How to Check Flash Memory in Cisco Switch - SPOTO Official Blog\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\"},\"datePublished\":\"2026-11-17T07:13:38+00:00\",\"dateModified\":\"2026-11-17T07:13:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cciedump.spoto.net\/blog\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Check Flash Memory in Cisco Switch\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#article\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#webpage\"},\"author\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\"},\"headline\":\"How to Check Flash Memory in Cisco Switch\",\"datePublished\":\"2026-11-17T07:13:38+00:00\",\"dateModified\":\"2026-11-17T07:13:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#webpage\"},\"wordCount\":1928,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"articleSection\":[\"CCNA Certification\",\"Cisco Certification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\",\"name\":\"SPOTO \u7f16\u8f91\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"caption\":\"SPOTO \u7f16\u8f91\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Check Flash Memory in Cisco Switch - SPOTO Official Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html","og_locale":"en_US","og_type":"article","og_title":"How to Check Flash Memory in Cisco Switch - SPOTO Official Blog","og_description":"Verifying available flash memory on a Cisco switch is a mandatory check before staging firmware upgrades, storing packet captures, or troubleshooting unexpected system reloads. Because flash storage holds the operating system image, boot configuration packages, and diagnostic crash logs, running out of space can cause software installations to fail mid-deployment. Understanding how to inspect storage... &raquo; read more","og_url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html","og_site_name":"SPOTO Official Blog","article_published_time":"2026-11-17T07:13:38+00:00","twitter_card":"summary_large_image","twitter_misc":{"Written by":"SPOTO \u7f16\u8f91","Est. reading time":"12 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Person","Organization"],"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638","name":"SPOTO Club","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","caption":"SPOTO Club"},"logo":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo"},"description":"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205","sameAs":["https:\/\/cciedump.spoto.net\/"]},{"@type":"WebSite","@id":"https:\/\/cciedump.spoto.net\/blog\/#website","url":"https:\/\/cciedump.spoto.net\/blog\/","name":"SPOTO Official Blog","description":"Focus on Online IT Training for 20+ Years","publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#webpage","url":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html","name":"How to Check Flash Memory in Cisco Switch - SPOTO Official Blog","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#website"},"datePublished":"2026-11-17T07:13:38+00:00","dateModified":"2026-11-17T07:13:38+00:00","breadcrumb":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cciedump.spoto.net\/blog"},{"@type":"ListItem","position":2,"name":"How to Check Flash Memory in Cisco Switch"}]},{"@type":"Article","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#article","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#webpage"},"author":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1"},"headline":"How to Check Flash Memory in Cisco Switch","datePublished":"2026-11-17T07:13:38+00:00","dateModified":"2026-11-17T07:13:38+00:00","mainEntityOfPage":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#webpage"},"wordCount":1928,"commentCount":0,"publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"articleSection":["CCNA Certification","Cisco Certification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-check-flash-memory-in-cisco-switch_24578.html#respond"]}]},{"@type":"Person","@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1","name":"SPOTO \u7f16\u8f91","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","caption":"SPOTO \u7f16\u8f91"}}]}},"_links":{"self":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24578"}],"collection":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/comments?post=24578"}],"version-history":[{"count":0,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24578\/revisions"}],"wp:attachment":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/media?parent=24578"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/categories?post=24578"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/tags?post=24578"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}