{"id":24506,"date":"2026-11-16T11:26:31","date_gmt":"2026-11-16T03:26:31","guid":{"rendered":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html"},"modified":"2026-11-16T11:26:31","modified_gmt":"2026-11-16T03:26:31","slug":"how-to-bounce-port-on-cisco-switch","status":"publish","type":"post","link":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html","title":{"rendered":"How to Bounce Port on Cisco Switch"},"content":{"rendered":"<p>In enterprise campus and data center networking, bouncing a switch port is one of the most fundamental operational tasks performed by network administrators. Whether restoring connectivity to a frozen IP camera, clearing stale MAC address entries after a patch cable swap, or re-initiating 802.1X port authentication for a stubborn workstation, cycling an interface resets the physical and data link states to resolve elusive Layer 1 and Layer 2 glitches. <\/p>\n<p>While the concept of cycling an interface is simple, doing so safely and efficiently requires understanding Cisco IOS CLI mechanics, avoiding remote lockouts when working over an uplink, isolating PoE power cycling, and troubleshooting interfaces that refuse to come back up. This comprehensive guide covers everything from the core command reference to automated recovery scripts and diagnostic workflows.<\/p>\n<hr \/>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_17 counter-hierarchy counter-decimal ez-toc-light-blue\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" style=\"display: none;\"><i class=\"ez-toc-glyphicon ez-toc-icon-toggle\"><\/i><\/a><\/span><\/div>\n<nav><ul class=\"ez-toc-list ez-toc-list-level-1\"><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Port_Bouncing_Fundamentals_Purpose_Mechanics_and_Side_Effects\" title=\"Port Bouncing Fundamentals: Purpose, Mechanics, and Side Effects\">Port Bouncing Fundamentals: Purpose, Mechanics, and Side Effects<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Frequently_Asked_Questions\" title=\"Frequently Asked Questions\">Frequently Asked Questions<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Cisco_IOS_Interface_Command_Reference_shutdown_and_no_shutdown\" title=\"Cisco IOS Interface Command Reference: shutdown and no shutdown\">Cisco IOS Interface Command Reference: shutdown and no shutdown<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Command_Definition_and_Syntax\" title=\"Command Definition and Syntax\">Command Definition and Syntax<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Operational_Parameters_and_Defaults\" title=\"Operational Parameters and Defaults\">Operational Parameters and Defaults<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step-by-Step_Guide_Bouncing_a_Switchport_via_CLI\" title=\"Step-by-Step Guide: Bouncing a Switchport via CLI\">Step-by-Step Guide: Bouncing a Switchport via CLI<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_1_Access_Privileged_EXEC_Mode\" title=\"Step 1: Access Privileged EXEC Mode\">Step 1: Access Privileged EXEC Mode<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_2_Enter_Global_Configuration_Mode\" title=\"Step 2: Enter Global Configuration Mode\">Step 2: Enter Global Configuration Mode<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_3_Select_the_Target_Interface_or_Interface_Range\" title=\"Step 3: Select the Target Interface or Interface Range\">Step 3: Select the Target Interface or Interface Range<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_4_Administratively_Disable_the_Port\" title=\"Step 4: Administratively Disable the Port\">Step 4: Administratively Disable the Port<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_5_Allow_Link-Down_Propagation\" title=\"Step 5: Allow Link-Down Propagation\">Step 5: Allow Link-Down Propagation<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_6_Administratively_Re-enable_the_Port\" title=\"Step 6: Administratively Re-enable the Port\">Step 6: Administratively Re-enable the Port<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_7_Verify_Interface_Operational_Status\" title=\"Step 7: Verify Interface Operational Status\">Step 7: Verify Interface Operational Status<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Template_Safely_Bouncing_Remote_Uplinks_Without_Lockout\" title=\"Template: Safely Bouncing Remote Uplinks Without Lockout\">Template: Safely Bouncing Remote Uplinks Without Lockout<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Production_EEM_Applet_Template\" title=\"Production EEM Applet Template\">Production EEM Applet Template<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Execution_Command\" title=\"Execution Command\">Execution Command<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Optional_Safety_Net_Reload_Timer_Safeguard\" title=\"Optional Safety Net: Reload Timer Safeguard\">Optional Safety Net: Reload Timer Safeguard<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step-by-Step_Guide_Power-Cycling_PoE_Devices_Without_Data_Link_Shutdown\" title=\"Step-by-Step Guide: Power-Cycling PoE Devices Without Data Link Shutdown\">Step-by-Step Guide: Power-Cycling PoE Devices Without Data Link Shutdown<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_1_Verify_Connected_PoE_Draw_and_Power_Mode\" title=\"Step 1: Verify Connected PoE Draw and Power Mode\">Step 1: Verify Connected PoE Draw and Power Mode<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_2_Enter_Interface_Configuration_Mode\" title=\"Step 2: Enter Interface Configuration Mode\">Step 2: Enter Interface Configuration Mode<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_3_Disable_Inline_Power_Delivery\" title=\"Step 3: Disable Inline Power Delivery\">Step 3: Disable Inline Power Delivery<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_4_Allow_Capacitor_Discharge\" title=\"Step 4: Allow Capacitor Discharge\">Step 4: Allow Capacitor Discharge<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_5_Restore_Automatic_Inline_Power_Detection\" title=\"Step 5: Restore Automatic Inline Power Detection\">Step 5: Restore Automatic Inline Power Detection<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_6_Validate_Operational_Restoration\" title=\"Step 6: Validate Operational Restoration\">Step 6: Validate Operational Restoration<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Troubleshooting_Guide_Resolving_Ports_Down_or_err-disabled_After_a_Bounce\" title=\"Troubleshooting Guide: Resolving Ports Down or err-disabled After a Bounce\">Troubleshooting Guide: Resolving Ports Down or err-disabled After a Bounce<\/a><ul class=\"ez-toc-list-level-3\"><li class=\"ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_1_Identify_the_Interface_Operational_State\" title=\"Step 1: Identify the Interface Operational State\">Step 1: Identify the Interface Operational State<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_2_Identify_the_Root_Cause_of_the_Error\" title=\"Step 2: Identify the Root Cause of the Error\">Step 2: Identify the Root Cause of the Error<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_3_Remediate_Common_Root_Causes\" title=\"Step 3: Remediate Common Root Causes\">Step 3: Remediate Common Root Causes<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_4_Clear_the_Err-Disabled_State_and_Re-enable\" title=\"Step 4: Clear the Err-Disabled State and Re-enable\">Step 4: Clear the Err-Disabled State and Re-enable<\/a><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-3\"><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Step_5_Configure_Automatic_Err-Disable_Recovery_Best_Practice\" title=\"Step 5: Configure Automatic Err-Disable Recovery (Best Practice)\">Step 5: Configure Automatic Err-Disable Recovery (Best Practice)<\/a><\/li><\/ul><\/li><li class=\"ez-toc-page-1 ez-toc-heading-level-2\"><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\/#Conclusion\" title=\"Conclusion\">Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Port_Bouncing_Fundamentals_Purpose_Mechanics_and_Side_Effects\"><\/span>Port Bouncing Fundamentals: Purpose, Mechanics, and Side Effects<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Before issuing commands on production hardware, it is critical to understand how an administrative port bounce interacts with network state tables and attached endpoints.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Frequently Asked Questions<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong>Q: What does &#8220;bouncing a port&#8221; mean in Cisco networking?<\/strong><br \/>\n<strong>A:<\/strong> Bouncing a port is the process of administratively disabling an interface and immediately re-enabling it. In Cisco IOS and Cisco IOS-XE, this is executed by issuing the <code>shutdown<\/code> command followed by <code>no shutdown<\/code>. This operation forces the physical link (PHY) down and brings it back up, simulating a physical cable disconnect and reconnect without requiring manual intervention in the wiring closet.<\/p>\n<p><strong>Q: What technical issues does bouncing a port solve?<\/strong><br \/>\n<strong>A:<\/strong> Cycling an interface addresses several transient network states:<br \/>\n* <strong>DHCP Lease Re-negotiation:<\/strong> Forces the client endpoint to detect a media disconnect, causing its operating system to release its previous IP and broadcast a new <code>DHCPDISCOVER<\/code>.<br \/>\n* <strong>802.1X and MAB Re-Authentication:<\/strong> Re-triggers Extensible Authentication Protocol over LAN (EAPoL) exchanges or MAC Authentication Bypass (MAB) with network access control servers like Cisco ISE.<br \/>\n* <strong>Flushing Dynamic CAM\/MAC Tables:<\/strong> Instantly purges stale hardware address associations tied to that specific port on the switch.<br \/>\n* <strong>Auto-Negotiation Reset:<\/strong> Re-initializes Ethernet speed and duplex negotiation if an interface becomes locked in a mismatch or half-duplex mode.<\/p>\n<p><strong>Q: What side effects occur during a port bounce?<\/strong><br \/>\n<strong>A:<\/strong> Dropping an interface introduces immediate operational side effects:<br \/>\n* <strong>Session Termination:<\/strong> All active TCP\/UDP connections, voice calls, and secure tunnels traversing the interface terminate immediately.<br \/>\n* <strong>Spanning Tree Protocol (STP) State Transitions:<\/strong> The port re-evaluates topology state. Unless configured with <code>spanning-tree portfast<\/code>, the interface cycles through the Listening and Learning states before reaching Forwarding, introducing a 30-second delay.<br \/>\n* <strong>Upstream Routing Adjacencies:<\/strong> If the port is configured as a routed interface (<code>no switchport<\/code>), neighbor adjacencies for protocols like OSPF, EIGRP, or BGP drop, initiating route recalculation.<\/p>\n<p>With the operational impact clear, let us examine the formal command structure defined by Cisco IOS.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Cisco_IOS_Interface_Command_Reference_shutdown_and_no_shutdown\"><\/span>Cisco IOS Interface Command Reference: <code>shutdown<\/code> and <code>no shutdown<\/code><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The administrative state of any physical, logical, or virtual interface within Cisco IOS and Cisco IOS-XE is controlled using the <code>shutdown<\/code> and <code>no shutdown<\/code> interface configuration commands.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Command_Definition_and_Syntax\"><\/span>Command Definition and Syntax<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Command<\/th>\n<th style=\"text-align: left;\">Command Mode<\/th>\n<th style=\"text-align: left;\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><code>shutdown<\/code><\/td>\n<td style=\"text-align: left;\">Interface configuration (<code>config-if<\/code>) or Interface range (<code>config-if-range<\/code>)<\/td>\n<td style=\"text-align: left;\">Administratively disables the interface, turning off signal transmission and dropping link carrier state.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><code>no shutdown<\/code><\/td>\n<td style=\"text-align: left;\">Interface configuration (<code>config-if<\/code>) or Interface range (<code>config-if-range<\/code>)<\/td>\n<td style=\"text-align: left;\">Administratively enables the interface, permitting physical carrier detection and data forwarding.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span class=\"ez-toc-section\" id=\"Operational_Parameters_and_Defaults\"><\/span>Operational Parameters and Defaults<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><strong>Default State:<\/strong> On Layer 2 Cisco Catalyst switches (such as the Catalyst 2960, 3850, 9200, and 9300 series), physical 10\/100\/1000\/10G Ethernet ports default to the enabled state (<code>no shutdown<\/code>). Conversely, routed interfaces, Switch Virtual Interfaces (SVIs\/VLAN interfaces), and loopback interfaces on certain platform images default to <code>shutdown<\/code> until explicitly activated.<\/li>\n<li><strong>Hardware Signaling:<\/strong> Issuing <code>shutdown<\/code> deactivates the physical Layer 1 transceiver or PHY circuitry on copper interfaces and disables laser transmission on optical SFP\/SFP+ transceivers.<\/li>\n<li><strong>Status Interpretation:<\/strong><\/li>\n<li>When <code>shutdown<\/code> is applied: <code>Line status<\/code> reports <strong>administratively down<\/strong>; <code>Line protocol<\/code> reports <strong>down<\/strong>.<\/li>\n<li>When <code>no shutdown<\/code> is applied without a physical cable: <code>Line status<\/code> reports <strong>down<\/strong>; <code>Line protocol<\/code> reports <strong>down<\/strong>.<\/li>\n<li>When <code>no shutdown<\/code> is applied with a valid physical link: <code>Line status<\/code> reports <strong>up<\/strong>; <code>Line protocol<\/code> reports <strong>up<\/strong>.<\/li>\n<\/ul>\n<p>Having established the baseline command reference, the following section covers the routine procedure for cycling client-facing access ports.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Step-by-Step_Guide_Bouncing_a_Switchport_via_CLI\"><\/span>Step-by-Step Guide: Bouncing a Switchport via CLI<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The standard administrative bounce is executed from the Cisco IOS command-line interface via console, SSH, or Telnet.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Access_Privileged_EXEC_Mode\"><\/span>Step 1: Access Privileged EXEC Mode<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Log in to the switch and elevate your privilege level:<\/p>\n<pre><code class=\"language-text\">Switch&gt; enable\nPassword: *********\nSwitch#\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Enter_Global_Configuration_Mode\"><\/span>Step 2: Enter Global Configuration Mode<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Open the configuration staging buffer:<\/p>\n<pre><code class=\"language-text\">Switch# configure terminal\nEnter configuration commands, one per line.  End with CNTL\/Z.\nSwitch(config)#\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Select_the_Target_Interface_or_Interface_Range\"><\/span>Step 3: Select the Target Interface or Interface Range<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Specify the exact physical interface you intend to bounce. You can select an individual port or a range of contiguous\/non-contiguous ports:<\/p>\n<pre><code class=\"language-text\">! For a single interface:\nSwitch(config)# interface GigabitEthernet1\/0\/15\n\n! For multiple interfaces simultaneously:\nSwitch(config)# interface range GigabitEthernet1\/0\/1 - 8, GigabitEthernet1\/0\/12\nSwitch(config-if-range)#\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_4_Administratively_Disable_the_Port\"><\/span>Step 4: Administratively Disable the Port<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Execute the <code>shutdown<\/code> command:<\/p>\n<pre><code class=\"language-text\">Switch(config-if)# shutdown\n<\/code><\/pre>\n<p><em>System confirmation logs will confirm the state transition:<\/em><\/p>\n<pre><code class=\"language-text\">%LINK-5-CHANGED: Interface GigabitEthernet1\/0\/15, changed state to administratively down\n%LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1\/0\/15, changed state to down\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_5_Allow_Link-Down_Propagation\"><\/span>Step 5: Allow Link-Down Propagation<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Wait 3 to 5 seconds. This brief pause ensures that the connected device&#8217;s Network Interface Card (NIC) registers the loss of carrier signal, clears local socket state, and tears down active network sessions cleanly.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_6_Administratively_Re-enable_the_Port\"><\/span>Step 6: Administratively Re-enable the Port<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Restore the interface to operational service:<\/p>\n<pre><code class=\"language-text\">Switch(config-if)# no shutdown\nSwitch(config-if)# end\n<\/code><\/pre>\n<p><em>The switch logs will reflect the physical carrier link restoration:<\/em><\/p>\n<pre><code class=\"language-text\">%LINK-3-UPDOWN: Interface GigabitEthernet1\/0\/15, changed state to up\n%LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1\/0\/15, changed state to up\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_7_Verify_Interface_Operational_Status\"><\/span>Step 7: Verify Interface Operational Status<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Confirm that the interface has negotiated properly and entered the forwarding state:<\/p>\n<pre><code class=\"language-text\">Switch# show interfaces GigabitEthernet1\/0\/15 status\n\nPort      Name               Status       Vlan       Duplex  Speed Type\nGi1\/0\/15  Workstation-A      connected    10         a-full  a-1000 10\/100\/1000BaseTX\n<\/code><\/pre>\n<p>While this step-by-step workflow works seamlessly for edge ports, issuing a manual <code>shutdown<\/code> on a remote uplink or management port will immediately disconnect your SSH session, stranding the switch in an unreachable state.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Template_Safely_Bouncing_Remote_Uplinks_Without_Lockout\"><\/span>Template: Safely Bouncing Remote Uplinks Without Lockout<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When managing a switch remotely over an IP network, bouncing the trunk port or management uplink over which your SSH session travels requires an atomic, automated process. Because an interactive <code>shutdown<\/code> kills the management session before <code>no shutdown<\/code> can be entered, you must execute both commands programmatically on the switch CPU.<\/p>\n<p>Use the following Cisco IOS Embedded Event Manager (EEM) template to safely bounce remote interfaces without the risk of an unrecoverable lockout.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Production_EEM_Applet_Template\"><\/span>Production EEM Applet Template<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<pre><code class=\"language-cisco\">! =========================================================================\n! TEMPLATE: Automated Remote Port Bounce via Cisco IOS EEM\n! Description: Disables and re-enables an interface locally on the switch.\n! Usage: Replace &lt;INTERFACE_NAME&gt; with the target port (e.g., Gi1\/0\/48).\n! =========================================================================\n\nconfigure terminal\n\nevent manager applet BOUNCE_UPLINK authorization bypass\n event none\n action 1.0 syslog msg &quot;EEM: Commencing safe bounce of interface &lt;INTERFACE_NAME&gt;&quot;\n action 2.0 cli command &quot;enable&quot;\n action 3.0 cli command &quot;configure terminal&quot;\n action 4.0 cli command &quot;interface &lt;INTERFACE_NAME&gt;&quot;\n action 5.0 cli command &quot;shutdown&quot;\n action 6.0 syslog msg &quot;EEM: Interface &lt;INTERFACE_NAME&gt; administratively DOWN. Pausing...&quot;\n action 7.0 wait 5\n action 8.0 cli command &quot;interface &lt;INTERFACE_NAME&gt;&quot;\n action 9.0 cli command &quot;no shutdown&quot;\n action 9.1 cli command &quot;end&quot;\n action 9.2 syslog msg &quot;EEM: Interface &lt;INTERFACE_NAME&gt; administratively UP. Bounce complete.&quot;\nexit\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Execution_Command\"><\/span>Execution Command<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Trigger the applet directly from privileged EXEC mode:<\/p>\n<pre><code class=\"language-cisco\">Switch# event manager run BOUNCE_UPLINK\n<\/code><\/pre>\n<p><em>(Note: Your SSH session will freeze momentarily during the 5-second wait window, after which the link will recover and connectivity will resume automatically.)<\/em><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Optional_Safety_Net_Reload_Timer_Safeguard\"><\/span>Optional Safety Net: Reload Timer Safeguard<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If executing configuration changes directly on an uplink without EEM, configure a timed automatic rollback to protect against misconfiguration:<\/p>\n<pre><code class=\"language-cisco\">Switch# reload in 10\nSystem configuration has been modified. Save? [yes\/no]: no\nProceed with reload? [confirm] &lt;Enter&gt;\n\n! Perform your changes. If connection is permanently lost, the switch reloads in 10 min.\n! Once connectivity is verified safe, cancel the timer:\nSwitch# reload cancel\n<\/code><\/pre>\n<p>While administrative link bouncing resets data signaling, it does not always cut power to endpoints receiving Power over Ethernet.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Step-by-Step_Guide_Power-Cycling_PoE_Devices_Without_Data_Link_Shutdown\"><\/span>Step-by-Step Guide: Power-Cycling PoE Devices Without Data Link Shutdown<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Many edge devices\u2014including Cisco IP phones, wireless access points, and PTZ IP surveillance cameras\u2014run embedded operating systems that can experience kernel freezes or application crashes while the physical Ethernet link remains electrically up. In these cases, bouncing the data link via <code>shutdown<\/code> \/ <code>no shutdown<\/code> may leave the PoE power rails energized, failing to reboot the hardware. <\/p>\n<p>To perform a true hard power reboot without modifying VLANs, STP settings, or port security parameters, toggle the inline power delivery system directly.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Verify_Connected_PoE_Draw_and_Power_Mode\"><\/span>Step 1: Verify Connected PoE Draw and Power Mode<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Check the inline power delivery status and device consumption on the target port:<\/p>\n<pre><code class=\"language-text\">Switch# show power inline GigabitEthernet1\/0\/5\n\nInterface Admin  Oper       Power   Device              Class Max\n                            (Watts)                            \n--------- ------ ---------- ------- ------------------- ----- ----\nGi1\/0\/5   auto   on         15.4    IP Phone 8845       4     30.0\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Enter_Interface_Configuration_Mode\"><\/span>Step 2: Enter Interface Configuration Mode<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Access the specific switchport:<\/p>\n<pre><code class=\"language-text\">Switch# configure terminal\nSwitch(config)# interface GigabitEthernet1\/0\/5\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Disable_Inline_Power_Delivery\"><\/span>Step 3: Disable Inline Power Delivery<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cut the DC voltage supplied across the twisted pairs by setting the power mode to <code>never<\/code>:<\/p>\n<pre><code class=\"language-text\">Switch(config-if)# power inline never\n<\/code><\/pre>\n<p><em>The switch will cut power immediately and log the status change:<\/em><\/p>\n<pre><code class=\"language-text\">%ILPOWER-5-POWER_DISCONNECT: Interface Gi1\/0\/5: inline power disconnected\n%LINK-3-UPDOWN: Interface GigabitEthernet1\/0\/5, changed state to down\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_4_Allow_Capacitor_Discharge\"><\/span>Step 4: Allow Capacitor Discharge<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Wait 10 seconds. PoE endpoint power supply capacitors require several seconds to drain stored energy completely and ensure a true hardware cold restart.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_5_Restore_Automatic_Inline_Power_Detection\"><\/span>Step 5: Restore Automatic Inline Power Detection<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Re-enable standard IEEE 802.3af\/at\/bt resistive discovery negotiation:<\/p>\n<pre><code class=\"language-text\">Switch(config-if)# power inline auto\nSwitch(config-if)# end\n<\/code><\/pre>\n<p><em>The switch will detect the signature resistance, allocate power budget, and energize the device:<\/em><\/p>\n<pre><code class=\"language-text\">%ILPOWER-7-DETECT: Interface Gi1\/0\/5: Power Device detected: IEEE PD\n%ILPOWER-5-POWER_GRANTED: Interface Gi1\/0\/5: Power granted\n%LINK-3-UPDOWN: Interface GigabitEthernet1\/0\/5, changed state to up\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_6_Validate_Operational_Restoration\"><\/span>Step 6: Validate Operational Restoration<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Confirm that inline power is active and the endpoint has re-registered:<\/p>\n<pre><code class=\"language-text\">Switch# show power inline GigabitEthernet1\/0\/5\n<\/code><\/pre>\n<p>Sometimes, whether after a PoE power cycle or a standard administrative bounce, an interface fails to transition to <code>up\/up<\/code> and instead drops into an error state.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Troubleshooting_Guide_Resolving_Ports_Down_or_err-disabled_After_a_Bounce\"><\/span>Troubleshooting Guide: Resolving Ports Down or <code>err-disabled<\/code> After a Bounce<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When an interface remains down after issuing <code>no shutdown<\/code>, the switch has typically detected a Layer 2 policy violation or a Layer 1 signaling failure. Follow this systematic diagnostic sequence to identify and correct the underlying fault.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Identify_the_Interface_Operational_State\"><\/span>Step 1: Identify the Interface Operational State<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Query the switch port summary to identify whether the port is disconnected or error-disabled:<\/p>\n<pre><code class=\"language-text\">Switch# show interfaces GigabitEthernet1\/0\/12 status\n\nPort      Name               Status       Vlan       Duplex  Speed Type\nGi1\/0\/12  Uplink-Distribution err-disabled 1          auto    auto  10\/100\/1000BaseTX\n<\/code><\/pre>\n<p>If the status displays <code>notconnect<\/code>, the switch is administratively active but detects no electrical carrier. Verify physical cabling, patch panel punch-downs, SFP seating, and endpoint power. If the status displays <code>err-disabled<\/code>, proceed to Step 2.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Identify_the_Root_Cause_of_the_Error\"><\/span>Step 2: Identify the Root Cause of the Error<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Execute the diagnostic command for error-disabled interfaces to inspect the triggering mechanism:<\/p>\n<pre><code class=\"language-text\">Switch# show interfaces status err-disabled\n\nPort      Name               Status       Reason               Err-disabled Vlans\nGi1\/0\/12  Uplink-Distribution err-disabled bpduguard\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Remediate_Common_Root_Causes\"><\/span>Step 3: Remediate Common Root Causes<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Before re-enabling the interface, correct the operational violation that triggered the protection mechanism:<\/p>\n<ul>\n<li><strong>BPDU Guard (<code>bpduguard<\/code>):<\/strong> A switch, rogue router, or virtualization host sending Spanning Tree Bridge Protocol Data Units was detected on a port configured with <code>spanning-tree bpduguard enable<\/code> (or PortFast).  <\/li>\n<li><em>Fix:<\/em> Disconnect the unmanaged switch\/device or disable BPDU Guard on trunk uplinks: <code>no spanning-tree bpduguard enable<\/code>.<\/li>\n<li><strong>Port Security Violation (<code>psecure-violation<\/code>):<\/strong> A newly connected device presented a MAC address that exceeded the configured threshold or violated sticky bindings.  <\/li>\n<li><em>Fix:<\/em> Clear unauthorized MAC entries or update the security table: <code>clear port-security dynamic interface Gi1\/0\/12<\/code>.<\/li>\n<li><strong>UniDirectional Link Detection (<code>udld<\/code>):<\/strong> The switch detected that fiber transmit (TX) traffic is flowing, but receive (RX) continuity is broken.  <\/li>\n<li><em>Fix:<\/em> Inspect optical patch cables, swap TX\/RX pairs, or clean transceiver optics.<\/li>\n<li><strong>Speed\/Duplex Mismatch:<\/strong> Incompatible manual speed settings prevent physical framing sync.  <\/li>\n<li><em>Fix:<\/em> Align both ends to <code>speed auto<\/code> and <code>duplex auto<\/code>.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Step_4_Clear_the_Err-Disabled_State_and_Re-enable\"><\/span>Step 4: Clear the Err-Disabled State and Re-enable<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Once the root cause is resolved, reset the port&#8217;s internal state machine by toggling the administrative state as outlined in our CLI guide above:<\/p>\n<pre><code class=\"language-text\">Switch# configure terminal\nSwitch(config)# interface GigabitEthernet1\/0\/12\nSwitch(config-if)# shutdown\nSwitch(config-if)# no shutdown\nSwitch(config-if)# end\n<\/code><\/pre>\n<h3><span class=\"ez-toc-section\" id=\"Step_5_Configure_Automatic_Err-Disable_Recovery_Best_Practice\"><\/span>Step 5: Configure Automatic Err-Disable Recovery (Best Practice)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>To prevent network engineers from having to log in manually whenever a transient policy violation occurs, configure automated recovery timers in global configuration mode:<\/p>\n<pre><code class=\"language-cisco\">Switch(config)# errdisable recovery cause bpduguard\nSwitch(config)# errdisable recovery cause psecure-violation\nSwitch(config)# errdisable recovery cause udld\nSwitch(config)# errdisable recovery cause link-flap\nSwitch(config)# errdisable recovery interval 300\nSwitch(config)# end\n<\/code><\/pre>\n<p>This configuration directs the switch operating system to attempt an automatic recovery every 300 seconds (5 minutes), re-enabling the port automatically if the offending condition has cleared.<\/p>\n<hr \/>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Bouncing a port on a Cisco switch is an indispensable troubleshooting technique that resets Layer 1 signaling and Layer 2 state machines without requiring physical access to equipment racks. For routine endpoint issues, a straightforward <code>shutdown<\/code> and <code>no shutdown<\/code> cycle cleanly clears dynamic MAC tables and forces client DHCP and 802.1X renegotiation. When working across remote connections, using Cisco IOS EEM scripts prevents accidental lockouts, while cycling inline PoE power provides a targeted cold reboot for frozen IP phones, cameras, and access points without affecting data port logic. Finally, combining diagnostic commands with automated <code>errdisable recovery<\/code> ensures that interfaces return to service quickly and stay resilient against unexpected network disruptions.<\/p>\n<div class='sfsi_Sicons' style='width: 100%; display: inline-block; vertical-align: middle; text-align:left'><div style='margin:0px 8px 0px 0px; line-height: 24px'><span>Please follow and like us:<\/span><\/div><div class='sfsi_socialwpr'><div class='sf_fb_share sf_icon' style='text-align:left;vertical-align: middle;'><a href='https:\/\/www.facebook.com\/sharer\/sharer.php?u=https%3A%2F%2Fcciedump.spoto.net%2Fblog%2Fhow-to-bounce-port-on-cisco-switch_24506.html' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Facebook Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/fbshare_bck.png'  \/><\/a><\/div><div class='sf_twiter sf_icon' style='display: inline-block;vertical-align: middle;width: auto;margin-left: 7px;'>\r\n\t\t\t\t\t\t<a target='_blank' href='https:\/\/twitter.com\/intent\/tweet?text=How+to+Bounce+Port+on+Cisco+Switch+https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html'style='display:inline-block' >\r\n\t\t\t\t\t\t\t<img data-pin-nopin= true width='auto' class='sfsi_wicon' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/visit_icons\/en_US_Tweet.svg' alt='Tweet' title='Tweet' >\r\n\t\t\t\t\t\t<\/a>\r\n\t\t\t\t\t<\/div><div class='sf_pinit sf_icon' style='text-align:left;vertical-align: middle;float:left;line-height: 33px;width:auto;margin: 0 -2px;'><a href='#'  onclick='sfsi_pinterest_modal_images(event,\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\",\"How to Bounce Port on Cisco Switch\")' style='display:inline-block;'  > <img class='sfsi_wicon'  data-pin-nopin='true' width='auto' height='auto' alt='fb-share-icon' title='Pin Share' src='https:\/\/cciedump.spoto.net\/blog\/wp-content\/plugins\/ultimate-social-media-icons\/images\/share_icons\/Pinterest_Save\/en_US_save.svg'  \/><\/a><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>In enterprise campus and data center networking, bouncing a switch port is one of the most fundamental operational tasks performed by network administrators. Whether restoring connectivity to a frozen IP camera, clearing stale MAC address entries after a patch cable swap, or re-initiating 802.1X port authentication for a stubborn workstation, cycling an interface resets the&#8230; &raquo; <a class=\"read-more-link\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\">read more<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,608],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Bounce Port on Cisco Switch - SPOTO Official Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Bounce Port on Cisco Switch - SPOTO Official Blog\" \/>\n<meta property=\"og:description\" content=\"In enterprise campus and data center networking, bouncing a switch port is one of the most fundamental operational tasks performed by network administrators. Whether restoring connectivity to a frozen IP camera, clearing stale MAC address entries after a patch cable swap, or re-initiating 802.1X port authentication for a stubborn workstation, cycling an interface resets the... &raquo; read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\" \/>\n<meta property=\"og:site_name\" content=\"SPOTO Official Blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-16T03:26:31+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"SPOTO \u7f16\u8f91\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\",\"name\":\"SPOTO Club\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg\",\"caption\":\"SPOTO Club\"},\"logo\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\"},\"description\":\"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205\",\"sameAs\":[\"https:\/\/cciedump.spoto.net\/\"]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/\",\"name\":\"SPOTO Official Blog\",\"description\":\"Focus on Online IT Training for 20+ Years\",\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#webpage\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\",\"name\":\"How to Bounce Port on Cisco Switch - SPOTO Official Blog\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#website\"},\"datePublished\":\"2026-11-16T03:26:31+00:00\",\"dateModified\":\"2026-11-16T03:26:31+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cciedump.spoto.net\/blog\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Bounce Port on Cisco Switch\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#article\",\"isPartOf\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#webpage\"},\"author\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\"},\"headline\":\"How to Bounce Port on Cisco Switch\",\"datePublished\":\"2026-11-16T03:26:31+00:00\",\"dateModified\":\"2026-11-16T03:26:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#webpage\"},\"wordCount\":1683,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638\"},\"articleSection\":[\"CCNA Certification\",\"Cisco Certification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1\",\"name\":\"SPOTO \u7f16\u8f91\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/cciedump.spoto.net\/blog\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"contentUrl\":\"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155\",\"caption\":\"SPOTO \u7f16\u8f91\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Bounce Port on Cisco Switch - SPOTO Official Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html","og_locale":"en_US","og_type":"article","og_title":"How to Bounce Port on Cisco Switch - SPOTO Official Blog","og_description":"In enterprise campus and data center networking, bouncing a switch port is one of the most fundamental operational tasks performed by network administrators. Whether restoring connectivity to a frozen IP camera, clearing stale MAC address entries after a patch cable swap, or re-initiating 802.1X port authentication for a stubborn workstation, cycling an interface resets the... &raquo; read more","og_url":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html","og_site_name":"SPOTO Official Blog","article_published_time":"2026-11-16T03:26:31+00:00","twitter_card":"summary_large_image","twitter_misc":{"Written by":"SPOTO \u7f16\u8f91","Est. reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Person","Organization"],"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638","name":"SPOTO Club","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/uploads\/2020\/03\/spoto-facemask-96x96.jpg","caption":"SPOTO Club"},"logo":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo"},"description":"SPOTO is an excellent leader in IT certification training for 20+ years. We offer 100% real Cisco CCNA, CCNP exam dumps, CCIE Lab study materials, PMP, CISA, CISM, AWS, Palo Alto, and other IT exam dumps. We have helped thousands of candidates around the world to pass their IT exams on the first try! As the first-class online IT training organization in China, SPOTO cooperates with many giant Internet companies in China like Tencent, Baidu, and Alibaba. What\u2019s more, we have won lots of awards in IT education training such as \u201cTop Ten Influential Brands In Online Education Industry\u201d given by Baidu, \u201cOfficial IT Online Training Organization\u201d awarded by Tencent Class, etc. Join us: https:\/\/cciedump.spoto.net\/ Contact us: E-mail: support@spoto.net Phone \/ WhatsApp: +86 18344981205","sameAs":["https:\/\/cciedump.spoto.net\/"]},{"@type":"WebSite","@id":"https:\/\/cciedump.spoto.net\/blog\/#website","url":"https:\/\/cciedump.spoto.net\/blog\/","name":"SPOTO Official Blog","description":"Focus on Online IT Training for 20+ Years","publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cciedump.spoto.net\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#webpage","url":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html","name":"How to Bounce Port on Cisco Switch - SPOTO Official Blog","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#website"},"datePublished":"2026-11-16T03:26:31+00:00","dateModified":"2026-11-16T03:26:31+00:00","breadcrumb":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cciedump.spoto.net\/blog"},{"@type":"ListItem","position":2,"name":"How to Bounce Port on Cisco Switch"}]},{"@type":"Article","@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#article","isPartOf":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#webpage"},"author":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1"},"headline":"How to Bounce Port on Cisco Switch","datePublished":"2026-11-16T03:26:31+00:00","dateModified":"2026-11-16T03:26:31+00:00","mainEntityOfPage":{"@id":"https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#webpage"},"wordCount":1683,"commentCount":0,"publisher":{"@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/25594d4796697ccb1ef63d55c269c638"},"articleSection":["CCNA Certification","Cisco Certification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/cciedump.spoto.net\/blog\/how-to-bounce-port-on-cisco-switch_24506.html#respond"]}]},{"@type":"Person","@id":"https:\/\/cciedump.spoto.net\/blog\/#\/schema\/person\/4edd6074d9632c14eda17a2205a88dd1","name":"SPOTO \u7f16\u8f91","image":{"@type":"ImageObject","@id":"https:\/\/cciedump.spoto.net\/blog\/#personlogo","inLanguage":"en-US","url":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","contentUrl":"https:\/\/cciedump.spoto.net\/blog\/wp-content\/litespeed\/avatar\/f525ded90e4ff384a19ebdbe47c80d22.jpg?ver=1794560155","caption":"SPOTO \u7f16\u8f91"}}]}},"_links":{"self":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24506"}],"collection":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/comments?post=24506"}],"version-history":[{"count":0,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/posts\/24506\/revisions"}],"wp:attachment":[{"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/media?parent=24506"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/categories?post=24506"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cciedump.spoto.net\/blog\/wp-json\/wp\/v2\/tags?post=24506"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}